Lucene search
+L

296 matches found

CVE
CVE
•added 2021/11/09 11:32 a.m.•103 views

CVE-2021-40359

CVE-2021-40359 is a path traversal vulnerability in Siemens products (OpenPCS 7, SIMATIC BATCH, SIMATIC NET PC Software, SIMATIC PCS 7, SIMATIC Route Control, SIMATIC WinCC, etc.). The issue arises from improper neutralization of special elements in pathnames when downloading files, allowing an a...

7.7CVSS7.2AI score0.01174EPSS
SaveExploits0References1Affected Software5
CNNVD
CNNVD
•added 2021/11/09 12:00 a.m.•19 views

Siemens SIMATIC PCS 7和SIMATIC WinCC 路径遍历漏洞

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company. SIMATIC PCS 7 is a process control system and SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. A path traversal vulnerability exists in SIMATIC PCS 7 and SIMATIC WinCC. The...

9.9CVSS5.8AI score0.01274EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•2 views

CVE-2021-40364: Insertion of Sensitive Information into Log File

A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3 UC04, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions...

5.5CVSS5.6AI score0.0024EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•6 views

CVE-2021-40359: Improper Limitation of a Pathname to a Restricted Directory

A vulnerability has been identified in OpenPCS 7 V8.2 All versions, OpenPCS 7 V9.0 All versions V9.0 Upd4, OpenPCS 7 V9.1 All versions, SIMATIC BATCH V8.2 All versions, SIMATIC BATCH V9.0 All versions, SIMATIC BATCH V9.1 All versions, SIMATIC NET PC Software V14 All versions, SIMATIC NET PC...

7.7CVSS5.6AI score0.01174EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/11/09 12:00 a.m.•2 views

CVE-2021-40358: Improper Limitation of a Pathname to a Restricted Directory

A vulnerability has been identified in SIMATIC PCS 7 V8.2 All versions, SIMATIC PCS 7 V9.0 All versions V9.0 SP3 UC04, SIMATIC PCS 7 V9.1 All versions V9.1 SP1, SIMATIC WinCC V15 and earlier All versions V15 SP1 Update 7, SIMATIC WinCC V16 All versions V16 Update 5, SIMATIC WinCC V17 All versions...

9.9CVSS5.6AI score0.01274EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2021/11/09 12:00 a.m.•17 views

PT-2021-22877 · Siemens · Openpcs 7 +5

Name of the Vulnerable Software and Affected Versions: OpenPCS 7 versions 7.0 through 9.1 SIMATIC BATCH versions 8.2 through 9.1 SIMATIC NET PC Software versions 14 through 17 SIMATIC PCS 7 versions 8.2 through 9.1 SIMATIC Route Control versions 8.2 through 9.1 SIMATIC WinCC versions 7.4 through ...

7.7CVSS7.3AI score0.01174EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2021/11/09 12:00 a.m.•21 views

Siemens SIMATIC PCS 7和SIMATIC WinCC 路径遍历漏洞

Siemens SIMATIC PCS 7 and SIMATIC WinCC are both products of Siemens, a German company. SIMATIC PCS 7 is a process control system and SIMATIC WinCC is an automated data acquisition and monitoring SCADA system. A path traversal vulnerability exists in SIMATIC PCS 7 and SIMATIC WinCC, which stems...

7.7CVSS5.8AI score0.01174EPSS
SaveExploits0References4
ICS
ICS
•added 2021/11/09 12:00 a.m.•170 views

Siemens SIMATIC WinCC (Update E)

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

9.9CVSS7.5AI score0.01274EPSS
SaveExploits0References12
attackerkb
attackerkb
•added 2021/05/12 2:15 p.m.•12 views

CVE-2021-25662

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS7.4AI score0.0164EPSS
SaveExploits0References3
CVE
CVE
•added 2021/05/12 1:18 p.m.•107 views

CVE-2021-27384

CVE-2021-27384 is a concrete SmartVNC vulnerability: an out-of-bounds memory access in the device layout handler could allow code execution. Affected Siemens products include SmartVNC-enabled HMI/WinCC components (e.g., SIMATIC HMI Comfort Outdoor Panels, KTP Mobile Panels, WinCC Runtime Advanced...

9.8CVSS9.3AI score0.02559EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•4 views

CVE-2021-25660: Access of Memory Location After End of Buffer

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.6AI score0.00969EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•7 views

CVE-2021-25662: Improper Handling of Exceptional Conditions

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.7AI score0.0164EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/05/12 12:00 a.m.•4 views

CVE-2021-27386: Missing Release of Memory after Effective Lifetime

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...

7.5CVSS5.6AI score0.01792EPSS
SaveExploits0References36
CNNVD
CNNVD
•added 2021/05/11 12:00 a.m.•16 views

Siemens SIMATIC WinCC 安全漏洞

Siemens SIMATIC WinCC is an automated data acquisition and monitoring SCADA system from Siemens, Germany. A security vulnerability exists in SIMATIC WinCC. The vulnerability stems from an out-of-scope memory access vulnerability in the program, which could lead to code execution...

7.5CVSS7.5AI score0.01148EPSS
SaveExploits0References6
CNVD
CNVD
•added 2021/02/20 12:00 a.m.•91 views

Siemens SIMATIC WinCC Bypass Authentication Vulnerability

Siemens SIMATIC WinCC is an automated data acquisition and monitoring SCADA system from Siemens, Germany. A security vulnerability exists in Siemens SIMATIC WinCC. The vulnerability is caused due to an insecure password authentication process, which can be exploited by an attacker to bypass the...

5.5CVSS7.4AI score0.00336EPSS
SaveExploits0References1
NVD
NVD
•added 2021/02/09 5:15 p.m.•61 views

CVE-2020-10048

A vulnerability has been identified in SIMATIC PCS 7 All versions, SIMATIC WinCC All versions V7.5 SP2. Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing...

5.5CVSS0.00336EPSS
SaveExploits0References1
ICS
ICS
•added 2021/02/09 12:00 a.m.•80 views

SIMATIC WinCC Graphics Designer

1. EXECUTIVE SUMMARY CVSS v3 6.2 ATTENTION: Low skill level to exploit Vendor : Siemens Equipment: SIMATIC WinCC and PCS 7 Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker...

5.5CVSS5.9AI score0.00336EPSS
SaveExploits0References9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/02/09 12:00 a.m.•5 views

CVE-2020-10048: Authentication Bypass Using an Alternate Path or Channel

A vulnerability has been identified in SIMATIC PCS 7 All versions, SIMATIC WinCC All versions V7.5 SP2. Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing...

5.5CVSS5.7AI score0.00336EPSS
SaveExploits0References3
CNVD
CNVD
•added 2020/09/09 12:00 a.m.•19 views

Memory Corruption Vulnerability in Multiple Siemens Products

Siemens SIMATIC WinCC OA Open Architecture is a SCADA system from Siemens, Germany, and a component of the HMI series. The system is mainly used in industries such as rail transportation, building automation and public power supply.Information Server is used to report and visualize process data...

9.8CVSS6.8AI score0.0207EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/07/14 12:00 a.m.•6 views

CVE-2020-7592: Cleartext Transmission of Sensitive Information

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation incl. SIPLUS variants All versions, SIMATIC HMI Basic Panels 2nd Generation incl. SIPLUS variants All versions, SIMATIC HMI Comfort Panels incl. SIPLUS variants All versions, SIMATIC HMI KTP700F Mobile Arctic All...

6.5CVSS5.7AI score0.00332EPSS
SaveExploits0References3
Rows per page