3061 matches found
CVE-2021-32986 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without...
CVE-2021-32986 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without...
CVE-2021-32986
The CVE affects Automation Direct CLICK PLC CPU Modules (C0-1x CPUs) with firmware prior to v3.00. The vulnerability is an authentication bypass where, once an authorized user unlocks the PLC, the unlocked state does not timeout and remains usable if the programming software is interrupted; all s...
CVE-2021-32984 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...
CVE-2021-32984 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project...
CVE-2021-32984
CVE-2021-32984 affects Automation Direct CLICK PLC CPU Modules (C0-1x) with firmware prior to v3.00. Root cause: after an authorized unlock, all programming connections share unlocked privileges, enabling read/access to the project over the network. Impact: privilege escalation and unauthorized p...
CVE-2021-32978
The CVE-2021-32978 entry describes a vulnerability in Automation Direct CLICK PLC CPU Modules (C0-1x) with firmware prior to v3.00 where a previously entered password and lock state can be read from the programming protocol, effectively exposing credentials and enabling unlocks if the password wa...
CVE-2021-32978 Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...
CVE-2021-32978 Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00...
CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...
CVE-2021-32980
CVE-2021-32980 affects Automation Direct CLICK PLC CPU Modules, specifically the C0-1x CPUs with firmware older than 3.00. The issue is an authentication bypass via an alternate path or channel, caused by the firmware not protecting against additional software programming connections. An attacker...
CVE-2021-32980 Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active...
PT-2022-10178 · Automationdirect · Automation Direct Click Plc Cpu Modules
Name of the Vulnerable Software and Affected Versions: Automation Direct CLICK PLC CPU Modules: C0-1x CPUs versions prior to v3.00 Description: The issue arises when an authorized user unlocks the Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. The unlocked state...
Critical Bugs in Rockwell PLC Could Allow Hackers to Implant Malicious Code
Two new security vulnerabilities have been disclosed in Rockwell Automation's programmable logic controllers PLCs and engineering workstation software that could be exploited by an attacker to inject malicious code on affected systems and stealthily modify automation processes. The flaws have the...
Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37204)
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...
Siemens SIMATIC Industrial Products Missing Release of Memory After Effective Lifetime (CVE-2021-37205)
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...
Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37185)
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...
The vulnerability of the development environment “CX-Programmer,” which is part of the software suite “CX-One” designed for programming and configuring Omron PLCs, arises from reading data from within allowable buffer limits. This allows attackers to disclose sensitive information or execute arbitrary code.
The vulnerability of the development environment provided by CX-Programmer, which is part of the CX-One software suite designed for programming and configuring Omron PLCs, relates to the use of memory after it is freed. Exploiting this vulnerability can allow an attacker to disclose sensitive...
The vulnerability of the development environment “CX-Programmer,” which is part of the software suite “CX-One” designed for programming and configuring Omron PLCs, stems from the use of memory after it has been freed. This allows a malicious actor to execute arbitrary code.
The vulnerability of the development environment provided by CX-Programmer, which is part of the CX-One software suite designed for programming and configuring Omron PLCs, relates to the use of memory after it is freed. Exploiting this vulnerability can allow an attacker to execute arbitrary code...
Siemens S7-1200 - Unauthenticated Start / Stop Command Vulnerability
Exploit Title: Unauthenticated Siemens S7-1200 CPU Start/Stop Command Exploit Author: RoseSecurity Vendor Homepage: https://www.siemens.com/global/en.html Version: V4.5 and below Tested on: Siemens S7-1200 CPU: 1215C IP == PLC IP address Start Command curl -i -s -k -X $'POST' \ -H $'Host: ' -H...