Lucene search
+L

607 matches found

CNVD
CNVD
added 2018/08/27 12:0 a.m.4 views

Multiple BD products improperly certified for loopholes

BD Alaris GS, etc. are different series of medical syringe pump products from BD USA. The improper authentication vulnerability exists in multiple BD products and stems from the software failing to perform authentication for functions that require authentication. A remote attacker could use this...

9.4CVSS9.8AI score0.03058EPSS
SaveExploits0References1
CVE
CVE
added 2018/08/13 10:0 p.m.69 views

CVE-2018-14781

CVE-2018-14781 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps (e.g., MMT-508, MMT-511/512/712, MMT-515/723, MMT-522/723 REAL-TIME, MMT-551/751, etc.). Root cause: Authentication Bypass by Capture-replay when paired with a remote controller with non-default easy bol...

5.3CVSS5.2AI score0.00712EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2018/08/13 10:0 p.m.55 views

CVE-2018-10634

CVE-2018-10634 affects Medtronic MiniMed MMT-500/MMT-503 Remote Controllers and related pumps. The vulnerability stems from cleartext transmission of sensitive information between the pump and wireless accessories, enabling potential information disclosure (e.g., device serial numbers). A separat...

5.3CVSS5.1AI score0.00474EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/08/13 10:0 p.m.28 views

CVE-2018-14781 Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay

Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled non-default, are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them t...

5.3CVSS5.3AI score0.00712EPSS
SaveExploits0References3
NVD
NVD
added 2018/08/13 9:47 p.m.22 views

CVE-2018-10634

Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers...

5.3CVSS5.2AI score0.00474EPSS
SaveExploits0References3
Prion
Prion
added 2018/08/13 9:47 p.m.19 views

Information disclosure

Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G communications between the pump and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker cou...

2.9CVSS5.2AI score0.00474EPSS
SaveExploits0References2
Schneier on Security
Schneier on Security
added 2018/07/13 11:18 a.m.30 views

Gas Pump Hack

This is weird: Police in Detroit are looking for two suspects who allegedly managed to hack a gas pump and steal over 600 gallons of gasoline, valued at about $1,800. The theft took place in the middle of the day and went on for about 90 minutes, with the gas station attendant unable to thwart th...

0.6AI score
SaveExploits0
HackRead
HackRead
added 2018/07/07 1:20 p.m.59 views

Crooks hack gas station fuel pump to steal 600 gallons of gas

By Uzair Amir We have read about credit card skimmers at ATMs or This is a post from HackRead.com Read the original post: Crooks hack gas station fuel pump to steal 600 gallons of gas...

1.8AI score
SaveExploits0
Krebs on Security
Krebs on Security
added 2018/06/26 5:59 p.m.25 views

How to Avoid Card Skimmers at the Pump

Previous stories here on the proliferation of card-skimming devices hidden inside fuel pumps have offered a multitude of security tips for readers looking to minimize their chances of becoming the next victim, such as favoring filling stations that use security cameras and tamper-evident tape on...

6.7AI score
SaveExploits0
Openbugbounty
Openbugbounty
added 2018/03/25 7:21 a.m.13 views

grit-pump.com XSS vulnerability

Open Bug Bounty ID: OBB-588493 Description| Value ---|--- Affected Website:| grit-pump.com Open Bug Bounty Program:| Create your bounty program now. It's open and free. Vulnerable Application:| Custom Code Vulnerability Type:| XSS Cross Site Scripting / CWE-79 CVSSv3 Score:| 6.1...

6.2AI score
SaveExploits0
OSV
OSV
added 2018/02/15 10:29 a.m.5 views

CVE-2017-12720

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

8.1CVSS5.8AI score0.01851EPSS
SaveExploits0References2
NVD
NVD
added 2018/02/15 10:29 a.m.25 views

CVE-2017-12718

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on t...

8.1CVSS8.5AI score0.12785EPSS
SaveExploits4References4
Prion
Prion
added 2018/02/15 10:29 a.m.17 views

Improper access control

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

6.8CVSS8.1AI score0.01851EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2018/02/15 10:29 a.m.7 views

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications...

3.7CVSS5.8AI score0.00975EPSS
SaveExploits0References2
OSV
OSV
added 2018/02/15 10:29 a.m.6 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS5.8AI score0.00673EPSS
SaveExploits0References2
NVD
NVD
added 2018/02/15 10:29 a.m.24 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS6.4AI score0.00673EPSS
SaveExploits0References2
NVD
NVD
added 2018/02/15 10:29 a.m.21 views

CVE-2017-12725

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...

6.8CVSS6.3AI score0.00834EPSS
SaveExploits0References2
OSV
OSV
added 2018/02/15 10:29 a.m.7 views

CVE-2017-12726

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...

7.3CVSS5.8AI score0.01082EPSS
SaveExploits0References2
OSV
OSV
added 2018/02/15 10:29 a.m.5 views

CVE-2017-12722

An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the...

5.3CVSS5.8AI score0.02415EPSS
SaveExploits0References3
NVD
NVD
added 2018/02/15 10:29 a.m.27 views

CVE-2017-12724

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...

8.1CVSS8.1AI score0.01323EPSS
SaveExploits0References2
Rows per page