Modbus Version Scanner

This module detects the Modbus service, tested on a SAIA PCD1.M2 system. Modbus is a clear text protocol used in common SCADA systems, developed originally as a serial-line RS232 async protocol, and later transformed to IP, which is called ModbusTCP. This module requires Metasploit:...

6.9AI score
SaveExploits0
Exploit DB
Exploit DB
•added 2012/04/24 12:0 a.m.•79 views

RuggedCom Devices - Backdoor Access

Title: Undocumented Backdoor Access to RuggedCom Devices Author: jc Organization: JC CREW Date: April 23, 2012 CVE: CVE-2012-1803 Background: RuggedCom is one of a handful of networking vendors who capitalize on the market for "Industrial Strength" and "Hardened" networking equipment. You'll find...

8.5CVSS5.2AI score0.49395EPSS
SaveExploits9
Metasploit
Metasploit
•added 2012/04/05 5:35 p.m.•48 views

Schneider Modicon Remote START/STOP Command

The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to perform administrative commands without authentication. This module allows a remote user to change the state of the PLC between STOP and RUN, allowing an attacker to end process control by the PLC. This module is...

0.7AI score
SaveExploits0
Metasploit
Metasploit
•added 2012/04/05 5:35 p.m.•46 views

Schneider Modicon Ladder Logic Upload/Download

The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to send and receive ladder logic. The protocol is unauthenticated, and allows a rogue host to retrieve the existing logic and to upload new logic. Two modes are supported: "SEND" and "RECV," which behave as one might...

7.2AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•3 views

Non Compliant Scada Modbus Read File Record Response

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Non Compliant Scada Modbus Write Coils And Rst Comm

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Non Compliant Scada Modbus Write Multiple Coils Query

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•3 views

Scada Modbus Write Request To PLC

There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...

6.9AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Non Compliant Scada Modbus Write Multiple Regs Query

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•2 views

Scada Modbus Force Listen Only Mode

There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...

6.9AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Non Compliant Scada Modbus Read Device ID Query

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Scada Modbus Read Request To PLC

There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...

6.9AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•3 views

Non Compliant Scada Modbus Read Coils And Regs Response

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•3 views

Scada Modbus Acknowledge Exception Code Delay

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•3 views

Non Compliant Scada Modbus Function Code Size

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Non Compliant Scada Modbus Read Write Reg Response

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Scada Modbus Slave Device Busy Exception Code Delay

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•3 views

Non Compliant Scada Modbus Read File Record Query

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•4 views

Scada Modbus Points List Scan

...

7AI score
SaveExploits0
Check Point Advisories
Check Point Advisories
•added 2012/03/19 12:0 a.m.•5 views

Non Compliant Scada Modbus Read Device ID Response

...

7AI score
SaveExploits0