1341 matches found
Schneider Electric InduSoft Web Studio < 7.1.3.4 Multiple Information Disclosures (SEVD-2015-054-01)
Binary data scadaindusoftwebstudioSEVD2015-054-01.nbin...
Schneider Electric OPC Factory Server DLL Load Arbitrary Code Execution Vulnerability
Schneider Electric OPC Factory Server OFS is a set of data communication editing software. The software supports access to important information, open page design, transparent architecture and interoperability to enable good processes and communication. A security vulnerability exists in the...
Schneider Electric OPC Factory Server (OFS) < 3.5 SP1 ActiveX Object Multiple Buffer Overflows DoS
Binary data scadaopcfactoryserveractivex.nbin...
Inductive Automation Ignition < 7.7.4 Multiple Vulnerabilities
Inductive Automation Ignition is prone to multiple vulnerabilities. SPDX-FileCopyrightText: 2015 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
SCADA Engine BACnet OPC Server < 2.1.371.24 Multiple Vulnerabilities
Binary data scadabacnetopcserver2137124.nbin...
CVE-2015-0992
Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...
Design/Logic Flaw
Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...
CVE-2015-0992
CVE-2015-0992 affects Inductive Automation Ignition 7.7.2, where OPC Server credentials are stored in plaintext in the settings file, enabling local users to obtain sensitive information via unspecified vectors. The connected documents corroborate plaintext storage of credentials as the root caus...
CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
Design/Logic Flaw
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
KLA10502 Multiple vulnerabilities in BACnet OPC Server
Multiple critical vulnerabilities have been found in BACnet OPC Server. Malicious users can exploit these vulnerabilities to execute arbitrary files and read&write local database. Below is a complete list of vulnerabilities 1. An unknwon vulnerabilities can be exploited remotely via unknown vecto...
CVE-2015-0981
The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...
CVE-2015-0980
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...
CVE-2015-0979
Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...
Format string
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...
Heap overflow
Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...
CVE-2015-0979
Summary (CVE-2015-0979) : A heap-based buffer overflow in the SOAP web interface of the SCADA Engine BACnet OPC Server prior to version 2.1.371.24 allows remote arbitrary code execution via a crafted packet. The affected component is the Windows Service SOAP interface; exploitation is remote and ...
CVE-2015-0980
SCADA Engine BACnet OPC Server (BACnet OPC Server) before version 2.1.371.24 is affected by CVE-2015-0980 via a format-string vulnerability in the SOAP web interface (BACnOPCServer.exe). Exploitation could allow remote attackers to execute arbitrary code. The ICS-CERT advisory notes a fixed versi...