Positive Technologies
Positive Technologies
added 2023/06/13 12:0 a.m.13 views

PT-2023-15291 · Bd · Alaris Infusion Central

Name of the Vulnerable Software and Affected Versions: Alaris Infusion Central software versions 1.1 to 1.3.2 Description: The issue concerns a recoverable password that may be present after the installation of the software. It is noted that no patient health data is stored in the database by...

7.3CVSS6.8AI score0.00162EPSS
SaveExploits0References4
OSV
OSV
added 2023/03/13 9:15 a.m.7 views

CVE-2023-0888

An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device...

7.2CVSS5.8AI score0.00604EPSS
SaveExploits0References2
Prion
Prion
added 2023/03/13 9:15 a.m.26 views

Design/Logic Flaw

An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device...

5.8CVSS6.9AI score0.00604EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2023/03/13 8:14 a.m.41 views

CVE-2023-0888 Authenticated eval injection in B. Braun Space Battery pack SP with Wi-Fi

An improper neutralization of directives in dynamically evaluated code vulnerability in the WiFi Battery embedded web server in versions L90/U70 and L92/U92 can be used to gain administrative access to the WiFi communication module. An authenticated user, having access to both the medical device...

4.9CVSS7.3AI score0.00604EPSS
SaveExploits0References2
CVE
CVE
added 2023/03/13 8:14 a.m.82 views

CVE-2023-0888

Summary of this CVE (CVE-2023-0888) : A vulnerability in the Wi‑Fi Battery embedded web server of the B. Braun Space Battery Pack SP with Wi‑Fi, affecting versions L90/U70 and L92/U92. It is an improper neutralization of directives in dynamically evaluated code (Eval Injection) that could allow a...

7.2CVSS6.1AI score0.00604EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
added 2023/03/13 12:0 a.m.8 views

B. Braun SpaceCom 代码注入漏洞

B. Braun SpaceCom is a miniature camera for medical applications from B. Braun. A security vulnerability exists in the B. Braun SpaceCom WiFi Battery embedded web server versions L90/U70 and L92/U92, which can be exploited by an attacker to gain administrative access to the WiFi communication...

7.2CVSS7.2AI score0.00604EPSS
SaveExploits0References3
CISA
CISA
added 2023/02/16 12:0 a.m.25 views

CISA Releases Fifteen Industrial Control Systems Advisories

CISA released fifteen 15 Industrial Control Systems ICS advisories on February 16, 2023. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. CISA encourages users and administrators to review the newly released ICS advisories f...

1.7AI score
SaveExploits0References15
ICS
ICS
added 2023/02/16 12:0 a.m.36 views

BD Alaris Infusion Central

1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low attack complexity Vendor: Becton, Dickinson and Company BD Equipment: Alaris Infusion Central --------- Begin Update A part 1 of 2 --------- Vulnerability: Storing Passwords in a Recoverable Format --------- End Update A part 1 of 2 --------- 2...

7.3CVSS7.1AI score0.00162EPSS
SaveExploits0References6
NVD
NVD
added 2022/12/05 10:15 p.m.21 views

CVE-2022-43557

The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 serial port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information ePHI, protected heal...

5.3CVSS0.00218EPSS
SaveExploits0References1
Prion
Prion
added 2022/12/05 10:15 p.m.16 views

Code injection

The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 serial port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information ePHI, protected heal...

3.7CVSS5AI score0.00218EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/12/05 12:0 a.m.40 views

CVE-2022-43557 BD BodyGuard™ Pumps – RS-232 Interface Vulnerability

The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 serial port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or disable the pump. No electronic protected health information ePHI, protected heal...

5.3CVSS5.2AI score0.00218EPSS
SaveExploits0References1
CVE
CVE
added 2022/12/05 12:0 a.m.66 views

CVE-2022-43557

The CVE-2022-43557 issue affects BD BodyGuard infusion pumps via the RS-232 serial port. Documents consistently state that threat actors with physical access and specialized equipment could configure or disable the pump by exploiting the alternate hardware interface. The vulnerability has a CVSSv...

