Breaking the Security Barrier of a Globally Deployed Infusion Pump
ARCHIVED STORY Overmedicated: Breaking the Security Barrier of a Globally Deployed Infusion Pump By Douglas McKee, Steve Povolny and Philippe Laulheret · August 24, 2021 Cyberattacks on medical centers are one of the most despicable forms of cyber threat there is. For instance, on October 28th,...
CVE-2020-23658
PHP-Fusion 9.03.60 is affected by Cross Site Scripting XSS via infusions/memberpollpanel/polladmin.php...
CVE-2020-12039
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...
CVE-2020-12040
Sigma Spectrum Infusion System v's6.x model 35700BAX and Baxter Spectrum Infusion System Versions 8.x model 35700BAX2 at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has...
CVE-2020-12040
Sigma Spectrum Infusion System v's6.x model 35700BAX and Baxter Spectrum Infusion System Versions 8.x model 35700BAX2 at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has...
Hardcoded credentials
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...
CVE-2020-12040
CVE-2020-12040 affects Sigma Spectrum Infusion System v6.x (model 35700BAX) and Baxter Spectrum Infusion System v8.x (model 35700BAX2); root cause is unauthenticated clear-text transmission of system status and operational data at the application layer, enabling eavesdropping or MiTM if network c...
CVE-2020-12039
CVE-2020-12039 affects Baxter Sigma Spectrum Infusion System v6.x (35700BAX) and v8.x (35700BAX2); hard-coded passwords entered via keypad grant access to biomedical menus, including device settings, calibration values, and WBM network configuration. This is a local/physical-access issue with pub...
CVE-2020-12039
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...
Unspecified Vulnerability in Baxter Sigma Spectrum Infusion System and Baxter Spectrum Infusion System
The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A security vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x model 35700BAX2,...
Unspecified Vulnerability in Baxter Spectrum WBM
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability. An attacker could exploit this vulnerability to...
Baxter Sigma Spectrum Infusion System and Spectrum Infusion System Trust Management Issues Vulnerabilities
The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A trust management issue vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x mod...
Unspecified Vulnerability in Baxter Spectrum WBM (CNVD-2021-21076)
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. A security vulnerability exists in the Baxter Spectrum WBM that can be exploited by an attacker to gain access to F...
Baxter Spectrum WBM Trust Management Issues Vulnerability (CNVD-2021-21077)
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum is vulnerable to a trust management issue that could be exploited by an attacke...
Baxter Spectrum WBM Trust Management Issues Vulnerability
The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability that can be exploited by an attacker to run Telnet...
Baxter Sigma Spectrum Infusion Pumps (Update B)
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Baxter Equipment: Sigma Spectrum Infusion Pumps Vulnerabilities: Use of Hard-coded Password, Cleartext Transmission of Sensitive Data, Incorrect Permission Assignment for Critical Resource, Operation on...
Interpeak IPnet TCP/IP Stack (Update E)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available Vendor : ENEA, Green Hills Software, ITRON, IP Infusion, Wind River Equipment : OSE by ENEA, INTEGRITY RTOS by Green Hills Software, ITRON, ZebOS by IP Infusion, and...
BD Alaris Gateway Workstation Arbitrary File Upload Vulnerability
BD Alaris Gateway Workstation is an intelligent infusion system, BD Alaris GS is a medical syringe pump, and BD Alaris GH is a medical syringe pump. The BD Alaris Gateway Workstation has arbitrary file upload vulnerabilities. An attacker could use these vulnerabilities to upload arbitrary files t...
Vulnerable infusion pumps can be remotely accessed to change dosages
By Waqas Critical Bug in Medical Infusion Pumps lets Attacker Remotely install Unauthorized Firmware to Change Medication Dosages. Researchers at CyberMDX, a healthcare security firm, have identified two different vulnerabilities in Becton Dickinson Alaris Gateway Workstations AGW used by hospita...
Max-Severity Bug in Infusion Pump Gateway Puts Lives at Risk
Researchers have disclosed two separate vulnerabilities within the Becton Dickinson Alaris Gateway Workstation for medical infusion pumps in hospitals, one carrying a critical rating of 10 out of 10 on the CVSS v.3 severity scale. Alaris Gateway Workstations power, monitor and control infusion...