Lucene search
+L

135 matches found

CNNVD
CNNVD
•added 2023/06/07 12:00 a.m.•24 views

Triangle MicroWorks SCADA Data Gateway 安全漏洞

Triangle Microworks Triangle MicroWorks SCADA Data Gateway is a SCADA data gateway product from Triangle Microworks, Inc. A security vulnerability exists in Triangle MicroWorks SCADA Data Gateway v5.01.03 and earlier versions, which originates from an unauthenticated attacker being able to send a...

5.3CVSS5.7AI score0.00593EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/06/07 12:00 a.m.•2 views

CVE-2023-2187: Missing Authentication for Critical Function

On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event"...

5.3CVSS6AI score0.00593EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/06/07 12:00 a.m.•0 views

CVE-2023-2186: Use of Externally-Controlled Format String

On Triangle MicroWorks' SCADA Data Gateway version = v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string...

9.8CVSS7.9AI score0.00706EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2023/05/10 12:00 a.m.•15 views

The vulnerability of the Restore Workspace function in SCADA systems’ SCADA Data Gateway (SDG) allows a intruder to execute arbitrary code.

The vulnerability of the Restore Workspace function in SCADA systems’ SCADA Data Gateway SDG is related to incorrect restrictions on the path name to the restricted access catalog. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code...

9CVSS7.4AI score0.02298EPSS
SaveExploits0References6Affected Software1
Positive Technologies
Positive Technologies
•added 2023/04/29 12:00 a.m.•16 views

PT-2023-3043 · Triangle Microworks · Scada Data Gateway

Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks' SCADA Data Gateway version = v5.01.03 Description: The issue is related to the use of uncontrolled format strings in the GTWWebMonitor.exe executable file of the SCADA Data Gateway system. An unauthenticated attacker can...

9.8CVSS9.2AI score0.00706EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2023/04/29 12:00 a.m.•18 views

PT-2023-3042 · Triangle Microworks · Scada Data Gateway

Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks' SCADA Data Gateway version = v5.01.03 Description: The issue is related to the lack of authentication for a critical function in the WebMonitor component of the SCADA Data Gateway. An unauthenticated attacker can send...

5.3CVSS5.3AI score0.00593EPSS
SaveExploits0References5
Zero Day Initiative
Zero Day Initiative
•added 2023/04/14 12:00 a.m.•33 views

(Pwn2Own) Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the...

7.2CVSS7.2AI score0.02298EPSS
SaveExploits0
Positive Technologies
Positive Technologies
•added 2023/02/24 12:00 a.m.•18 views

PT-2023-5841 · Triangle Microworks · Triangle Microworks Scada Data Gateway

Name of the Vulnerable Software and Affected Versions: Triangle MicroWorks SCADA Data Gateway affected versions not specified Description: This issue allows remote attackers to write arbitrary files on affected installations, potentially enabling them to execute code in the context of root. The...

6.2CVSS7.4AI score0.013EPSS
SaveExploits0References8
Zero Day Initiative
Zero Day Initiative
•added 2020/04/16 12:00 a.m.•41 views

(Pwn2Own) Triangle MicroWorks SCADA Data Gateway DNP3 Type Confusion Remote Code Execution Vulnerability

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of data set elements. The issue results from the lac...

9.8CVSS3.9AI score0.05226EPSS
SaveExploits0References1
OSV
OSV
•added 2020/04/15 7:15 p.m.•15 views

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.8CVSS7.6AI score0.05226EPSS
SaveExploits0References2
NVD
NVD
•added 2020/04/15 7:15 p.m.•38 views

CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...

7.5CVSS7.8AI score0.02493EPSS
SaveExploits0References2
NVD
NVD
•added 2020/04/15 7:15 p.m.•45 views

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.8CVSS9.8AI score0.05226EPSS
SaveExploits0References2
Cvelist
Cvelist
•added 2020/04/15 6:36 p.m.•33 views

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.7AI score0.05226EPSS
SaveExploits0References2
CVE
CVE
•added 2020/04/15 6:30 p.m.•68 views

CVE-2020-10613

Triangle MicroWorks SCADA Data Gateway is affected by CVE-2020-10613 (and related CVEs) in versions 2.41.0213–4.0.122 and 3.02.0697–4.0.122 due to an out-of-bounds read from improper validation of user-supplied data in DNP3 Data Sets. The vulnerability allows remote attackers to disclose sensitiv...

7.5CVSS7.3AI score0.02493EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2020/04/15 6:28 p.m.•40 views

CVE-2020-10615

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...

7.6AI score0.02568EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/15 12:00 a.m.•5 views

CVE-2020-10613: Out-of-bounds Read

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is no...

7.5CVSS6.4AI score0.02493EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/15 12:00 a.m.•5 views

CVE-2020-10615: Stack-based Buffer Overflow

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication ...

7.5CVSS7.6AI score0.02568EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/04/15 12:00 a.m.•5 views

CVE-2020-10611: Access of Resource Using Incompatible Type

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this...

9.8CVSS8.7AI score0.05226EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2014/07/17 12:00 a.m.•15 views

Triangle MicroWorks SCADA Data Gateway Detection (credentialed check)

Binary data scadaapptriangledatagatewayinstalled.nbin...

7.3AI score
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2014/07/07 12:00 a.m.•88 views

Triangle MicroWorks SCADA Data Gateway < 3.3.729 Heartbeat Information Disclosure (Heartbleed)

Binary data scadatrianglegateway33729.nbin...

7.5CVSS7.3AI score0.99999EPSS
SaveExploits95References6
Rows per page
Query Builder