1316 matches found
CVE-2015-0992
Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...
Design/Logic Flaw
Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...
CVE-2015-0992
CVE-2015-0992 affects Inductive Automation Ignition 7.7.2, where OPC Server credentials are stored in plaintext in the settings file, enabling local users to obtain sensitive information via unspecified vectors. The connected documents corroborate plaintext storage of credentials as the root caus...
CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
Design/Logic Flaw
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...
KLA10502 Multiple vulnerabilities in BACnet OPC Server
Multiple critical vulnerabilities have been found in BACnet OPC Server. Malicious users can exploit these vulnerabilities to execute arbitrary files and read&write local database. Below is a complete list of vulnerabilities 1. An unknwon vulnerabilities can be exploited remotely via unknown vecto...
CVE-2015-0981
The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...
CVE-2015-0980
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...
CVE-2015-0979
Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...
Format string
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...
Heap overflow
Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...
CVE-2015-0981
SCADA Engine BACnet OPC Server prior to version 2.1.371.24 is affected by three vulnerabilities tied to the SOAP web interface: (1) CVE-2015-0981 Authentication bypass allowing remote read/write of database fields, (2) CWE-122 Heap-based Buffer Overflow, and (3) CWE-20 Improper Input Validation. ...
CVE-2015-0980
SCADA Engine BACnet OPC Server (BACnet OPC Server) before version 2.1.371.24 is affected by CVE-2015-0980 via a format-string vulnerability in the SOAP web interface (BACnOPCServer.exe). Exploitation could allow remote attackers to execute arbitrary code. The ICS-CERT advisory notes a fixed versi...
CVE-2015-0979
Summary (CVE-2015-0979) : A heap-based buffer overflow in the SOAP web interface of the SCADA Engine BACnet OPC Server prior to version 2.1.371.24 allows remote arbitrary code execution via a crafted packet. The affected component is the Windows Service SOAP interface; exploitation is remote and ...
CVE-2015-0981
The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...
Schneider Electric OFS Server Vulnerability (Update A)
OVERVIEW --------- Begin Update A Part 1 of 4 -------- This updated advisory is a follow-up to the original advisory titled ICSA-15-141-01 Schneider Electric OFS Server Vulnerability that was published May 21, 2015, on the NCCIC/ICS-CERT web site. Ivan Sanchez from Nullcode Team has identified tw...
Rockwell Automation RSLinx Classic Vulnerability
OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on April 21, 2015, and is being released to the NCCIC/ICS-CERT web site. Ivan Sanchez of WiseSecurity Team has identified a stack-based buffer overflow vulnerability in Rockwell Automation’s OPCTest.exe, which is a...
BACnet-OPC-Client-Buffer-Overflow
After communicating via several emails with the vendor, sharing details about the vulnerability, as well as proof-of-concept code I also offered to send the exploit code for them to test themselves, it was clear that they weren't very interested in fixing the vulnerability. import sys import stru...
Schneider Electric OFS Buffer Overflow Vulnerability
OVERVIEW Schneider Electric has reported to NCCIC/ICS-CERT a Stack Buffer Overflow vulnerability supplied with the Schneider Electric OPC Factory Server OSF. Independent researcher known as 0x7A240E67 submitted the vulnerability to ZDI, who provided coordination with the vendor and ICS-CERT...