5.3CVSS4.9AI score0.00218EPSS
SaveExploits0References1Affected Software1
The Hacker News
The Hacker News
added 2022/09/08 5:55 p.m.70 views

New Vulnerabilities Reported in Baxter's Internet-Connected Infusion Pumps

Multiple security vulnerabilities have been disclosed in Baxter's internet-connected infusion pumps used by healthcare professionals in clinical environments to dispense medication to patients. "Successful exploitation of these vulnerabilities could result in access to sensitive data and alterati...

0.1AI score0.00596EPSS
SaveExploits0
Rapid7 Blog
Rapid7 Blog
added 2022/09/08 4:30 p.m.76 views

Baxter SIGMA Spectrum Infusion Pumps: Multiple Vulnerabilities (FIXED)

Rapid7, Inc. Rapid7 discovered vulnerabilities in two TCP/IP-enabled medical devices produced by Baxter Healthcare. The affected products are: SIGMA Spectrum Infusion Pump Firmware Version 8.00.01 SIGMA Wi-Fi Battery Firmware Versions 16, 17, 20 D29 Rapid7 initially reported these issues to Baxte...

0.9AI score0.01071EPSS
SaveExploits3
CNNVD
CNNVD
added 2022/09/08 12:0 a.m.6 views

Baxter Spectrum 格式化字符串错误漏洞

Baxter Spectrum is an infusion pump from Baxter USA. A format string error vulnerability exists in the Baxter Sigma and Baxter Spectrum Infusion Pumps that stems from its susceptibility to a format string attack delivered via an application message resulting in an attacker being able to use it to...

6.5CVSS7.3AI score0.00576EPSS
SaveExploits0References4
ICS
ICS
added 2022/09/08 12:0 a.m.45 views

Baxter Sigma Spectrum Infusion Pump (Update A)

1. EXECUTIVE SUMMARY --------- Begin Update A part 1 of 3 --------- CVSS v3 7.5 --------- End Update A part 1 of 3 --------- ATTENTION: Exploitable remotely Vendor: Baxter Equipment: Sigma and Baxter Spectrum Infusion Pumps Vulnerabilities: Missing Encryption of Sensitive Data, Use of Externally...

8.1CVSS6.4AI score0.00596EPSS
SaveExploits0References5
HackRead
HackRead
added 2022/03/03 7:51 p.m.25 views

75% of Tested Smart Infusion Pumps Vulnerable to Hacking

By Deeba Ahmed As of 2020, about 80% of hospitals in the United States were using smart infusion pumps. Palo Alto… This is a post from HackRead.com Read the original post: 75% of Tested Smart Infusion Pumps Vulnerable to Hacking...

1.1AI score
SaveExploits0
The Hacker News
The Hacker News
added 2022/03/03 9:4 a.m.150 views

Report: Nearly 75% of Infusion Pumps Affected by Severe Vulnerabilities

An analysis of data crowdsourced from more than 200,000 network-connected infusion pumps used in hospitals and healthcare entities has revealed that 75% of those medical devices contain security weaknesses that could put them at risk of potential exploitation. "These shortcomings included exposur...

9.8CVSS8.4AI score0.7525EPSS
SaveExploits6
Cvelist
Cvelist
added 2022/01/21 6:17 p.m.38 views

CVE-2021-43355 Fresenius Kabi Agilia Connect Infusion System use of client side authentication

Fresenius Kabi Vigilant Software Suite Mastermed Dashboard version 2.0.1.3 allows user input to be validated on the client side without authentication by the server. The server should not rely on the correctness of the data because users might not support or block JavaScript or intentionally bypa...

7.3CVSS9.8AI score0.00978EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2022/01/21 6:17 p.m.25 views

CVE-2021-33848 Fresenius Kabi Agilia Connect Infusion System cross site scripting

Fresenius Kabi Vigilant Software Suite Mastermed Dashboard version 2.0.1.3 is vulnerable to reflected cross-site scripting attacks. An attacker could inject JavaScript in a GET parameter of HTTP requests and perform unauthorized actions such as stealing internal information and performing actions...

5.4CVSS6AI score0.00611EPSS
SaveExploits0References1