Breaking the Security Barrier of a Globally Deployed Infusion Pump

ARCHIVED STORY Overmedicated: Breaking the Security Barrier of a Globally Deployed Infusion Pump By Douglas McKee, Steve Povolny and Philippe Laulheret · August 24, 2021 Cyberattacks on medical centers are one of the most despicable forms of cyber threat there is. For instance, on October 28th,...

0.3AI score
SaveExploits0
NVD
NVD
added 2020/08/26 6:15 p.m.17 views

CVE-2020-23658

PHP-Fusion 9.03.60 is affected by Cross Site Scripting XSS via infusions/memberpollpanel/polladmin.php...

5.4CVSS5.4AI score0.00486EPSS
SaveExploits1References1
NVD
NVD
added 2020/06/29 2:15 p.m.39 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

2.4CVSS0.00333EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/29 2:15 p.m.39 views

CVE-2020-12040

Sigma Spectrum Infusion System v's6.x model 35700BAX and Baxter Spectrum Infusion System Versions 8.x model 35700BAX2 at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has...

9.8CVSS0.00948EPSS
SaveExploits1References1
OSV
OSV
added 2020/06/29 2:15 p.m.10 views

CVE-2020-12040

Sigma Spectrum Infusion System v's6.x model 35700BAX and Baxter Spectrum Infusion System Versions 8.x model 35700BAX2 at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has...

9.8CVSS7AI score0.00948EPSS
SaveExploits1References1
Prion
Prion
added 2020/06/29 2:15 p.m.27 views

Hardcoded credentials

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

2.1CVSS5.1AI score0.00333EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/06/29 1:45 p.m.89 views

CVE-2020-12040

CVE-2020-12040 affects Sigma Spectrum Infusion System v6.x (model 35700BAX) and Baxter Spectrum Infusion System v8.x (model 35700BAX2); root cause is unauthenticated clear-text transmission of system status and operational data at the application layer, enabling eavesdropping or MiTM if network c...

9.8CVSS9.3AI score0.00948EPSS
SaveExploits1References1Affected Software1
CVE
CVE
added 2020/06/29 1:45 p.m.71 views

CVE-2020-12039

CVE-2020-12039 affects Baxter Sigma Spectrum Infusion System v6.x (35700BAX) and v8.x (35700BAX2); hard-coded passwords entered via keypad grant access to biomedical menus, including device settings, calibration values, and WBM network configuration. This is a local/physical-access issue with pub...

2.4CVSS4.1AI score0.00333EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:45 p.m.33 views

CVE-2020-12039

Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration value...

3.8AI score0.00333EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.36 views

Unspecified Vulnerability in Baxter Sigma Spectrum Infusion System and Baxter Spectrum Infusion System

The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A security vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x model 35700BAX2,...

9.8CVSS6.6AI score0.00948EPSS
SaveExploits1References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.22 views

Unspecified Vulnerability in Baxter Spectrum WBM

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability. An attacker could exploit this vulnerability to...

9.4CVSS6.8AI score0.01406EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.17 views

Baxter Sigma Spectrum Infusion System and Spectrum Infusion System Trust Management Issues Vulnerabilities

The Baxter Sigma Spectrum Infusion System and the Baxter Spectrum Infusion System are both infusion pumps from Baxter, Inc. A trust management issue vulnerability exists in the Baxter Sigma Spectrum Infusion System version 6.x model 35700BAX and the Baxter Spectrum Infusion System version 8.x mod...

2.4CVSS6.8AI score0.00333EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.23 views

Unspecified Vulnerability in Baxter Spectrum WBM (CNVD-2021-21076)

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. A security vulnerability exists in the Baxter Spectrum WBM that can be exploited by an attacker to gain access to F...

9.8CVSS7.1AI score0.02098EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.23 views

Baxter Spectrum WBM Trust Management Issues Vulnerability (CNVD-2021-21077)

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum is vulnerable to a trust management issue that could be exploited by an attacke...

9.8CVSS6.7AI score0.01676EPSS
SaveExploits0References1
CNVD
CNVD
added 2020/06/19 12:00 a.m.16 views

Baxter Spectrum WBM Trust Management Issues Vulnerability

The Baxter WBM and Baxter Spectrum are both products of Baxter, Inc.The Baxter WBM is a wireless battery module for use with Baxter products.The Baxter Spectrum is an infusion pump. The WBM used in the Baxter Spectrum has a security vulnerability that can be exploited by an attacker to run Telnet...

9.8CVSS6.9AI score0.01676EPSS
SaveExploits0References1
ICS
ICS
added 2020/06/18 12:00 a.m.193 views

Baxter Sigma Spectrum Infusion Pumps (Update B)

1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Baxter Equipment: Sigma Spectrum Infusion Pumps Vulnerabilities: Use of Hard-coded Password, Cleartext Transmission of Sensitive Data, Incorrect Permission Assignment for Critical Resource, Operation on...

9.8CVSS7.9AI score0.02098EPSS
SaveExploits1References5
ICS
ICS
added 2019/10/01 6:00 a.m.251 views

Interpeak IPnet TCP/IP Stack (Update E)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION : Exploitable remotely/low attack complexity/public exploits are available Vendor : ENEA, Green Hills Software, ITRON, IP Infusion, Wind River Equipment : OSE by ENEA, INTEGRITY RTOS by Green Hills Software, ITRON, ZebOS by IP Infusion, and...

9.8CVSS9.3AI score0.84177EPSS
SaveExploits7References10
CNVD
CNVD
added 2019/06/21 12:00 a.m.10 views

BD Alaris Gateway Workstation Arbitrary File Upload Vulnerability

BD Alaris Gateway Workstation is an intelligent infusion system, BD Alaris GS is a medical syringe pump, and BD Alaris GH is a medical syringe pump. The BD Alaris Gateway Workstation has arbitrary file upload vulnerabilities. An attacker could use these vulnerabilities to upload arbitrary files t...

10CVSS7.8AI score0.02528EPSS
SaveExploits0References1
HackRead
HackRead
added 2019/06/14 8:58 p.m.150 views

Vulnerable infusion pumps can be remotely accessed to change dosages

By Waqas Critical Bug in Medical Infusion Pumps lets Attacker Remotely install Unauthorized Firmware to Change Medication Dosages. Researchers at CyberMDX, a healthcare security firm, have identified two different vulnerabilities in Becton Dickinson Alaris Gateway Workstations AGW used by hospita...

1.3AI score
SaveExploits0
ThreatPost
ThreatPost
added 2019/06/13 6:41 p.m.175 views

Max-Severity Bug in Infusion Pump Gateway Puts Lives at Risk

Researchers have disclosed two separate vulnerabilities within the Becton Dickinson Alaris Gateway Workstation for medical infusion pumps in hospitals, one carrying a critical rating of 10 out of 10 on the CVSS v.3 severity scale. Alaris Gateway Workstations power, monitor and control infusion...

7.5CVSS0.02528EPSS
SaveExploits0References8