Out-of-bounds Write vulnerability exists in Modicon M218 Logic Controller (V5.0.0.7 and prior) which could cause Denial of Service when sending specific crafted IPV4 packet to the controller: Sending a specific IPv4 protocol package to Schneider Electric Modicon M218 Logic Controller can cause IPv4 devices to go down. The device does not work properly and must be powered back on to return to normal.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(500853);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/24");
script_cve_id("CVE-2020-7524");
script_name(english:"Schneider Electric Modicon Out-of-bounds Write (CVE-2020-7524)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"Out-of-bounds Write vulnerability exists in Modicon M218 Logic
Controller (V5.0.0.7 and prior) which could cause Denial of Service
when sending specific crafted IPV4 packet to the controller: Sending a
specific IPv4 protocol package to Schneider Electric Modicon M218
Logic Controller can cause IPv4 devices to go down. The device does
not work properly and must be powered back on to return to normal.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://www.se.com/ww/en/download/document/SEVD-2020-224-03/");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-7524");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(787);
script_set_attribute(attribute:"vuln_publication_date", value:"2020/08/31");
script_set_attribute(attribute:"patch_publication_date", value:"2020/08/31");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/03/01");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m218_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"current");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:modicon_m218_series_firmware" :
{"versionEndIncluding" : "5.0.0.7", "family" : "ModiconM218"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Vendor | Product | Version | CPE |
---|---|---|---|
schneider-electric | modicon_m218_series_firmware | cpe:/o:schneider-electric:modicon_m218_series_firmware |