Lucene search
+L

1724 matches found

NVD
NVD
added 2009/01/06 5:30 p.m.23 views

CVE-2008-5848

The Advantech ADAM-6000 module has 00000000 as its default password, which makes it easier for remote attackers to obtain access through an HTTP session, and 1 monitor or 2 control the module's Modbus/TCP I/O activity...

10CVSS6.7AI score0.03325EPSS
SaveExploits0References3
CVE
CVE
added 2009/01/06 5:0 p.m.70 views

CVE-2008-5848

The CVE-2008-5848 entry concerns the Advantech ADAM-6000 module which ships with a default password of 00000000. This default credential enables remote attackers to gain access via an HTTP session and, from there, monitor or control the module’s Modbus/TCP I/O activity. The connected sources conf...

10CVSS6.9AI score0.03325EPSS
SaveExploits0References3Affected Software14
Cvelist
Cvelist
added 2009/01/06 5:0 p.m.33 views

CVE-2008-5848

The Advantech ADAM-6000 module has 00000000 as its default password, which makes it easier for remote attackers to obtain access through an HTTP session, and 1 monitor or 2 control the module's Modbus/TCP I/O activity...

6.7AI score0.03325EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
added 2009/01/06 12:0 a.m.14 views

PT-2009-1325 · Advantech · Adam-6000

Name of the Vulnerable Software and Affected Versions: Advantech ADAM-6000 module affected versions not specified Description: The issue allows remote attackers to easily obtain access to the module through an HTTP session, due to a default password of 00000000. This access enables attackers to 1...

10CVSS6.5AI score0.03325EPSS
SaveExploits0References4
CERT
CERT
added 2008/10/31 12:0 a.m.58 views

Automated Solutions Modbus TCP Slave ActiveX Control Vulnerability

Overview Automated Solutions Modbus TCP Slave ActiveX Control contains a vulnerability that may allow a remote attacker to execute arbitrary code or cause a denial-of-service. Description Automated Solutions Modbus TCP Slave ActiveX Control fails to properly process malformed "Modbus" requests to...

7.5CVSS7.6AI score0.04734EPSS
SaveExploits0References8
NVD
NVD
added 2007/09/19 6:17 p.m.15 views

CVE-2007-4827

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502...

7.5CVSS7.7AI score0.04734EPSS
SaveExploits0References9
Prion
Prion
added 2007/09/19 6:17 p.m.15 views

Heap overflow

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502...

7.5CVSS8.3AI score0.04734EPSS
SaveExploits0References9Affected Software1
Cvelist
Cvelist
added 2007/09/19 6:0 p.m.25 views

CVE-2007-4827

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502...

7.7AI score0.04734EPSS
SaveExploits0References9
CVE
CVE
added 2007/09/19 6:0 p.m.71 views

CVE-2007-4827

CVE-2007-4827 affects Automated Solutions Modbus Slave ActiveX Control (MiniHMI.exe) and its Modbus/TCP Diagnostic function. The vulnerability occurs when processing malformed Modbus requests to TCP port 502, causing heap corruption and potentially arbitrary code execution. The issue is remote an...

7.5CVSS7.7AI score0.04734EPSS
SaveExploits0References9Affected Software1
securityvulns
securityvulns
added 2007/09/19 12:0 a.m.398 views

TPTI-07-15: Automated Solutions Modbus TCP Slave ActiveX Control Heap Corruption Vulnerability

TPTI-07-15: Automated Solutions Modbus TCP Slave ActiveX Control Heap Corruption Vulnerability http://www.zerodayinitiative.com/advisories/TPTI-07-15.html September 17, 2007 -- CVE ID: CVE-2007-4827 -- Affected Vendor: Automated Solutions -- Affected Products: Modbus RTU/ASCII/TCP Slave ActiveX...

