Lucene search
+L

218 matches found

NVD
NVD
added 2018/04/23 4:29 p.m.21 views

CVE-2018-4847

A vulnerability has been identified in SIMATIC WinCC OA Operator iOS App All versions V1.4. Insufficient protection of sensitive information e.g. session key for accessing server in Siemens WinCC OA Operator iOS app could allow an attacker with physical access to the mobile device to read...

4.6CVSS4AI score0.00275EPSS
SaveExploits0References2
CVE
CVE
added 2018/04/23 4:0 p.m.53 views

CVE-2018-4847

The CVE concerns SIMATIC WinCC OA Operator iOS App (all versions prior to v1.4). Affected component: the app’s data directory where sensitive information (e.g., session keys) can be read if an attacker has physical access. Root cause: Insufficient protection of sensitive information leading to in...

4.6CVSS4AI score0.00275EPSS
SaveExploits0References2Affected Software1
CNVD
CNVD
added 2018/04/19 12:0 a.m.9 views

SIMATIC WinCC OA Operator iOS Information Disclosure Vulnerability

SIMATIC WinCC OA Operator iOS is an application that makes it easy to control SIMATIC WinCC OA devices from a mobile device. An information disclosure vulnerability exists in SIMATIC WinCC OA Operator iOS. It allows an attacker to read unencrypted data from the application's directory. A...

4.6CVSS5.8AI score0.00275EPSS
SaveExploits0References1
ICS
ICS
added 2018/04/19 12:0 a.m.50 views

Siemens SIMATIC WinCC OA Operator IOS App (Update A)

1. EXECUTIVE SUMMARY CVSS v3 4.0 Vendor : Siemens Equipment : SIMATIC WinCC OA iOS App Vulnerability : File and Directory Information Exposure. 2 UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-109-01 Siemens SIMATIC WinCC OA Operator iOS App that...

4.6CVSS4.3AI score0.00275EPSS
SaveExploits0References4
Prion
Prion
added 2018/03/20 2:29 p.m.17 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC WinCC OA UI for Android All versions V3.15.10, SIMATIC WinCC OA UI for iOS All versions V3.15.10. Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache...

3.8CVSS6AI score0.00427EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2018/03/20 2:29 p.m.20 views

CVE-2018-4844

A vulnerability has been identified in SIMATIC WinCC OA UI for Android All versions V3.15.10, SIMATIC WinCC OA UI for iOS All versions V3.15.10. Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache...

6.7CVSS6AI score0.00427EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2018/03/20 2:0 p.m.30 views

CVE-2018-4844

A vulnerability has been identified in SIMATIC WinCC OA UI for Android All versions V3.15.10, SIMATIC WinCC OA UI for iOS All versions V3.15.10. Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to other HMI project cache...

6AI score0.00427EPSS
SaveExploits0References2
ICS
ICS
added 2018/03/20 12:0 a.m.55 views

ICSA-18-081-01 Siemens SIMATIC WinCC OA UI Mobile App

CVSS v3 5.1 ATTENTION: Exploitable from an adjacent network. Vendor: Siemens Equipment: SIMATIC WinCC OA UI mobile app Vulnerability: Improper Access Control AFFECTED PRODUCTS Siemens reports that this vulnerability affects the following products: SIMATIC WinCC OA UI for Android: All versions pri...

6.7CVSS6.7AI score0.00427EPSS
SaveExploits0References9
ICS
ICS
added 2018/01/18 12:0 a.m.78 views

ICSA-18-018-01A Siemens SIMATIC WinCC Add-On (Update A)

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC WinCC Add-On Vulnerabilities: Stack-based Buffer Overflow, Improper Input Validation, Improper Restriction of Operations within the Bounds of a Memory Buffer, Security Features, Improper...

9.8CVSS10AI score0.04758EPSS
SaveExploits0References9
NVD
NVD
added 2017/08/30 7:29 p.m.52 views

CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server LDS before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 All versions V8.1 and earlier, SIMATIC WinCC All versions V7.4 SP1, SIMATIC WinCC Runtime...

