3061 matches found
CVE-2022-1667 Secheron SEPCOS Control and Protection Relay
Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC e.g., from the browser console or by loading the corresponding, browser accessible PHP script...
CVE-2022-1667 Secheron SEPCOS Control and Protection Relay
Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC e.g., from the browser console or by loading the corresponding, browser accessible PHP script...
CVE-2022-1667
CVE-2022-1667 affects Secheron SEPCOS Control and Protection Relay. Vulnerability: client-side JavaScript controls can be bypassed to reboot the PLC via browser console or browser-accessible PHP script, enabling an availability impact. Affects SEPCOS firmware prior to 1.23.21, 1.24.x prior to 1.2...
CVE-2022-32143
In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously...
Default credentials
In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously...
CVE-2022-32143 CODESYS runtime system prone to directory acces
In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously...
CVE-2022-32143
In CVE-2022-32143, multiple CODESYS products expose a file upload/download function that can access internal files in the working directory (e.g., PLC firmware). The issue is conditionally exploitable: requests are processed on the controller only if no level-1 password is configured or if the at...
CVE-2022-2003
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC...
CVE-2021-34606
A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and...
CVE-2021-34605
A zip slip vulnerability in XINJE XD/E Series PLC Program Tool up to version v3.5.1 can provide an attacker with arbitrary file write privilege when opening a specially-crafted project file. This vulnerability can be triggered by manually opening an infected project file, or by initiating an uplo...
CVE-2021-34606
A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and...
Information disclosure
A zip slip vulnerability in XINJE XD/E Series PLC Program Tool up to version v3.5.1 can provide an attacker with arbitrary file write privilege when opening a specially-crafted project file. This vulnerability can be triggered by manually opening an infected project file, or by initiating an uplo...
Design/Logic Flaw
A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and...
CVE-2021-34606 XINJE XD/E Series PLC Program Tool DLL Hijacking
A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and...
CVE-2021-34606
CVE-2021-34606 affects XINJE XD/E Series PLC Program Tool up to version 3.5.1. The issue is due to an Uncontrolled Search Path Element (DLL hijacking) that could allow an authenticated, local attacker with file-write privileges to place a malicious DLL and cause arbitrary code execution with the ...
CVE-2021-34605
CVE-2021-34605 affects XINJE XD/E Series PLC Program Tool up to version 3.5.1. A zip-slip flaw in handling a crafted project file could grant arbitrary file write, potentially enabling remote code execution, information disclosure and DoS on the tool. Affected path includes opening a malicious pr...
CVE-2021-34605 Xinje XD/E Series PLC Program Tool Zip Slip
A zip slip vulnerability in XINJE XD/E Series PLC Program Tool up to version v3.5.1 can provide an attacker with arbitrary file write privilege when opening a specially-crafted project file. This vulnerability can be triggered by manually opening an infected project file, or by initiating an uplo...
CVE-2021-34605
A zip slip vulnerability in XINJE XD/E Series PLC Program Tool up to version v3.5.1 can provide an attacker with arbitrary file write privilege when opening a specially-crafted project file. This vulnerability can be triggered by manually opening an infected project file, or by initiating an uplo...
CVE-2021-34606
A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and...
Design/Logic Flaw
Electric Vehicle EV commonly utilises the Combined Charging System CCS for DC rapid charging. To exchange important messages such as the State of Charge SoC with the Electric Vehicle Supply Equipment EVSE CCS uses a high-bandwidth IP link provided by the HomePlug Green PHY HPGP power-line...