7.5CVSS1AI score0.04734EPSS
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2007/09/19 12:0 a.m.22 views

Automated Solutions Modbus Slave MiniHMI.exe ActiveX Modbus/TCP Diagnostic Function Arbitrary Code Execution

Binary data scadaasmbslvactivexheapcorruption.nbin...

7.5CVSS7.3AI score0.04734EPSS
SaveExploits0References4
securityvulns
securityvulns
added 2007/09/19 12:0 a.m.34 views

Automated Solutions Modbus TCP Slave ActiveX memory corruption

Memory corruption on TCP/502 request handling...

7.5CVSS1.5AI score0.04734EPSS
SaveExploits0References1
seebug.org
seebug.org
added 2007/03/21 12:0 a.m.70 views

Takebishi Electric DeviceXPlorer OPC服务器远程代码执行漏洞

OPC OLE for Process Control 是一款为保证工业软件和设备的互联性而制订的程序接口国际标准。 Takebishi Electric DeviceXPlorer OPC服务器存在设计错误,远程攻击者可以利用漏洞以应用程序进程权限执行任意指令。 通过OPCDA接口,可导致在OPC Server上访问任意内存,可导致执行任意指令。如下版本的DeviceXPlorer OPC Server受此漏洞影响: DeviceXPlorer MELSEC OPC Server DeviceXPlorer SYSMAC OPC Server DeviceXPlorer FA-M3 O...

7.1AI score
SaveExploits0
NVD
NVD
added 2007/03/19 10:19 p.m.31 views

CVE-2007-1319

Unspecified vulnerability in the IOPCServer::RemoveGroup function in the OPCDA interface in Takebishi Electric DeviceXPlorer OLE for Process Control OPC Server before 3.12 Build3 allows remote attackers to execute arbitrary code via unspecified vectors involving access to arbitrary memory. NOTE:...

10CVSS7.6AI score0.09055EPSS
SaveExploits0References16
Prion
Prion
added 2007/03/19 10:19 p.m.17 views

Code injection

Unspecified vulnerability in the IOPCServer::RemoveGroup function in the OPCDA interface in Takebishi Electric DeviceXPlorer OLE for Process Control OPC Server before 3.12 Build3 allows remote attackers to execute arbitrary code via unspecified vectors involving access to arbitrary memory. NOTE:...

10CVSS8.2AI score0.09055EPSS
SaveExploits0References16Affected Software1
CVE
CVE
added 2007/03/19 10:0 p.m.47 views

CVE-2007-1319

The CVE refers to an arbitrary code execution vulnerability in the Takebishi DeviceXPlorer OPC Server family (HIDIC, SYSMAC, MELSEC, FA-M3, MODBUS) via the OPC DA interface. The issue stems from the server implementation of the IOPCServer::RemoveGroup method, which can access arbitrary memory and...

10CVSS7.5AI score0.09055EPSS
SaveExploits0References16Affected Software1
Cvelist
Cvelist
added 2007/03/19 10:0 p.m.38 views

CVE-2007-1319

Unspecified vulnerability in the IOPCServer::RemoveGroup function in the OPCDA interface in Takebishi Electric DeviceXPlorer OLE for Process Control OPC Server before 3.12 Build3 allows remote attackers to execute arbitrary code via unspecified vectors involving access to arbitrary memory. NOTE:...

7.6AI score0.09055EPSS
SaveExploits0References16
Tenable Nessus
Tenable Nessus
added 2006/12/11 12:0 a.m.27 views

Modbus/TCP Discrete Input Access

Binary data scadamodbusdicheck.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
added 2006/12/11 12:0 a.m.20 views

Modicon Modbus/TCP Programming Function Code Access

Binary data scadamodbusmodiconprogram.nbin...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2006/12/11 12:0 a.m.24 views

Modicon PLC Modbus Slave Mode SNMP Request Modbus Mode Remote Disclosure

Binary data scadamodiconsnmpmodbustype.nbin...

7.3AI score
SaveExploits0
Rows per page
Query Builder