1724 matches found
Buffer overflow
Buffer overflow in the Advantech ADAM OLE for Process Control OPC Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors...
MODBUS Client 'Report Server Information' Request (SCADA) (deprecated)
Binary data 6261.prm...
MODBUS Client 'Force Listen Only Mode' Request (SCADA) (deprecated)
Binary data 6257.prm...
MODBUS Client 'Clear Counters and Diagnostic Registers' Request (SCADA) (deprecated)
Binary data 6259.prm...
MODBUS Client 'Restart Communications' Request (SCADA) (deprecated)
Binary data 6258.prm...
MODBUS Client 'Read Device Identification' Request (SCADA) (deprecated)
Binary data 6260.prm...
CVE-2011-4861
The modbus125handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502...
Code injection
The modbus125handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502...
CVE-2011-4861
The CVE-2011-4861 entry concerns Schneider Electric Quantum Ethernet Module (NOE 771 / Quantum 140NOE771*) that allows remote firmware updates via the MODBUS 125 function code sent to TCP port 502 through the modbus_125_handler. This is a software/firmware update mechanism vulnerability in the de...
CVE-2011-4861
The modbus125handler function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device aka the Quantum 140NOE771 module allows remote attackers to install arbitrary firmware updates via a MODBUS 125 function code to TCP port 502...
Multiple Vulnerabilities Haunt Long List of PLC Modules
A long list of industrial-control modules manufactured by Schneider Electric and used to control operations at various industrial facilities contain multiple weaknesses and vulnerabilities that could allow an attacker to modify the firmware, login remotely and run arbitrary code on the vulnerable...
Modbus Version Scanner
This module detects the Modbus service, tested on a SAIA PCD1.M2 system. Modbus is a clear text protocol used in common SCADA systems, developed originally as a serial-line RS232 async protocol, and later transformed to IP, which is called ModbusTCP. Module Options msf use...
Nmap NSE net: modbus-discover
Enumerates SCADA Modbus slave ids sids and collects their device information. Modbus is one of the popular SCADA protocols. This script does Modbus device information disclosure. It tries to find legal sids slave ids of Modbus devices and to get additional information about the vendor and firmwar...
Nmap NSE net: modbus-discover
This VT has been deprecated and is therefore no longer functional. SPDX-FileCopyrightText: 2011 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only ifdescription...
Automated Solutions Modbus/TCP OPC Server Detection
Binary data scadaappautomatedasmbtcpopcdetect.nbin...
Modbus/TCP Master OPC Server MODBUS Protocol Response Packet Remote Overflow
Binary data scadaasmbtcpopc302.nbin...
CVE-2010-4733
WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the IntelliCom NetBiter NB100 and NB200 platforms have a default username and password, which makes it easier for remote attackers to obtain superadmin access via the web interface, a...
Default credentials
WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the IntelliCom NetBiter NB100 and NB200 platforms have a default username and password, which makes it easier for remote attackers to obtain superadmin access via the web interface, a...
Design/Logic Flaw
cgi-bin/read.cgi in WebSCADA WS100 and WS200, Easy Connect EC150, Modbus RTU - TCP Gateway MB100, and Serial Ethernet Server SS100 on the IntelliCom NetBiter NB100 and NB200 platforms allows remote authenticated administrators to execute arbitrary code by using a config.html 2.conf action to...
CVE-2010-4733
CVE-2010-4733 and related entries describe default-credential and remote-authenticated risks affecting Intellicom NetBiter NetSCADA WebSCADA components (WS100/WS200, EC150, MB100, SS100 on NB100/NB200). The root issue cited is default usernames/passwords allowing superadmin access via the web int...