1739 matches found

NVD
NVD
added 2015/02/01 3:59 p.m.32 views

CVE-2014-9200

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM...

7.5CVSS8.1AI score0.05567EPSS
SaveExploits0References5
Cvelist
Cvelist
added 2015/02/01 3:00 p.m.37 views

CVE-2014-9200 Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow

Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM...

7.5CVSS8.1AI score0.05567EPSS
SaveExploits0References3
CVE
CVE
added 2015/02/01 3:00 p.m.73 views

CVE-2014-9200

Schneider Electric CVE-2014-9200 is a stack-based buffer overflow in an unspecified DLL within DTMs used by Unity Pro, SoMachine, SoMove, SoMove Lite and related libraries (Modbus 2.2.6 and earlier, CANopen 1.0.2 and earlier, EtherNet/IP 1.0.0 and earlier, EM X80 Gateway DTM, Advantys DTMs, KINOS...

7.5CVSS8.2AI score0.05567EPSS
SaveExploits0References5Affected Software4
ICS
ICS
added 2014/12/28 7:00 a.m.104 views

Schneider Electric Serial Modbus Driver Buffer Overflow (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-14-086-01A Schneider Electric Serial Modbus Driver Buffer Overflow that was published March 27, 2014, on the NCCIC/ICS-CERT web site. Carsten Eiram of Risk-Based Security has identified a stack-based buffer overflo...

9.3CVSS7.4AI score0.22293EPSS
SaveExploits10References10
Tenable Nessus
Tenable Nessus
added 2014/10/22 12:00 a.m.21 views

MODBUS/TCP Device Identification Object Detection

Binary data 7148.pasl...

7.3AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:00 a.m.39 views

Tri-PLC Nano-10 r81 - Denial of Service

No description provided by source. Exploit Title: Tri-PLC Nano-10 DoS Date: 07/11/2013 Exploit Author: Sapling Vendor Homepage: www.tri-plc.com Version: Firmware Version r81 and prior CVE : CVE-2013-2784 ICSA: ICSA-13-189-02 / The vulnerability exists due to a flaw in the PLC's ability to handle ...

7.8CVSS6.5AI score0.04041EPSS
SaveExploits5
seebug.org
seebug.org
added 2014/07/01 12:00 a.m.37 views

Automated Solutions Modbus/TCP OPC Server Remote Heap Corruption PoC

No description provided by source. !/usr/bin/python asmb-heap.py Automated Solutions Modbus/TCP OPC Server Remote Heap Corruption PoC Jeremy Brown 0xjbrown41-gmail-com Jan 2011 A specially crafted length field in a MODBUS packet header can trigger heap corruption. 00408312 | 8B5424 3C MOV EDX,DWO...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:00 a.m.29 views

Galil-RIO Modbus - Denial of Service

No description provided by source. Exploit Title: Galil RIO-47100 Date: 05-01-2013 Exploit Author: Sapling Vendor Homepage: www.galilmc.com Version: Rio Firmware Prior to 1.1d CVE : CVE-2013-0699 ICSA: ICSA-13-116-01 / There are many different ways to crash this PLC but most of them are centraliz...

7.1CVSS6.5AI score0.02793EPSS
SaveExploits6
seebug.org
seebug.org
added 2014/07/01 12:00 a.m.52 views

IOServer "Root Directory" Trailing Backslash Multiple Vulnerabilities

No description provided by source. ===================================================================== BEGIN Foofus.net Security Advisory: foofus-20120817 BEGIN ===================================================================== Title: IOServer Root Directory Trailing Backslash Web Server Vul...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/04/15 12:00 a.m.39 views

IOServer越界读取漏洞

Bugtraq ID:66761 CVE ID:CVE-2014-0777 IOServer是运行在Windows上的工业控制软件,包含内置Web服务器以支持XML服务器功能。 OPC Drivers 1.0.20之前版本内的Modbus从站及分站驱动程序在实现上存在越界读漏洞,攻击者通过特制的数据包,利用此漏洞可造成拒绝服务。 0 ioserver ioserver = 1.0.20 目前厂商已经发布了升级补丁以修复漏洞,请下载使用: http://www.ioserver.com/...

