CAS Modbus RTU Parser Buffer Overflow SEH (PoC)
Exploit for windows platform in category dos / poc Title : CAS Modbus RTU Parser Buffer Overflow SEH PoC Author : Senator of Pirates Founder : Marshal Webb Link Software : http://www.chipkin.com/technical-resources/cas-modbus-rtu-parser/ FaceBook : /SenatorofPiratesInfo Marshal's FaceBook :...
RuggedCom Devices - Backdoor Access
Title: Undocumented Backdoor Access to RuggedCom Devices Author: jc Organization: JC CREW Date: April 23, 2012 CVE: CVE-2012-1803 Background: RuggedCom is one of a handful of networking vendors who capitalize on the market for "Industrial Strength" and "Hardened" networking equipment. You'll find...
Schneider Modicon Ladder Logic Upload/Download
The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to send and receive ladder logic. The protocol is unauthenticated, and allows a rogue host to retrieve the existing logic and to upload new logic. Two modes are supported: "SEND" and "RECV," which behave as one might...
Schneider Modicon Remote START/STOP Command
The Schneider Modicon with Unity series of PLCs use Modbus function code 90 0x5a to perform administrative commands without authentication. This module allows a remote user to change the state of the PLC between STOP and RUN, allowing an attacker to end process control by the PLC. This module is...
Scada Modbus Read Request To PLC
There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...
Scada Modbus Points List Scan
...
Non Compliant Scada Modbus Comm Event Log Response
...
Non Compliant Scada Modbus Read Coils Inputs Query
...
Scada Modbus Report Slave ID
There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...
Non Compliant Scada Modbus Write Multiple Regs Response
...
Non Compliant Scada Modbus Function Code Size
...
Scada Modbus Slave Device Busy Exception Code Delay
...
Non Compliant Scada Modbus Read Device ID Query
...
Non Compliant Scada Modbus Read Write Reg Query
...
Scada Modbus Incorrect Packet Length (CVE-2013-0662)
...
Non Compliant Scada Modbus Write Coils And Rst Comm
...
Non Compliant Scada Modbus Return Diag Regs
...
Non Compliant Scada Modbus Write Multiple Coils Query
...
Non Compliant Scada Modbus Write Multiple Coils Response
...
Scada Modbus Clear Counters And Diagnostic Registers
There are cases in which certain traffic, although not intended for malicious use, is very unsafe, since it may transfer shellcode which is undetectable by IPS...