Lucene search
+L

1213 matches found

Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.23 views

Rockwellautomation Rslinx Improper Restriction of Operations within the Bounds of a Memory Buffer

Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers to execute arbitrary code via a crafted CSV file. File data ot500113.nasl...

6.9CVSS6.9AI score0.01573EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.19 views

Rockwellautomation Micrologix Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Cross-site scripting XSS vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. File data ot500043.nasl...

4.3CVSS3.8AI score0.02836EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.23 views

Abb Pm554-tp-eth Uncontrolled Resource Consumption

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. File data ot500200.nasl...

7.5CVSS2.5AI score0.03671EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.22 views

Schneider-electric Modicon Use of Insufficiently Random Values

A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...

9.1CVSS2.6AI score0.3182EPSS
Exploits5References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.20 views

Schneider-electric Modicon Exposure of Sensitive Information to an Unauthorized Actor

A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module. File data ot500293.nas...

5CVSS1.4AI score0.01709EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.20 views

Enea Ose Exposure of Sensitive Information to an Unauthorized Actor

The kernel in ENEA OSE on the Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier performs network-beacon broadcasts, which allows remote attackers to obtain potentially sensitive informati...

10CVSS4.1AI score0.03263EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.18 views

Mitsubishi Controller Asset Information

This plugin returns asset information for a Mitsubishi controller. File data ot500010.nasl...

1.1AI score
Exploits0
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.25 views

Schneider-electric Modicon Unspecified Vulnerability

A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller. File data...

7.5CVSS4.2AI score0.35039EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.31 views

Schneider-electric Modicon Out-of-bounds Read

A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus. File data...

5CVSS2.7AI score0.03413EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.19 views

Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions

A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. File data ot500243.nasl...

5CVSS3.2AI score0.02304EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.14 views

Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus File data ot500300.nasl...

5CVSS3.2AI score0.01821EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.18 views

Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. File data ot500099.nasl...

5CVSS3.5AI score0.01582EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.20 views

Schneider-electric Modicon Improper Handling of Exceptional Conditions

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol. File data...

4CVSS2.2AI score0.24374EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.23 views

Schneider-electric Modicon Improper Check for Unusual or Exceptional Conditions

A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. File data ot500291.nasl...

5CVSS3.3AI score0.02236EPSS
Exploits1References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.25 views

Schneider-electric Modicon Improper Handling of Exceptional Conditions

A CWE-248: Uncaught Exception vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules all firmware versions, which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol. File data ot500193.na...

4CVSS2.3AI score0.00959EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.35 views

Schneider-electric Somachine Unspecified Vulnerability

An Incorrect Default Permissions CWE-276 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic. File...

5.5CVSS2.7AI score0.0031EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.21 views

Schneider-electric Concept Improper Restriction of Operations within the Bounds of a Memory Buffer

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. File data ot500029.nasl...

9.3CVSS6.3AI score0.22293EPSS
Exploits10References6
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.17 views

Siemens Simatic Unspecified Vulnerability

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service defect-mode transition via crafted Profinet packets. File data ot500130.nasl...

6.1CVSS5.4AI score0.0101EPSS
Exploits0References4
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.34 views

Schneider-electric Modicon Missing Authentication for Critical Function

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...

8.2CVSS1.8AI score0.0124EPSS
Exploits0References2
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:0 a.m.29 views

Windriver Vxworks Improper Restriction of Operations within the Bounds of a Memory Buffer

Wind River VxWorks 6.9.4 and vx7 has a Buffer Overflow in the TCP component issue 4 of 4. There is an IPNET security vulnerability: TCP Urgent Pointer state confusion due to race condition. File data ot500063.nasl...

6.8CVSS2.7AI score0.03189EPSS
Exploits0References9
Rows per page