Lucene search
+L

2326 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2012/10/10 12:00 a.m.•5 views

CVE-2012-3040: Improper Neutralization of Input During Web Page Generation

Cross-site scripting XSS vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI...

4.3CVSS7.3AI score0.02556EPSS
SaveExploits1References2
OpenVAS
OpenVAS
•added 2012/10/10 12:00 a.m.•156 views

Siemens SIMATIC S7-1200 PLC 'web server' Component XSS Vulnerability (SSA-279823)

Siemens SIMATIC S7-1200 devices are prone to a cross-site scripting XSS vulnerability because they fail to properly sanitize user-supplied input. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective...

4.3CVSS7.1AI score0.02556EPSS
SaveExploits1References3
OpenVAS
OpenVAS
•added 2012/10/10 12:00 a.m.•96 views

Siemens SIMATIC S7-1200 PLC Detection

Detection of Siemens SIMATIC S7-1200 PLC. This VT has been deprecated and replaced by the VT SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...

7AI score
SaveExploits0
Positive Technologies
Positive Technologies
•added 2012/10/08 12:00 a.m.•7 views

PT-2012-1202

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 PLCs versions 2.x through 3.0.1 Description The issue is related to a lack of protection measures for the web server, allowing for the exploitation of a cross-site scripting XSS vulnerability. This vulnerability enables...

4.3CVSS0.02556EPSS
SaveExploits1References10
NVD
NVD
•added 2012/09/25 11:07 a.m.•34 views

CVE-2012-3037

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...

4.3CVSS6.5AI score0.01472EPSS
SaveExploits1References3
Prion
Prion
•added 2012/09/25 11:07 a.m.•22 views

Code injection

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...

4.3CVSS7AI score0.01472EPSS
SaveExploits1References3Affected Software9
Cvelist
Cvelist
•added 2012/09/25 10:00 a.m.•39 views

CVE-2012-3037

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...

6.4AI score0.01472EPSS
SaveExploits1References3
CVE
CVE
•added 2012/09/25 10:00 a.m.•97 views

CVE-2012-3037

The CVE-2012-3037 vul nerability affects Siemens SIMATIC S7-1200 PLCs (2.x) where the private key of the SIMATIC CONTROLLER Certification Authority certificate is not protected in HTTPS storage. This allows remote attackers to forge a certificate and spoof the S7-1200 web server. Affected product...

4.3CVSS6.6AI score0.01472EPSS
SaveExploits1References3Affected Software1
Positive Technologies
Positive Technologies
•added 2012/09/25 12:00 a.m.•6 views

PT-2012-4454

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 version 2.x Description The issue concerns the Siemens SIMATIC S7-1200 PLC, where the private key of the SIMATIC CONTROLLER Certification Authority certificate is not properly protected. This allows remote attackers to...

4.3CVSS0.01472EPSS
SaveExploits1References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2012/09/25 12:00 a.m.•4 views

CVE-2012-3037: Improper Certificate Validation

The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate...

4.3CVSS7.3AI score0.01472EPSS
SaveExploits1References2
OpenVAS
OpenVAS
•added 2012/09/20 12:00 a.m.•65 views

Siemens SIMATIC S7-1200 SSL Private Key Reuse Spoofing Vulnerability (SSA-240718)

Siemens SIMATIC S7-1200 devices are prone to a security vulnerability that may allow attackers to spoof SSL certificates. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders...

4.3CVSS7.1AI score0.01472EPSS
SaveExploits1References2
NVD
NVD
•added 2012/07/31 10:45 a.m.•23 views

CVE-2012-3017

Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets...

7.8CVSS6.9AI score0.03464EPSS
SaveExploits0References3
NVD
NVD
•added 2012/07/31 10:45 a.m.•27 views

CVE-2012-3016

Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets...

7.8CVSS6.8AI score0.03464EPSS
SaveExploits0References3
Prion
Prion
•added 2012/07/31 10:45 a.m.•26 views

Code injection

Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets...

7.8CVSS7.4AI score0.03464EPSS
SaveExploits0References3Affected Software1
Prion
Prion
•added 2012/07/31 10:45 a.m.•28 views

Code injection

Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets...

7.8CVSS7.3AI score0.03464EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
•added 2012/07/31 10:00 a.m.•35 views

CVE-2012-3016

Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service defect-mode transition and service outage via crafted ICMP packets...

6.7AI score0.03464EPSS
SaveExploits0References3
CVE
CVE
•added 2012/07/31 10:00 a.m.•62 views

CVE-2012-3017

Summary: CVE-2012-3017 affects Siemens SIMATIC S7-400 PN CPU devices running firmware 5.x. The vulnerability allows remote attackers to trigger a denial of service (defect-mode transition and service outage) by sending malformed HTTP traffic or malformed IP packets. The publicly provided document...

7.8CVSS7.1AI score0.03464EPSS
SaveExploits0References3Affected Software4
CVE
CVE
•added 2012/07/31 10:00 a.m.•68 views

CVE-2012-3016

The vulnerability CVE-2012-3016 affects Siemens SIMATIC S7-400 PN CPU devices running firmware 6 up to (but not including) 6.0.3. It allows remote attackers to cause a DoS by sending crafted ICMP packets, potentially forcing the PLC into defect mode with a manual reset needed to restore operation...

7.8CVSS6.9AI score0.03464EPSS
SaveExploits0References3Affected Software6
Cvelist
Cvelist
•added 2012/07/31 10:00 a.m.•38 views

CVE-2012-3017

Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service defect-mode transition and service outage via 1 malformed HTTP traffic or 2 malformed IP packets...

6.9AI score0.03464EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2012/07/31 12:00 a.m.•6 views

PT-2012-4441

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x Description The issue allows remote attackers to cause a denial of service, resulting in a defect-mode transition and service outage. This can be achieved via malformed HTTP traffic or...

7.8CVSS0.03464EPSS
SaveExploits0References4
Rows per page
Query Builder