113 matches found
CVE-2023-2187
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event"...
Format string
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string...
Design/Logic Flaw
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event"...
CVE-2023-2187
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event"...
CVE-2023-2186
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string...
CVE-2023-2186
CVE-2023-2186 affects Triangle MicroWorks SCADA Data Gateway
CVE-2023-2186
On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string...
Triangle MicroWorks SCADA Data Gateway 安全漏洞
Triangle Microworks Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle Microworks, Inc. A security vulnerability exists in Triangle MicroWorks SCADA Data Gateway v5.01.03 and earlier versions, which originates from an unauthenticated attacker being able to send a...
The vulnerability of the Restore Workspace function in SCADA systems’ SCADA Data Gateway (SDG) allows a intruder to execute arbitrary code.
The vulnerability of the Restore Workspace function in SCADA systems’ SCADA Data Gateway SDG is related to incorrect restrictions on the path name to the restricted access catalog. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code...
PT-2023-3042 · Triangle Microworks · Scada Data Gateway
Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks' SCADA Data Gateway version = v5.01.03 Description: The issue is related to the lack of authentication for a critical function in the WebMonitor component of the SCADA Data Gateway. An unauthenticated attacker can send...
PT-2023-3043 · Triangle Microworks · Scada Data Gateway
Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks' SCADA Data Gateway version = v5.01.03 Description: The issue is related to the use of uncontrolled format strings in the GTWWebMonitor.exe executable file of the SCADA Data Gateway system. An unauthenticated attacker can...
(Pwn2Own) Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the...
PT-2023-5841 · Triangle Microworks · Triangle Microworks Scada Data Gateway
Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks SCADA Data Gateway affected versions not specified Description: This issue allows remote attackers to write arbitrary files on affected installations, potentially enabling them to execute code in the context of root. The...
(Pwn2Own) Triangle MicroWorks SCADA Data Gateway DNP3 Type Confusion Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of data set elements. The issue results from the lac...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10611
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...
CVE-2020-10613
Triangle MicroWorks SCADA Data Gateway is affected by CVE-2020-10613 (and related CVEs) in versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122 due to an out-of-bounds read from improper validation of user-supplied data in DNP3 Data Sets. The vulnerability allows remote attackers to disclose sensitiv...
CVE-2020-10615
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...