1740 matches found
Schneider Electric Wiser Smart Missing Encryption of Sensitive Data (CVE-2022-30237)
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 V4.5 and prior This plugin only works with Tenable.ot. Please visit...
ABB Central Licensing System Uncontrolled Resource Consumption (CVE-2020-8475)
For the Central Licensing Server component used in ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to...
ABB AC500 Allocation of Resources Without Limits or Throttling (CVE-2020-24685)
An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service DoS vulnerability. Vulnerability allows attacker to stop the PLC. After stopping ERR LED flashing red, physical access to the PLC is required in order to restart the application. This...
ABB Central Licensing System Exposure of Sensitive Information to an Unauthorized Actor (CVE-2020-8481)
For ABB products ABB Ability System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody...
Rockwell Automation products using GoAhead Web Server Use After Free (CVE-2019-5096)
An exploitable code execution vulnerability exists in the processing of multi-part/form-data requests within the base GoAhead web server application in versions v5.0.1, v.4.1.1 and v3.6.5. A specially crafted HTTP request can lead to a use-after-free condition during the processing of this reques...
Rockwell Automation products using GoAhead Web Server Loop with Unreachable Exit Condition (CVE-2019-5097)
A denial-of-service vulnerability exists in the processing of multi- part/form-data requests in the base GoAhead web server application in versions v5.0.1, v.4.1.1 and v3.6.5. A specially crafted HTTP request can lead to an infinite loop in the process. The request can be unauthenticated in the...
Siemens SCALANCE S-600 Improper Neutralization of Script-Related HTML Tags in a Web Page (CVE-2019-6585)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1, SCALANCE S627-2M All version...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13926)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold r...
Siemens SCALANCE S-600 Uncontrolled Resource Consumption (CVE-2019-13925)
A vulnerability has been identified in SCALANCE S602 All versions = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and = V3.0 and V4.1. Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. This plug...
Siemens SCALANCE X-200RNA Switch Devices Path Traversal (CVE-2019-6111)
An issue was discovered in OpenSSH 7.9. Due to the scp implementation being derived from 1983 rcp, the server chooses which files/directories are sent to the client. However, the scp client only performs cursory validation of the object name returned only directory traversal attacks are prevented...
Mitsubishi Electric MELSEC iQ-R, iQ-L Series and MELIPC Series Improper Resource Shutdown or Release (CVE-2022-33324)
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU Firmware versions 32 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Firmware versions 65 and prior, Mitsubishi Electric Corporation MELSEC iQ...
Tridium Niagara AX Insufficiently Protected Credentials (CVE-2012-3025)
The default configuration of Tridium Niagara AX Framework through 3.6 uses a cleartext base64 format for transmission of credentials in cookies, which allows remote attackers to obtain sensitive information by sniffing the network. This plugin only works with Tenable.ot. Please visit...
Tridium Niagara AX Path Traversal (CVE-2012-4701)
Directory traversal vulnerability in Tridium Niagara AX 3.5, 3.6, and 3.7 allows remote attackers to read sensitive files, and consequently execute arbitrary code, by leveraging 1 valid credentials or 2 the guest feature. This plugin only works with Tenable.ot. Please visit...
Tridium Niagara AX Path Traversal (CVE-2012-4027)
Directory traversal vulnerability in Tridium Niagara AX Framework allows remote attackers to read files outside of the intended images, nav, and px folders by leveraging incorrect permissions, as demonstrated by reading the config.bog file. This plugin only works with Tenable.ot. Please visit...
Tridium Niagara Enterprise Security, Niagara AX, and Niagara 4 Improper Neutralization of Input During Web Page Generation (CVE-2018-18985)
Tridium Niagara Enterprise Security 2.3u1, all versions prior to 2.3.118.6, Niagara AX 3.8u4, all versions prior to 3.8.401.1, Niagara 4.4u2, all versions prior to 4.4.93.40.2, and Niagara 4.6, all versions prior to 4.6.96.28.4 a cross-site scripting vulnerability has been identified that may all...
Mitsubishi Electric MELSEC iQ-F Series Plaintext Storage of a Password (CVE-2023-0457)
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC CPU modules all models all versions, FX5UJ CPU modules all models all versions, FX5S CPU modules all models all versions, FX5-ENET all versions and FX5-ENET/IP all versions allows a remote...
Siemens SCALANCE W1750D Command Injection (CVE-2018-7084)
A command injection vulnerability is present that permits an unauthenticated user with access to the Aruba Instant web interface to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete...
Siemens TCP Event Service of SCALANCE And RUGGEDCOM Devices Improper Input Validation (CVE-2022-31766)
A vulnerability has been identified in RUGGEDCOM RM1224 LTE4G EU All versions = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 = V1.1.0 V2.0, SCALANCE WUM766-1 US All...
ABB SMU615 Improper Initialization (CVE-2021-22283)
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...
Wago Multiple Products Web-based Management Cross-site Scripting (CVE-2022-45137)
The configuration backend of the web-based management is vulnerable to reflected XSS Cross-Site Scripting attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability. This plugin only works with Tenable.ot. Please visit...