296 matches found
CVE-2019-6572: Exposure of Sensitive Information to an Unauthorized Actor
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15.1 Update 1, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15.1 Update 1, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F All versions V15.1 Update 1, SIMATIC WinCC...
CVE-2019-10922: Missing Authentication for Critical Function
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier All versions, SIMATIC PCS 7 V8.1 and newer All versions, SIMATIC WinCC V7.2 and earlier All versions, SIMATIC WinCC V7.3 and newer All versions. An attacker with network access to affected installations, which are configured...
CVE-2019-6576: Undefined Security Weakness
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15.1 Update 1, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15.1 Update 1, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F All versions V15.1 Update 1, SIMATIC WinCC...
CVE-2019-6577: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15.1 Update 1, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15.1 Update 1, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F All versions V15.1 Update 1, SIMATIC WinCC...
ICSA-19-134-02 Siemens SIMATIC WinCC and SIMATIC PCS 7
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC WinCC and SIMATIC PCS 7 Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an...
CVE-2019-6575
CVE-2019-6575 affects Siemens industrial products using OPC UA, including SIMATIC CP443-1 OPC UA, ET 200 Open Controller CPU 1515SP PC2, HMI Outdoor Panels (7"/15"), HMI Comfort Panels (4"–22"), KTP Mobile Panels, IPC DiagMonitor, NET PC Software, RF188C, RF600R, S7‑1500 family, WinCC OA/Runtime,...
WIBU SYSTEMS AG WibuKey Digital Rights Management (Update B)
1. EXECUTIVE SUMMARY CVSS v3 10.0 --------- Begin Update B Part 1 of 4 --------- ATTENTION: Exploitable remotely/low skill level to exploit/public exploits available Vendor: WIBU-SYSTEMS AG Equipment: WibuKey Digital Rights Management DRM --------- End Update B Part 1 of 4 ---------...
Siemens SIMATIC WinCC/Audit Viewer Detection (Windows SMB Login)
SMB login-based detection of Siemens SIMATIC WINCC Audit/Viewer. SPDX-FileCopyrightText: 2019 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only include"pluginfeedinfo.inc";...
Siemens SIMATIC WinCC/Audit Viewer Detection (Windows SMB Login)
Detects the installed version of Siemens SIMATIC WinCC/Audit Viewer for Windows This VT is a duplicate of the existing VT SPDX-FileCopyrightText: 2019 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders...
CVE-2018-13814: Improper Neutralization of CRLF Sequences in HTTP Headers
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V14, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V14, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions V14, SIMATIC WinCC Runtime Advanced All versions V14,...
PT-2018-12199
Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 4" - 22" versions prior to V15 Update 4 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15 Update 4 SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V15 Upda...
PT-2018-12198
Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 4" - 22" versions prior to V15 Update 4 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15 Update 4 SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V15 Upda...
CVE-2018-13813: URL Redirection to Untrusted Site
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15 Update 4, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15 Update 4, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions V15 Update 4, SIMATIC WinCC Runtime...
CVE-2018-13812: Improper Limitation of a Pathname to a Restricted Directory
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" All versions V15 Update 4, SIMATIC HMI Comfort Outdoor Panels 7" & 15" All versions V15 Update 4, SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions V15 Update 4, SIMATIC WinCC Runtime...
PT-2018-12200
Name of the Vulnerable Software and Affected Versions SIMATIC HMI Comfort Panels 4" - 22" versions prior to V14 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V14 SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F versions prior to V14 SIMATIC WinCC Runtime...
The vulnerability of the TCP-server in the SIMATIC WinCC SCADA system allows a intruder to increase their privileges.
The vulnerability of the TCP-server in the SIMATIC WinCC SCADA system is related to access control errors. Exploiting this vulnerability can allow an attacker, operating remotely, to enhance their privileges by using the TCP-port 5678...
CVE-2018-13799
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior All versions V3.14-P021. Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could...
CVE-2018-13799
The CVE-2018-13799 vulnerability affects SIMATIC WinCC OA V3.14 and earlier (
Improper access control
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior All versions V3.14-P021. Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could...
CVE-2018-13799
A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior All versions V3.14-P021. Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could...