1927 matches found
CVE-2017-13764
In Wireshark 2.4.0, the Modbus dissector could crash with a NULL pointer dereference. This was addressed in epan/dissectors/packet-mbtcp.c by adding length validation...
CVE-2017-13764
In Wireshark 2.4.0, the Modbus dissector could crash with a NULL pointer dereference. This was addressed in epan/dissectors/packet-mbtcp.c by adding length validation...
CVE-2017-13764
CVE-2017-13764 affects Wireshark 2.4.0 with the Modbus (mbtcp) dissector. The issue is a NULL pointer dereference caused by insufficient length validation, leading to a crash. The fix was implemented in epan/dissectors/packet-mbtcp.c by adding length validation, mitigating the crash condition.
CVE-2017-13764: NULL Pointer Dereference
In Wireshark 2.4.0, the Modbus dissector could crash with a NULL pointer dereference. This was addressed in epan/dissectors/packet-mbtcp.c by adding length validation...
KLA11096 Denial of service vulnerability in Wireshark
An unspecified vulnerability was found in Modbus dissector in Wireshark. By exploiting this vulnerability malicious users can cause a denial of service. This vulnerability can be exploited remotely via a specially designed packet, which is injected onto the wire, or by convincing a user to read a...
Siemens SIPROTEC 4 and SIPROTEC Compact (Update C)
CVSS v3 8.6 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIPROTEC 4 and SIPROTEC Compact Vulnerabilities: Improper Input Validation, Missing Authorization, Improper Authentication UPDATE INFORMATION This updated advisory is a follow-up to the updated...
Design/Logic Flaw
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...
CVE-2017-7905
A Weak Cryptography for Passwords issue was discovered in General Electric GE Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Versio...
CVE-2017-7905
A Weak Cryptography for Passwords issue was discovered in General Electric GE Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Versio...
Authentication flaw
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6034
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6032
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...
Command injection
A Weak Cryptography for Passwords issue was discovered in General Electric GE Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Versio...
CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-6034 Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...
CVE-2017-7905
A Weak Cryptography for Passwords issue was discovered in General Electric GE Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Versio...
CVE-2017-6034
CVE-2017-6034 affects Schneider Electric Modicon Modbus Protocol. The vulnerability is an Authentication Bypass by Capture-Replay, enabling an attacker to replay sensitive Modbus commands (run/stop/upload/download) with cleartext traffic and network access. The issue is associated with the Modico...
CVE-2017-6032
CVE-2017-6032 concerns Schneider Electric Modicon Modbus Protocol: a session-related weakness in Modbus that may allow brute-force-style access. Affected component: Modbus protocol in Schneider Electric Modicon PLCs; impact described as potential exposure of control commands with low to moderate ...
CVE-2017-6032
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks...
CVE-2017-6034: Authentication Bypass by Capture-replay
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download...