Lucene search

K
nessusThis script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_SCHNEIDER_CVE-2022-34763.NASL
HistoryJul 27, 2022 - 12:00 a.m.

Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2022-34763)

2022-07-2700:00:00
This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
24

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

0.001 Low

EPSS

Percentile

31.9%

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)

  • A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products:
    X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) (CVE-2022-34763)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(500689);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/10/17");

  script_cve_id("CVE-2022-34763");

  script_name(english:"Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2022-34763)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized
firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU
Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)

  - A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of
    unauthorized firmware images due to improper verification of the firmware signature. Affected Products:
    X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module
    (BMENUA0100) (V1.10 and prior) (CVE-2022-34763)

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?16fcc8a3");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:C/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-34763");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(345);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/07/13");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/07/13");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/07/27");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmenor2200h_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:modicon_m580_bmenor2200h_firmware" :
        {"versionEndIncluding" : "2.01", "versionStartIncluding" : "2.01", "family" : "ModiconM340M580CP"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
schneider-electricmodicon_m580_bmenor2200h_firmwarecpe:/o:schneider-electric:modicon_m580_bmenor2200h_firmware

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

0.001 Low

EPSS

Percentile

31.9%

Related for TENABLE_OT_SCHNEIDER_CVE-2022-34763.NASL