Lucene search
+L

1342 matches found

CVE
CVE
added 2022/07/13 9:11 p.m.80 views

CVE-2022-34765

CVE-2022-34765 is a CWE-73 vulnerability (External Control of File Name or Path) affecting Schneider Electric X80 advanced RTU Communication Module BMENOR2200H (V2.01 and later) and OPC UA Modicon Communication Module BMENUA0100 (V1.10 and prior). The issue arises when user-controlled data can in...

5.5CVSS5.2AI score0.00551EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/07/13 9:11 p.m.42 views

CVE-2022-34764

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prio...

5.9CVSS7.6AI score0.00671EPSS
SaveExploits0References1
CVE
CVE
added 2022/07/13 9:11 p.m.84 views

CVE-2022-34764

CVE-2022-34764 describes a CWE-119 vulnerability (improper restriction of operations within the bounds of a memory buffer) that could cause a denial of service when parsing URLs. Affected Schneider Electric devices include the X80 advanced RTU Communication Module BMENOR2200H (V1.0) and the OPC U...

7.5CVSS7.4AI score0.00671EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/07/13 9:11 p.m.85 views

CVE-2022-34763

The CVE-2022-34763 entry describes a CWE-345 vulnerability (Insufficient Verification of Data Authenticity) that could allow loading of unauthorized firmware images due to improper verification of the firmware signature. Affected products are Schneider Electric X80 advanced RTU Communication Modu...

7.5CVSS7.4AI score0.00279EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/07/13 9:11 p.m.42 views

CVE-2022-34763

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon...

5.9CVSS7.6AI score0.00279EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/07/13 9:10 p.m.36 views

CVE-2022-34762

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 an...

5.9CVSS7.6AI score0.00696EPSS
SaveExploits0References1
CVE
CVE
added 2022/07/13 9:10 p.m.93 views

CVE-2022-34762

The CVE-2022-34762 entry describes a path traversal (CWE-22) affecting Schneider Electric devices: the X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later) and the OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior). The vulnerability could allow loading of unautho...

7.5CVSS7.4AI score0.00696EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/07/13 9:10 p.m.42 views

CVE-2022-34761

A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prior...

7.5CVSS7.6AI score0.00868EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/07/13 9:10 p.m.56 views

CVE-2022-34760

A CWE-835: Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module...

7.5CVSS7.6AI score0.00762EPSS
SaveExploits0References1
CVE
CVE
added 2022/07/13 9:10 p.m.91 views

CVE-2022-34760

The CVE-2022-34760 issue is a CWE-835 Infinite Loop affecting Schneider Electric devices: X80 advanced RTU Communication Module BMENOR2200H (V1.0) and OPC UA Modicon Communication Module BMENUA0100 (V1.10 and earlier). The vulnerability arises from improper handling of cookies, potentially causin...

7.5CVSS7.3AI score0.00762EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/07/13 9:10 p.m.36 views

CVE-2022-34759

A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prior...

7.5CVSS7.6AI score0.00762EPSS
SaveExploits0References1
CVE
CVE
added 2022/07/13 9:10 p.m.72 views

CVE-2022-34759

CVE-2022-34759 describes a CWE-787Out-of-bounds Write vulnerability that could cause a denial of service to the webserver due to improper parsing of HTTP headers. Affected Schneider Electric devices include the X80 advanced RTU Communication Module BMENOR2200H (V1.0) and the OPC UA Modicon Commun...

7.5CVSS7.3AI score0.00762EPSS
SaveExploits0References1Affected Software1
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.13 views

多款Schneider Electric产品安全漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

5.5CVSS5.8AI score0.00551EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.14 views

多款Schneider Electric产品缓冲区错误漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.6AI score0.00762EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.9 views

多款Schneider Electric产品数据伪造问题漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.4AI score0.00279EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.12 views

多款Schneider Electric产品路径遍历漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.4AI score0.00696EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2022/07/13 12:00 a.m.14 views

多款Schneider Electric产品缓冲区错误漏洞

The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...

7.5CVSS7.6AI score0.00671EPSS
SaveExploits0References2
NVD
NVD
added 2022/07/11 11:15 a.m.29 views

CVE-2022-1794

The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...

5.5CVSS0.00211EPSS
SaveExploits0References1
Prion
Prion
added 2022/07/11 11:15 a.m.25 views

Design/Logic Flaw

The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...

4.7CVSS5.4AI score0.00211EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/07/11 10:40 a.m.39 views

CVE-2022-1794 Plaintext Storage of a password in CODESYS V3 OPC DA Server

The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...

5.5CVSS5.7AI score0.00211EPSS
SaveExploits0References1
Rows per page