7.8CVSS6.6AI score0.02403EPSS
SaveExploits1
NVD
NVD
added 2014/04/11 4:55 p.m.28 views

CVE-2014-0777

The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service out-of-bounds read and daemon crash via a crafted packet...

8.3CVSS6.5AI score0.02403EPSS
SaveExploits1References3
Prion
Prion
added 2014/04/11 4:55 p.m.22 views

Out-of-bounds

The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service out-of-bounds read and daemon crash via a crafted packet...

7.8CVSS7AI score0.02403EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2014/04/11 4:00 p.m.74 views

CVE-2014-0777

The CVE-2014-0777 issue affects IOServer’s OPC Server (Windows) in the Modbus slave/outstation driver present in OPC Drivers 1.0.20 and earlier. The root cause is an out-of-bounds read in the Modbus driver, which attackers can trigger with a crafted packet to cause denial of service (daemon crash...

8.3CVSS6.7AI score0.02403EPSS
SaveExploits1References3Affected Software2
Cvelist
Cvelist
added 2014/04/11 4:00 p.m.37 views

CVE-2014-0777 OServer Out of Bounds Read

The Modbus slave/outstation driver in the OPC Drivers 1.0.20 and earlier in IOServer OPC Server allows remote attackers to cause a denial of service out-of-bounds read and daemon crash via a crafted packet...

8.3CVSS6.5AI score0.02403EPSS
SaveExploits1References2
NVD
NVD
added 2014/04/01 6:17 a.m.20 views

CVE-2013-0662

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...

9.3CVSS7.5AI score0.22293EPSS
SaveExploits10References5
Prion
Prion
added 2014/04/01 6:17 a.m.15 views

Stack overflow

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...

9.3CVSS8.2AI score0.22293EPSS
SaveExploits10References5Affected Software12
seebug.org
seebug.org
added 2014/03/31 12:00 a.m.42 views

Schneider Electric产品基于栈的缓冲区溢出漏洞

Bugtraq ID:66500 CVE ID:CVE-2013-0662 施耐德电气为100多个国家的能源及基础设施、工业、数据中心及网络、楼宇和住宅市场提供整体解决方案。 Schneider Electric多个产品使用的Modbus Serial驱动监听TCP 27700端口,当处理连接时,Modbus应用头字段会最先读入缓冲区,当在头字段指定超大缓冲区大小时可触发基于栈的缓冲区溢出,成功利用漏洞可以以应用程序上下文执行任意代码。 0 Schneider Electric TwidoSuite Versions 2.31.04 Schneider Electric PowerSui...

9.3CVSS2.9AI score0.22293EPSS
SaveExploits10
Cvelist
Cvelist
added 2014/03/28 7:00 p.m.42 views

CVE-2013-0662

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header...

7.5AI score0.22293EPSS
SaveExploits10References5
CVE
CVE
added 2014/03/28 7:00 p.m.141 views

CVE-2013-0662

The CVE-2013-0662 vulnerability affects Schneider Electric’s Modbus Serial Driver (ModbusDrv.exe) used by multiple Schneider Electric products. A stack-based buffer overflow is triggered when a large value is specified in the Modbus Application Header, enabling remote code execution with the user...

9.3CVSS7.6AI score0.22293EPSS
SaveExploits10References5Affected Software13
ThreatPost
ThreatPost
added 2014/03/28 10:34 a.m.36 views

Patch Available for Schneider Electric Serial Modbus Driver

Schneider Electric, a leading provider of industrial control systems, recently patched a remotely exploitable vulnerability in a driver found in 11 of its products. The Industrial Control Systems Computer Emergency Response Team ICS-CERT released an advisory yesterday alerting users to the...

2.2AI score
SaveExploits0References4