1740 matches found
Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers Improper Check For Unusual or Exceptional Conditions (CVE-2022-45788)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
Schneider Electric EcoStruxure Control Expert, Process Expert, Modicon M340, M580 and M580 CPU Authentication Bypass By Capture-Replay (CVE-2022-45789)
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert Versions pri...
Wago Multiple Products Web-based Management Origin Validation Error (CVE-2022-45139)
A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of...
Schneider Electric Modicon Missing Authentication for Critical Function (CVE-2019-6820)
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration IP address, network mask and gateway IP address when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC...
Schneider Electric Modicon Incorrect Default Permissions (CVE-2018-7822)
An Incorrect Default Permissions CWE-276 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic. This...
Schneider Electric Modicon Out-of-bounds Write (CVE-2020-7524)
Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller V5.0.0.7 and prior which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4...
Siemens (CVE-2018-11452) (deprecated)
Plugin deprecated because en ethernetmodule is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. @DEPRECATED@ Disabled on 2023/05/15. Deprecated because en...
Siemens SCALANCE X-200RNA Switch Devices Integer Overflow or Wraparound (CVE-2019-16905)
OpenSSH 7.7 through 7.9 and 8.x before 8.1, when compiled with an experimental key type, has a pre-authentication integer overflow if a client or server is configured to use a crafted XMSS key. This leads to memory corruption and local code execution because of an error in the XMSS key parsing...
Schneider Electric Modicon Cleartext Transmission of Sensitive Information (CVE-2020-7488)
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. This plugin only works with Tenable.ot. Please visit...
Schneider Electric Modicon X80 Exposure of Sensitive Information to an Unauthorized Actor (CVE-2021-22749)
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially...
Schneider Electric Modicon PLCs Use of Insufficiently Random Values (CVE-2017-6026)
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization an...
Schneider Electric Modicon Uncontrolled Resource Consumption (CVE-2013-2763)
DISPUTED The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service resource consumption via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it could not be duplicated and an attacker could not remotely exploit this observed behavior t...
Schneider Electric Modicon Insufficient Verification of Data Authenticity (CVE-2020-7487)
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Schneider Electric Modicon M221 Programmable Logic Controller Missing Encryption of Sensitive Data (CVE-2020-7567)
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...
Schneider Electric EcoStruxure Machine Expert Injection (CVE-2020-7489)
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection' vulnerability exists on EcoStruxure Machine Expert Basic or SoMachine Basic programming software versions in security notification. The result of this vulnerability, DLL substitution, could...
Schneider Electric Modicon PLCs Insufficiently Protected Credentials (CVE-2017-6028)
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials...
Wago PLC Cycle Time Influences Uncontrolled Resource Consumption (CVE-2019-10953)
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. This plugin only works with Tenable.ot. Please visit...
Siemens SICAM PQ Analyzer Unquoted Search Path or Element (CVE-2021-45460)
A vulnerability has been identified in SICAM PQ Analyzer All versions V3.18. A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate proces...
Siemens SIPROTEC 5 Devices Improper Input Validation (CVE-2021-41769)
A vulnerability has been identified in SIPROTEC 5 6MD85 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD86 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MD89 devices CPU variant CP300 All versions V8.83, SIPROTEC 5 6MU85 devices CPU variant CP300 All versions V8.83, SIPROT...
Siemens Buffer Over-Read in Wibu-Systems CodeMeter Runtime (CVE-2021-20094)
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...