Lucene search
+L

1341 matches found

Tenable Nessus
Tenable Nessus
added 2015/06/18 12:00 a.m.38 views

Schneider Electric InduSoft Web Studio < 7.1.3.4 Multiple Information Disclosures (SEVD-2015-054-01)

Binary data scadaindusoftwebstudioSEVD2015-054-01.nbin...

5CVSS6.8AI score0.02383EPSS
SaveExploits0References6
CNVD
CNVD
added 2015/05/26 12:00 a.m.9 views

Schneider Electric OPC Factory Server DLL Load Arbitrary Code Execution Vulnerability

Schneider Electric OPC Factory Server OFS is a set of data communication editing software. The software supports access to important information, open page design, transparent architecture and interoperability to enable good processes and communication. A security vulnerability exists in the...

7.3CVSS7AI score0.00456EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2015/05/01 12:00 a.m.32 views

Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX Object Multiple Buffer Overflows DoS

Binary data scadaopcfactoryserveractivex.nbin...

7.8CVSS7.3AI score0.02471EPSS
SaveExploits0References3
OpenVAS
OpenVAS
added 2015/04/11 12:00 a.m.41 views

Inductive Automation Ignition < 7.7.4 Multiple Vulnerabilities

Inductive Automation Ignition is prone to multiple vulnerabilities. SPDX-FileCopyrightText: 2015 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...

6.4CVSS9.3AI score0.0225EPSS
SaveExploits0References7
Tenable Nessus
Tenable Nessus
added 2015/04/09 12:00 a.m.28 views

SCADA Engine BACnet OPC Server < 2.1.371.24 Multiple Vulnerabilities

Binary data scadabacnetopcserver2137124.nbin...

9CVSS6.8AI score0.04564EPSS
SaveExploits0References4
NVD
NVD
added 2015/04/03 10:59 a.m.23 views

CVE-2015-0992

Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...

2.1CVSS5.7AI score0.00334EPSS
SaveExploits0References1
Prion
Prion
added 2015/04/03 10:59 a.m.22 views

Design/Logic Flaw

Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...

2.1CVSS6.2AI score0.00334EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/04/03 10:00 a.m.117 views

CVE-2015-0992

CVE-2015-0992 affects Inductive Automation Ignition 7.7.2, where OPC Server credentials are stored in plaintext in the settings file, enabling local users to obtain sensitive information via unspecified vectors. The connected documents corroborate plaintext storage of credentials as the root caus...

2.1CVSS5.8AI score0.00334EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2015/03/29 10:59 a.m.28 views

CVE-2015-0999

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...

2.1CVSS5.7AI score0.00372EPSS
SaveExploits0References3
Prion
Prion
added 2015/03/29 10:59 a.m.20 views

Design/Logic Flaw

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...

2.1CVSS6.2AI score0.00372EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2015/03/29 10:00 a.m.30 views

CVE-2015-0999

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...

5.6AI score0.00372EPSS
SaveExploits0References3
Kaspersky
Kaspersky
added 2015/03/16 12:00 a.m.56 views

KLA10502 Multiple vulnerabilities in BACnet OPC Server

Multiple critical vulnerabilities have been found in BACnet OPC Server. Malicious users can exploit these vulnerabilities to execute arbitrary files and read&write local database. Below is a complete list of vulnerabilities 1. An unknwon vulnerabilities can be exploited remotely via unknown vecto...

9CVSS7.9AI score0.04564EPSS
SaveExploits0References2
NVD
NVD
added 2015/03/14 1:59 a.m.20 views

CVE-2015-0981

The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...

7.5CVSS7AI score0.02575EPSS
SaveExploits0References1
NVD
NVD
added 2015/03/14 1:59 a.m.41 views

CVE-2015-0980

Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...

9CVSS7.6AI score0.03616EPSS
SaveExploits0References1
NVD
NVD
added 2015/03/14 1:59 a.m.35 views

CVE-2015-0979

Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...

9CVSS7.9AI score0.04564EPSS
SaveExploits0References1
Prion
Prion
added 2015/03/14 1:59 a.m.25 views

Format string

Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...

9CVSS8.2AI score0.03616EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2015/03/14 1:59 a.m.25 views

Heap overflow

Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...

9CVSS8.6AI score0.04564EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/03/14 1:00 a.m.111 views

CVE-2015-0979

Summary (CVE-2015-0979) : A heap-based buffer overflow in the SOAP web interface of the SCADA Engine BACnet OPC Server prior to version 2.1.371.24 allows remote arbitrary code execution via a crafted packet. The affected component is the Windows Service SOAP interface; exploitation is remote and ...

9CVSS8.2AI score0.04564EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/03/14 1:00 a.m.63 views

CVE-2015-0980

SCADA Engine BACnet OPC Server (BACnet OPC Server) before version 2.1.371.24 is affected by CVE-2015-0980 via a format-string vulnerability in the SOAP web interface (BACnOPCServer.exe). Exploitation could allow remote attackers to execute arbitrary code. The ICS-CERT advisory notes a fixed versi...

9CVSS7.8AI score0.03616EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2015/03/14 1:00 a.m.49 views

CVE-2015-0981

The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...

7AI score0.02575EPSS
SaveExploits0References1
Rows per page
Query Builder