Lucene search

K
prionPRIOn knowledge basePRION:CVE-2023-2186
HistoryJun 07, 2023 - 7:15 a.m.

Format string

2023-06-0707:15:00
PRIOn knowledge base
www.prio-n.com
1
triangle microworks
scada data gateway
format string vulnerability
memory leakage
gtwwebmonitor.exe
code execution
dos
nvd

9.4 High

AI Score

Confidence

High

0.002 Low

EPSS

Percentile

55.7%

On Triangle MicroWorks’ SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.

CPENameOperatorVersion
scada_data_gatewayle5.01.03

9.4 High

AI Score

Confidence

High

0.002 Low

EPSS

Percentile

55.7%

Related for PRION:CVE-2023-2186