1178 matches found
Device Status Query Detected (Critical)
A status query has been sent to the device, which might indicate a reconnaissance activity. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503185...
OSV-2025-289 Stack-buffer-overflow in ot::Cli::Utils::OutputLine
OSS-Fuzz report: https://bugs.chromium.org/p/oss-fuzz/issues/detail?id=411460530 Crash type: Stack-buffer-overflow READ Crash state: ot::Cli::Utils::OutputLine ot::Cli::Dns::HandleDnsRecordResponse ot::Dns::Client::FinalizeQuery...
Firmware Version Change Detected (Medium)
Changes in the controller firmware represent a major change in the behavior of the device and usually cause a temporary interruption of operations. An attacker could use firmware changes to add malicious code to the controller, causing it to perform harmful operations which are hard to detect. Th...
Firmware Version Change Detected (High)
Changes in the controller firmware represent a major change in the behavior of the device and usually cause a temporary interruption of operations. An attacker could use firmware changes to add malicious code to the controller, causing it to perform harmful operations which are hard to detect. Th...
Hitachi Energy's RTU500 series Missing synchronization (CVE-2025-1445)
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are...
Hitachi Energy's RTU500 series NULL Pointer Deference (CVE-2024-10037)
A vulnerability exists in the RTU500 web server com- ponent that can cause a denial of service to the RTU500 CMU application if a specially crafted mes- sage sequence is executed on a WebSocket connec- tion. An attacker must be properly authenticated and the test mode function of RTU500 must be...
Microhard 3G/4G Cellular Ethernet and Serial Gateway External Control of File Name or Path (ZSL-2018-5484)
The system backup configuration file 'IPn4G.config' in '/' directory or its respective name based on the model name including the similar files in '/www/cgi-bin/system.conf', '/tmp' and the cli.conf in '/etc/mcli/' can be downloaded by an authenticated attacker in certain circumstances. This will...
Schneider Electric Active Devices Detection
The current plugin identifies Schneider devices that are still under active support. Schneider Lifecycle Statuses: - Active: Most current offering within a product category. - End of Life: Discontinued date announced - actively execute migrations and last time buys. Product generally orderable...
Siemens SCALANCE LPE9403 Improper Check For Dropped Privileges (CVE-2025-27396)
Affected devices do not properly limit the elevation of privileges required to perform certain valid functionality. This could allow an authenticated lowly-privileged remote attacker to escalate their privileges. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-1500 TM MFP Buffer Access with Incorrect Length Value (CVE-2024-42154)
In the Linux kernel, the following vulnerability has been resolved: tcpmetrics: validate source addr length I don't see anything checking that TCPMETRICSATTRSADDRIPV4 is at least 4 bytes long, and the policy doesn't have an entry for this attribute at all neither does it for IPv6 but v6 is manual...
Siemens SIMATIC S7-1500 TM MFP Double Free (CVE-2024-41046)
In the Linux kernel, the following vulnerability has been resolved: net: ethernet: lantiqetop: fix double free in detach The number of the currently released descriptor is never incremented which results in the same skb being released multiple times. This plugin only works with Tenable.ot. Please...
Siemens SCALANCE LPE9403 Improper Neutralization of Special Elements Used in an OS Command (CVE-2025-27392)
Affected devices do not properly sanitize user input when creating new VXLAN configurations. This could allow an authenticated highly- privileged remote attacker to execute arbitrary code on the device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-...
Siemens SCALANCE M-800 and SC-600 Families Partial String Comparison (CVE-2025-23384)
A remote attacker needs to have access to a valid certificate in order to perform a successful attack. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SCALANCE X-200RNA Switch Devices Cryptographic Issues (CVE-2015-0285)
The ssl3clienthello function in s3clnt.c in OpenSSL 1.0.2 before 1.0.2a does not ensure that the PRNG is seeded before proceeding with a handshake, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by sniffing the network and then conducting a brute-force...
Siemens SCALANCE X-200RNA Switch Devices Improper Certificate Validation (CVE-2019-1552)
OpenSSL has internal defaults for a directory tree where it can find a configuration file as well as certificates used for verification in TLS. This directory is most commonly referred to as OPENSSLDIR, and is configurable with the --prefix / --openssldir configuration options. For OpenSSL versio...
Siemens SCALANCE X-200RNA Switch Devices Resource Management Errors (CVE-2015-1788)
The BNGF2mmodinv function in crypto/bn/bngf2m.c in OpenSSL before 0.9.8s, 1.0.0 before 1.0.0e, 1.0.1 before 1.0.1n, and 1.0.2 before 1.0.2b does not properly handle ECParameters structures in which the curve is over a malformed binary polynomial field, which allows remote attackers to cause a...
Siemens SIMATIC S7-1500 and S7-1200 Use After Free (CVE-2021-22901)
curl 7.75.0 through 7.76.1 suffers from a use-after-free vulnerability resulting in already freed memory being used when a TLS 1.3 session ticket arrives over a connection. A malicious server can use this in rare unfortunate circumstances to potentially reach remote code execution in the client...
Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2015-1789)
The X509cmptime function in crypto/x509/x509vfy.c in OpenSSL before 0.9.8zg, 1.0.0 before 1.0.0s, 1.0.1 before 1.0.1n, and 1.0.2 before 1.0.2b allows remote attackers to cause a denial of service out-of- bounds read and application crash via a crafted length field in ASN1TIME data, as demonstrate...
Siemens SCALANCE X-200RNA Switch Devices Use After Free (CVE-2015-6564)
Use-after-free vulnerability in the mmanswerpamfreectx function in monitor.c in sshd in OpenSSH before 7.0 on non-OpenBSD platforms might allow local users to gain privileges by leveraging control of the sshd uid to send an unexpectedly early MONITORREQPAMFREECTX request. This plugin only works...
Siemens SCALANCE X-200RNA Switch Devices Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2016-0799)
The fmtstr function in crypto/bio/bprint.c in OpenSSL 1.0.1 before 1.0.1s and 1.0.2 before 1.0.2g improperly calculates string lengths, which allows remote attackers to cause a denial of service overflow and out-of-bounds read or possibly have unspecified other impact via a long string, as...