Lucene search
+L

Siemens SCALANCE X-200RNA Switch Devices Improper Certificate Validation (CVE-2019-1552)

🗓️ 13 Mar 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 9 Views

Siemens SCALANCE X-200RNA Switch Devices have improper certificate validation issues affecting OpenSSL.

Related
Refs
Code
ReporterTitlePublishedViews
Family
IBM Security Bulletins
Security Bulletin: Multiple vulnerabilities in OpenSSL affect IBM Tivoli Netcool System Service Monitors/Application Service Monitors (CVE-2018-5407,CVE-2020-1967,CVE-2018-0734,CVE-2019-1563,CVE-2019-1549,CVE-2019-1552,CVE-2019-1559,CVE-2018-0735)
15 Dec 202020:13
ibm
IBM Security Bulletins
Security Bulletin: OpenSSL vulnerability affects IBM Rational Team Concert
12 Feb 202016:09
ibm
IBM Security Bulletins
Security Bulletin: OpenSSL vulnerabilities affect IBM Spectrum Control (formerly Tivoli Storage Productivity Center)
22 Feb 202220:10
ibm
IBM Security Bulletins
Security Bulletin: WebSphere MQ for HP NonStop Server is affected by OpenSSL vulnerability CVE-2019-1552
14 Jan 202015:56
ibm
IBM Security Bulletins
Security Bulletin: Vulnerabilities in OpenSSL affect IBM Rational ClearQuest (CVE-2019-1552, CVE-2019-1563)
30 Mar 202002:56
ibm
IBM Security Bulletins
Security Bulletin: Vulnerability in OpenSSL affects IBM Rational ClearCase (CVE-2019-1552, CVE-2019-1563)
27 Mar 202014:21
ibm
IBM Security Bulletins
Security Bulletin: CVE-2019-1552 vulnerability in OpenSSL affect IBM Workload Scheduler
19 Jun 202015:05
ibm
IBM Security Bulletins
Security Bulletin: IBM MQ for HP NonStop Server is affected by OpenSSL vulnerability CVE-2019-1552
23 Jan 202016:20
ibm
IBM Security Bulletins
Security Bulletin: IBM Aspera On Demand products are affected by OpenSSL Vulnerability (CVE-2019-1552)
20 May 202002:09
ibm
IBM Security Bulletins
Security Bulletin: OpenSSL vulnerability affects IBM Rational Team Concert
13 Feb 202014:42
ibm
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(503090);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/03/13");

  script_cve_id("CVE-2019-1552");
  script_xref(name:"ICSA", value:"22-349-21");

  script_name(english:"Siemens SCALANCE X-200RNA Switch Devices Improper Certificate Validation (CVE-2019-1552)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"OpenSSL has internal defaults for a directory tree where it can find a
configuration file as well as certificates used for verification in
TLS. This directory is most commonly referred to as OPENSSLDIR, and is
configurable with the --prefix / --openssldir configuration options.
For OpenSSL versions 1.1.0 and 1.1.1, the mingw configuration targets
assume that resulting programs and libraries are installed in a Unix-
like environment and the default prefix for program installation as
well as for OPENSSLDIR should be '/usr/local'. However, mingw programs
are Windows programs, and as such, find themselves looking at sub-
directories of 'C:/usr/local', which may be world writable, which
enables untrusted users to modify OpenSSL's default configuration,
insert CA certificates, modify (or even replace) existing engine
modules, etc. For OpenSSL 1.0.2, '/usr/local/ssl' is used as default
for OPENSSLDIR on all Unix and Windows targets, including Visual C
builds. However, some build instructions for the diverse Windows
targets on 1.0.2 encourage you to specify your own --prefix. OpenSSL
versions 1.1.1, 1.1.0 and 1.0.2 are affected by this issue. Due to the
limited scope of affected deployments this has been assessed as low
severity and therefore we are not creating new releases at this time.
Fixed in OpenSSL 1.1.1d (Affected 1.1.1-1.1.1c). Fixed in OpenSSL
1.1.0l (Affected 1.1.0-1.1.0k). Fixed in OpenSSL 1.0.2t (Affected
1.0.2-1.0.2s).

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/pdf/ssa-412672.pdf");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109814809/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-22-349-21");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-1552");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(295);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/12/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/03/13");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:scalance_x204rna_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2MB2']},
    "cpe:/o:siemens:scalance_x204rna_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BA00-2KB2']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28hsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-2NA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3LA3']},
    "cpe:/o:siemens:scalance_x204rna_eec_%28prp%2fhsr%29_firmware:3.2.7" :
        {"versionEndExcluding" : "3.2.7", "family" : "SCALANCEX200", "orderNumbers" : ['6GK5204-0BS00-3PA3']}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

13 Mar 2025 00:00Current
6.1Medium risk
Vulners AI Score6.1
CVSS 21.9
CVSS 33.3
EPSS0.00678
9