Lucene search
+L

1219 matches found

Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.21 views

Siemens Simatic Unspecified Vulnerability

The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms and hijack sessions via unspecified vectors. File data ot500041.nasl...

8.3CVSS5.5AI score0.02744EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.27 views

Siemens Simatic Cross-Site Request Forgery (CSRF)

Cross-site request forgery CSRF vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. File data ot500269.nasl...

5.8CVSS6AI score0.01344EPSS
SaveExploits1References5
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.18 views

Abb Fox515t Improper Input Validation

An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrie...

2.1CVSS2.8AI score0.00391EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Siemens Simatic Unspecified Vulnerability

A vulnerability has been identified in SIMATIC S7-400 incl. F CPU hardware version 4.0 and below All versions, SIMATIC S7-400 incl. F CPU hardware version 5.0 All firmware versions V5.2, SIMATIC S7-400H CPU hardware version 4.5 and below All versions. The affected CPUs improperly validate S7...

5CVSS3.1AI score0.02512EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Rockwellautomation Micrologix Unspecified Vulnerability

Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors. File data ot500152.nasl...

4CVSS4.9AI score0.01604EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.28 views

Siemens Apogee Exposure of Sensitive Information to an Unauthorized Actor

Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors. File data ot500249.nasl...

3.6CVSS2.5AI score0.00313EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.21 views

Rockwellautomation Arena Exposure of Sensitive Information to an Unauthorized Actor

Rockwell Automation Arena Simulation Software versions 16.00.00 and earlier contain an INFORMATION EXPOSURE CWE-200. A maliciously crafted Arena file opened by an unsuspecting user may result in the limited exposure of information related to the targeted workstation. File data ot500274.nasl...

4.3CVSS2.2AI score0.05777EPSS
SaveExploits0References7
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.15 views

VMware OT Asset Information

This plugin returns information for a VMware asset in an OT environment. File data ot500019.nasl...

1.6AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.31 views

Schneider-electric Modicon Improper Access Control

A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus. File data ot500328.n...

7.5CVSS5.3AI score0.03808EPSS
SaveExploits1References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Rockwellautomation Rslinx Improper Restriction of Operations within the Bounds of a Memory Buffer

Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service application crash or possibly execute arbitrary code via a malformed .eds file...

9.3CVSS6.2AI score0.07588EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.28 views

Intel Atom Exposure of Sensitive Information to an Unauthorized Actor

Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Stor...

4.9CVSS4AI score0.60631EPSS
SaveExploits3References147
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.20 views

Siemens Simatic Improper Input Validation

Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service STOP mode transition via crafted packets on TCP port 102. File data ot500287.nasl...

7.8CVSS5AI score0.06371EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.26 views

Rockwellautomation Micrologix Uncontrolled Resource Consumption

An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a device power cycle...

7.8CVSS2.9AI score0.0472EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Rockwellautomation Micrologix Uncontrolled Resource Consumption

An exploitable insufficient resource pool vulnerability exists in the session communication functionality of Allen Bradley Micrologix 1400 Series B Firmware 21.2 and before. A specially crafted stream of packets can cause a flood of the session resource pool resulting in legitimate connections to...

5CVSS1.9AI score0.06EPSS
SaveExploits1References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Rockwellautomation Factorytalk Improper Restriction of Operations within the Bounds of a Memory Buffer

The FactoryTalk FT RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service out-of-bounds read via a crafted packet. File data ot500151.nasl...

5CVSS4.9AI score0.03534EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.23 views

Enea Ose Exposure of Sensitive Information to an Unauthorized Actor

The kernel in ENEA OSE on the Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier performs network-beacon broadcasts, which allows remote attackers to obtain potentially sensitive informati...

10CVSS4.1AI score0.03263EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.17 views

Rockwellautomation Connected Unspecified Vulnerability

Rockwell Automation Connected Components Workbench CCW before 7.00.00 allows remote attackers to cause a denial of service application crash or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler. File data ot500145.nasl...

7.5CVSS6.7AI score0.11EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.25 views

Rockwellautomation Panelview Improper Access Control

In Rockwell Automation PanelView 5510 all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later, a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and...

10CVSS3.9AI score0.04597EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.25 views

Abb Fox515t Exposure of Sensitive Information to an Unauthorized Actor

The embedded web server on ABB Fox515T 1.0 devices is vulnerable to Local File Inclusion. It accepts a parameter that specifies a file for display or for use as a template. The filename is not validated; an attacker could retrieve any file. File data ot500275.nasl...

5CVSS2AI score0.01329EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.26 views

Schneider-electric Modicon Improper Handling of Exceptional Conditions

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP...

4CVSS2.3AI score0.00959EPSS
SaveExploits0References2
Rows per page