8.2CVSS8.1AI score0.02904EPSS
SaveExploits0References4
Prion
Prion
added 2017/08/30 7:29 p.m.26 views

Design/Logic Flaw

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server LDS before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 All versions V8.1 and earlier, SIMATIC WinCC All versions V7.4 SP1, SIMATIC WinCC Runtime...

6.4CVSS8AI score0.02904EPSS
SaveExploits0References4Affected Software4
OSV
OSV
added 2017/08/30 7:29 p.m.12 views

CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server LDS before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 All versions V8.1 and earlier, SIMATIC WinCC All versions V7.4 SP1, SIMATIC WinCC Runtime...

8.2CVSS5.7AI score0.02904EPSS
SaveExploits0References4
CVE
CVE
added 2017/08/30 7:0 p.m.125 views

CVE-2017-12069

Summary: CVE-2017-12069 is an XXE vulnerability in the OPC UA Discovery Server handling of XML, affecting Siemens products using the OPC UA Stack (e.g., SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional, SIMATIC NET PC Software, and IT Production Suite). Root cause: Improper restri...

8.2CVSS8AI score0.02904EPSS
SaveExploits0References4Affected Software2
Cvelist
Cvelist
added 2017/08/30 7:0 p.m.49 views

CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server LDS before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 All versions V8.1 and earlier, SIMATIC WinCC All versions V7.4 SP1, SIMATIC WinCC Runtime...

8.1AI score0.02904EPSS
SaveExploits0References4
Prion
Prion
added 2017/08/08 12:29 a.m.23 views

Design/Logic Flaw

A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android All versions before V1.0.2.2 and SIMATIC WinCC Sm@rtClient for Android Lite All versions before V1.0.2.2. An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass...

4.6CVSS5.8AI score0.00317EPSS
SaveExploits0References2Affected Software2
NVD
NVD
added 2017/08/08 12:29 a.m.27 views

CVE-2017-6871

A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android All versions before V1.0.2.2 and SIMATIC WinCC Sm@rtClient for Android Lite All versions before V1.0.2.2. An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass...

5.4CVSS5.9AI score0.00317EPSS
SaveExploits0References2
ThreatPost
ThreatPost
added 2017/07/14 12:37 p.m.35 views

Siemens Patches Authentication Bypass Flaw in SiPass Server

A handful of vulnerabilities in Siemens’ SiPass integrated server have been patched, including one that allows an attacker to bypass authentication on the box. SiPass is the company’s integrated access control server managing physical access in a number of industries and use cases. The product...

7.5CVSS1.7AI score0.02065EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2017/05/19 12:0 a.m.83 views

Siemens SIMATIC WinCC (TIA Portal) 13 < 13 SP2 / 14 < 14 SP1 Multiple DoS

Binary data scadasiemenstiawincc13SP214SP1.nbin...

6AI score
SaveExploits0References6
Prion
Prion
added 2017/05/11 10:29 a.m.21 views

Design/Logic Flaw

A vulnerability was discovered in Siemens SIMATIC WinCC V7.3 before Upd 11 and V7.4 before SP1, SIMATIC WinCC Runtime Professional V13 before SP2 and V14 before SP1, SIMATIC WinCC TIA Portal Professional V13 before SP2 and V14 before SP1 that could allow an authenticated, remote attacker who is...

4CVSS5AI score0.01923EPSS
SaveExploits0References3Affected Software3
CVE
CVE
added 2017/05/11 10:0 a.m.63 views

CVE-2017-6867

CVE-2017-6867 affects Siemens SIMATIC WinCC family (WinCC v7.3 before Update 11, WinCC v7.4 before SP1; WinCC Runtime Professional v13 before SP2, v14 before SP1; WinCC (TIA Portal) Professional v13 before SP2, v14 before SP1). The issue is improper input validation allowing an authenticated remo...

4.9CVSS5.4AI score0.01923EPSS
SaveExploits0References3Affected Software3
Rows per page
Query Builder