1314 matches found
CVE-2022-34763
The CVE-2022-34763 entry describes a CWE-345 vulnerability (Insufficient Verification of Data Authenticity) that could allow loading of unauthorized firmware images due to improper verification of the firmware signature. Affected products are Schneider Electric X80 advanced RTU Communication Modu...
CVE-2022-34763
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon...
CVE-2022-34762
The CVE-2022-34762 entry describes a path traversal (CWE-22) affecting Schneider Electric devices: the X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later) and the OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior). The vulnerability could allow loading of unautho...
CVE-2022-34762
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 an...
CVE-2022-34761
A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V2.01 and later, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prior...
CVE-2022-34760
The CVE-2022-34760 issue is a CWE-835 Infinite Loop affecting Schneider Electric devices: X80 advanced RTU Communication Module BMENOR2200H (V1.0) and OPC UA Modicon Communication Module BMENUA0100 (V1.10 and earlier). The vulnerability arises from improper handling of cookies, potentially causin...
CVE-2022-34760
A CWE-835: Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module...
CVE-2022-34759
A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module BMENOR2200H V1.0, OPC UA Modicon Communication Module BMENUA0100 V1.10 and prior...
CVE-2022-34759
CVE-2022-34759 describes a CWE-787Out-of-bounds Write vulnerability that could cause a denial of service to the webserver due to improper parsing of HTTP headers. Affected Schneider Electric devices include the X80 advanced RTU Communication Module BMENOR2200H (V1.0) and the OPC UA Modicon Commun...
多款Schneider Electric产品数据伪造问题漏洞
The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...
多款Schneider Electric产品安全漏洞
The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...
多款Schneider Electric产品缓冲区错误漏洞
The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...
多款Schneider Electric产品路径遍历漏洞
The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...
多款Schneider Electric产品缓冲区错误漏洞
The Schneider Electric OPC UA Modicon Communication Module and the Schneider Electric X80 advanced RTU Communication Module are both products of the French company Schneider Electric. The Schneider Electric OPC UA Modicon Communication Module is an Ethernet communication module with an embedded O...
CVE-2022-1794
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...
Design/Logic Flaw
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...
CVE-2022-1794
CVE-2022-1794 affects the CODESYS OPC DA Server prior to v3.5.18.20, where PLC passwords are stored in plaintext in the configuration file and are visible to all authorized Windows users on the system. The vulnerability exposes credentials via local access to the host, as indicated by the CVSS ve...
CVE-2022-1794 Plaintext Storage of a password in CODESYS V3 OPC DA Server
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...
3S-Smart Software Solutions CODESYS 安全漏洞
CODESYS is a controller development system from 3S-Smart Software Solutions, Germany. A security vulnerability exists in 3S-Smart Software Solutions CODESYS OPC DA Server versions prior to V3.5.18.20, which stems from the PLC storing passwords as plain text in its configuration file, which is...
CVE-2022-1794
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...