607 matches found
CVE-2020-2969
Vulnerability in the Data Pump component of Oracle Database Server. Supported versions that are affected are 11.2.0.4, 12.1.0.2, 12.2.0.1, 18c and 19c. Difficult to exploit vulnerability allows high privileged attacker having DBA role account privilege with network access via Oracle Net to...
CVE-2020-2969
CVE-2020-2969 affects Oracle Database Server’s Data Pump component. Affected versions: 11.2.0.4, 12.1.0.2, 12.2.0.1, 18c, and 19c. The issue is exploitable by a high-privilege DBA account with network access via Oracle Net, potentially allowing takeover of Data Pump. CVSSv3.1 base score is 6.6 (C...
Unspecified Vulnerability in Oracle Database Server Data Pump Component
Oracle Database Server is an object-relational database management system that provides an open, comprehensive, and integrated approach to information management.Data Pump is the data and metadata migration component. A security vulnerability exists in the Data Pump component in Oracle Database...
Cryptocurrency Pump and Dump Scams
Really interesting research: "An examination of the cryptocurrency pump and dump ecosystem": Abstract: The surge of interest in cryptocurrencies has been accompanied by a proliferation of fraud. This paper examines pump and dump schemes. The recent explosion of nearly 2,000 cryptocurrencies in an...
Baxter Spectrum WBM Trust Management Issues Vulnerability (CNVD-2021-21077)
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum is vulnerable to a trust management issue that could be exploited by an attacke...
Unspecified Vulnerability in Baxter Spectrum WBM
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability. An attacker could exploit this vulnerability to...
Unspecified Vulnerability in Baxter Spectrum WBM (CNVD-2021-21076)
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. A security vulnerability exists in the Baxter Spectrum WBM that can be exploited by an attacker to gain access to F...
Baxter Spectrum WBM Trust Management Issues Vulnerability
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability that can be exploited by an attacker to run Telnet...
Insulet Omnipod Insulin Management System Access Control Error Vulnerability
Insulet Omnipod Insulin Management System is an insulin management system from Insulet USA. An Access Control Error vulnerability exists in the Insulet Omnipod Insulin Management System, which arises from a failure of the wireless RF communication protocol to properly implement authentication or...
Cybercriminals Fill Up on Gas Pump Transaction Scams Ahead of Oct. Deadline
Gas stations are gearing up for a major change in credit-card fraud liability in October, when they will find themselves on the hook for card-skimming attacks at the pump. In the meantime though, cybercriminals will be targeting pay-at-the-pump point-of-sale mechanisms with a vengeance, researche...
Hidden Cam Above Bluetooth Pump Skimmer
Tiny hidden spy cameras are a common sight at ATMs that have been tampered with by crooks who specialize in retrofitting the machines with card skimmers. But until this past week I'd never heard of hidden cameras being used at gas pumps in tandem with Bluetooth-based card skimming devices...
GLSA-201911-02 : pump: User-assisted execution of arbitrary code
The remote host is affected by the vulnerability described in GLSA-201911-02 pump: User-assisted execution of arbitrary code It was discovered that there was an arbitrary code execution vulnerability in the pump DHCP/BOOTP client. Impact : A remote attacker, by enticing a user to connect to a...
pump: User-assisted execution of arbitrary code
Background BOOTP and DHCP client for automatic IP configuration. Description It was discovered that there was an arbitrary code execution vulnerability in the pump DHCP/BOOTP client. Impact A remote attacker, by enticing a user to connect to a malicious server, could cause the execution of...
Debian: Security Advisory (DLA-1908-1)
The remote host is missing an update for the Debian SPDX-FileCopyrightText: 2019 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
Debian DLA-1908-1 : pump security update
It was discovered that there was an arbitrary code execution vulnerability in the pump BOOTP and DHCP client. When copying the body of the server response, the ethernet packet length could be forged leading to being able to overwrite up to 'ETHFRAMELEN - sizeofipHdr - sizeofudpHdr - sizeofbresp'...
[SECURITY] [DLA 1908-1] pump security update
Package : pump Version : 0.8.24-7+deb8u1 Debian Bug : 933674 It was discovered that there was an arbitrary code execution vulnerability in the pump BOOTP and DHCP client. When copying the body of the server response, the ethernet packet length could be forged leading to being able to overwrite up...
DLA-1908-1 pump - security update
Bulletin has no description...
Hackers Made an App That Kills to Prove a Point
Medtronic and the FDA left an insulin pump with a potentially deadly vulnerability on the market—until researchers who found the flaw showed how bad it could be...
CVE-2019-10964
Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker...
Max-Severity Bug in Infusion Pump Gateway Puts Lives at Risk
Researchers have disclosed two separate vulnerabilities within the Becton Dickinson Alaris Gateway Workstation for medical infusion pumps in hospitals, one carrying a critical rating of 10 out of 10 on the CVSS v.3 severity scale. Alaris Gateway Workstations power, monitor and control infusion...