Lucene search
+L

1316 matches found

NVD
NVD
added 2015/04/03 10:59 a.m.18 views

CVE-2015-0992

Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...

2.1CVSS5.7AI score0.00334EPSS
SaveExploits0References1
Prion
Prion
added 2015/04/03 10:59 a.m.19 views

Design/Logic Flaw

Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors...

2.1CVSS6.2AI score0.00334EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/04/03 10:0 a.m.110 views

CVE-2015-0992

CVE-2015-0992 affects Inductive Automation Ignition 7.7.2, where OPC Server credentials are stored in plaintext in the settings file, enabling local users to obtain sensitive information via unspecified vectors. The connected documents corroborate plaintext storage of credentials as the root caus...

2.1CVSS5.8AI score0.00334EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2015/03/29 10:59 a.m.23 views

CVE-2015-0999

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...

2.1CVSS5.7AI score0.00372EPSS
SaveExploits0References3
Prion
Prion
added 2015/03/29 10:59 a.m.16 views

Design/Logic Flaw

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...

2.1CVSS6.2AI score0.00372EPSS
SaveExploits0References3Affected Software2
Cvelist
Cvelist
added 2015/03/29 10:0 a.m.23 views

CVE-2015-0999

Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file...

5.6AI score0.00372EPSS
SaveExploits0References3
Kaspersky
Kaspersky
added 2015/03/16 12:0 a.m.52 views

KLA10502 Multiple vulnerabilities in BACnet OPC Server

Multiple critical vulnerabilities have been found in BACnet OPC Server. Malicious users can exploit these vulnerabilities to execute arbitrary files and read&write local database. Below is a complete list of vulnerabilities 1. An unknwon vulnerabilities can be exploited remotely via unknown vecto...

9CVSS7.9AI score0.04564EPSS
SaveExploits0References2
NVD
NVD
added 2015/03/14 1:59 a.m.16 views

CVE-2015-0981

The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...

7.5CVSS7AI score0.02575EPSS
SaveExploits0References1
NVD
NVD
added 2015/03/14 1:59 a.m.35 views

CVE-2015-0980

Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...

9CVSS7.6AI score0.03616EPSS
SaveExploits0References1
NVD
NVD
added 2015/03/14 1:59 a.m.29 views

CVE-2015-0979

Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...

9CVSS7.9AI score0.04564EPSS
SaveExploits0References1
Prion
Prion
added 2015/03/14 1:59 a.m.19 views

Format string

Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request...

9CVSS8.2AI score0.03616EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2015/03/14 1:59 a.m.18 views

Heap overflow

Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet...

9CVSS8.6AI score0.04564EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/03/14 1:0 a.m.58 views

CVE-2015-0981

SCADA Engine BACnet OPC Server prior to version 2.1.371.24 is affected by three vulnerabilities tied to the SOAP web interface: (1) CVE-2015-0981 Authentication bypass allowing remote read/write of database fields, (2) CWE-122 Heap-based Buffer Overflow, and (3) CWE-20 Improper Input Validation. ...

7.5CVSS7.2AI score0.02575EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/03/14 1:0 a.m.55 views

CVE-2015-0980

SCADA Engine BACnet OPC Server (BACnet OPC Server) before version 2.1.371.24 is affected by CVE-2015-0980 via a format-string vulnerability in the SOAP web interface (BACnOPCServer.exe). Exploitation could allow remote attackers to execute arbitrary code. The ICS-CERT advisory notes a fixed versi...

9CVSS7.8AI score0.03616EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2015/03/14 1:0 a.m.103 views

CVE-2015-0979

Summary (CVE-2015-0979) : A heap-based buffer overflow in the SOAP web interface of the SCADA Engine BACnet OPC Server prior to version 2.1.371.24 allows remote arbitrary code execution via a crafted packet. The affected component is the Windows Service SOAP interface; exploitation is remote and ...

9CVSS8.2AI score0.04564EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2015/03/14 1:0 a.m.37 views

CVE-2015-0981

The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors...

7AI score0.02575EPSS
SaveExploits0References1
ICS
ICS
added 2015/02/21 7:0 a.m.49 views

Schneider Electric OFS Server Vulnerability (Update A)

OVERVIEW --------- Begin Update A Part 1 of 4 -------- This updated advisory is a follow-up to the original advisory titled ICSA-15-141-01 Schneider Electric OFS Server Vulnerability that was published May 21, 2015, on the NCCIC/ICS-CERT web site. Ivan Sanchez from Nullcode Team has identified tw...

7.3CVSS7.6AI score0.00456EPSS
SaveExploits0References10
ICS
ICS
added 2015/01/22 7:0 a.m.60 views

Rockwell Automation RSLinx Classic Vulnerability

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on April 21, 2015, and is being released to the NCCIC/ICS-CERT web site. Ivan Sanchez of WiseSecurity Team has identified a stack-based buffer overflow vulnerability in Rockwell Automation’s OPCTest.exe, which is a...

6.9CVSS6.8AI score0.01573EPSS
SaveExploits0References10
exploitpack
exploitpack
added 2015/01/07 12:41 p.m.29 views

BACnet-OPC-Client-Buffer-Overflow

After communicating via several emails with the vendor, sharing details about the vulnerability, as well as proof-of-concept code I also offered to send the exploit code for them to test themselves, it was clear that they weren't very interested in fixing the vulnerability. import sys import stru...

0.6AI score
SaveExploits0
ICS
ICS
added 2014/11/30 7:0 a.m.40 views

Schneider Electric OFS Buffer Overflow Vulnerability

OVERVIEW Schneider Electric has reported to NCCIC/ICS-CERT a Stack Buffer Overflow vulnerability supplied with the Schneider Electric OPC Factory Server OSF. Independent researcher known as 0x7A240E67 submitted the vulnerability to ZDI, who provided coordination with the vendor and ICS-CERT...

6.9CVSS7.5AI score0.00467EPSS
SaveExploits0References10
Rows per page