Siemens SCALANCE LPE9403 Improper Neutralization of Special Elements Used in an OS Command (CVE-2025-27392)

🗓️ 17 Mar 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 9 Views

Siemens SCALANCE LPE9403 is vulnerable to OS command injection allowing remote code execution.

Related
Refs
Code
ReporterTitlePublishedViews
Family
bdu_fstec
BDU FSTEC
The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software lies in the lack of measures to neutralize special elements, allowing attackers to execute arbitrary code.
18 Mar 202500:00
bdu_fstec
circl
Circl
CVE-2025-27392
11 Mar 202511:35
circl
cnnvd
CNNVD
Siemens SCALANCE LPE9403 操作系统命令注入漏洞
11 Mar 202500:00
cnnvd
cve
CVE
CVE-2025-27392
11 Mar 202509:48
cve
cvelist
Cvelist
CVE-2025-27392
11 Mar 202509:48
cvelist
euvd
EUVD
EUVD-2025-7762
3 Oct 202520:07
euvd
ncsc
NCSC
Vulnerabilities fixed in Siemens products
11 Mar 202512:30
ncsc
nvd
NVD
CVE-2025-27392
11 Mar 202510:15
nvd
osv
OSV
CVE-2025-27392
11 Mar 202510:15
osv
redhatcve
RedhatCVE
CVE-2025-27392
13 Mar 202516:58
redhatcve
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503138);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/02/14");

  script_cve_id("CVE-2025-27392");
  script_xref(name:"ICSA", value:"25-072-06");

  script_name(english:"Siemens SCALANCE LPE9403 Improper Neutralization of Special Elements Used in an OS Command (CVE-2025-27392)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"Affected devices do not properly sanitize user input when creating new
VXLAN configurations.  This could allow an authenticated highly-
privileged remote attacker to execute arbitrary code on the device.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-075201.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109976925/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-06");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

- SCALANCE LPE9403 (6GK5998-3GS00-2AC2): Update to V4.0 or later version.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To
operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens'
operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-075201 in HTML and CSAF.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-27392");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(78);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/03/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/03/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/17");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_lpe9403_firmware:4.0");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_lpe9403_firmware:4.0" :
        {"versionEndExcluding" : "4.0", "family" : "SCALANCE", "orderNumbers" : ['6GK5998-3GS00-2AC2']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

14 Feb 2026 00:00Current
6.2Medium risk
Vulners AI Score6.2
CVSS 3.17.2
CVSS 48.6
EPSS0.00715
SSVC
9