3061 matches found
B&R Industrial Automation Automation Studio 4
1. EXECUTIVE SUMMARY CVSS v3 8.3 ATTENTION: Exploitable remotely Vendor: B&R Industrial Automation Equipment: Automation Studio 4 Vulnerability: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION An attacker could leverage this vulnerability to execute code within the context of...
plc-servo.jp Cross Site Scripting vulnerability OBB-2825230
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
CVE-2022-31207
The Omron SYSMAC Cx product family PLCs CS series, CJ series, and CP series through 2022-05-18 lack cryptographic authentication. They utilize the Omron FINS 9600/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. This protocol has authentication...
CVE-2022-31205
In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication...
CVE-2022-31205
In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication...
CVE-2022-29958
JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory...
CVE-2022-29951
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol configurable on ports 1024-65534 on either TCP or UDP for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing...
Authentication flaw
The Omron SYSMAC Cx product family PLCs CS series, CJ series, and CP series through 2022-05-18 lack cryptographic authentication. They utilize the Omron FINS 9600/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. This protocol has authentication...
CVE-2022-31207
The CVE-2022-31207 issue affects Omron SYSMAC CS/CJ/CP Series and NJ/NX Series PLCs (through 2022-05-18). The root cause is lack of cryptographic authentication for the FINS (9600/TCP) engineering protocol, allowing an attacker to manipulate downloaded object code that the PLC runs either in ASIC...
CVE-2022-31206
The Omron SYSMAC Nx product family PLCs NJ series, NY series, NX series, and PMAC series through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software which compiles IEC 61131-3 conformant POU code to native machine code for execution...
CVE-2022-31205
CVE-2022-31205 affects Omron SYSMAC CS/CJ/CP Series and NJ/NX Series PLCs (through 2022-05-18). The Web UI password is stored in memory (D1449...D1452) and can be read via the Omron FINS protocol without authentication, exposing the engineering password. Impact is user-level to potential configur...
CVE-2022-31206
CVE-2022-31206 affects Omron SYSMAC Nx product family PLCs (NJ/NY/NX/PMAC) prior to 2022-05-18. The issue is that the transferred PLC logic is not cryptographically authenticated, allowing an attacker to modify transmitted object code and execute arbitrary machine code on the PLC CPU module withi...
VulnCheck KEV: CVE-2022-2003
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect...
CVE-2022-1794
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...
Design/Logic Flaw
The CODESYS OPC DA Server prior V3.5.18.20 stores PLC passwords as plain text in its configuration file so that it is visible to all authorized Microsoft Windows users of the system...
Critical Security Flaws Identified in CODESYS ICS Automation Software
CODESYS has released patches to address as many as 11 security flaws that, if successfully exploited, could result in information disclosure and a denial-of-service DoS condition, among others. "These vulnerabilities are simple to exploit, and they can be successfully exploited to cause...
The vulnerability of the CMPLink/TCP protocol implementation in the microprogramming software for programmable logic controllers TOYOPUC allows a hacker to execute arbitrary code.
The vulnerability of the CMPLink/TCP protocol implementation in the microprogramming software for programmable logic controllers TOYOPUC is related to insufficient verification of data authenticity. Exploiting this vulnerability allows an attacker operating remotely to execute arbitrary code...
The vulnerability of microprogrammed software in programmable logic controllers SYSMAC NJ/NX, related to insufficient data authenticity checking, allows a intruder to execute arbitrary code.
The vulnerability of the microprogrammed software in SYSMAC NJ/NX programmable logic controllers is related to insufficient verification of data authenticity. Exploiting this vulnerability could allow an attacker operating remotely to execute arbitrary code...
CVE-2022-1667
Client-side JavaScript controls may be bypassed by directly running a JS function to reboot the PLC e.g., from the browser console or by loading the corresponding, browser accessible PHP script...
Design/Logic Flaw