CVE-2021-37162
Technical details for CVE-2021-37162 are not publicly available in the provided connected documents. Monitor for updates.
CVE-2021-37164
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...
CVE-2021-37164
The CVE-2021-37164 issue affects Swisslog Healthcare Nexus Control Panel (Nexus Panel). A stack-based buffer overflow is caused by an out-of-bounds write in tcpTxThread when processing received data, affecting released versions before Nexus Software 7.2.5.7. CNVD-2021-62178 confirms an out-of-bou...
CVE-2021-37163
CVE-2021-37163 affects Swisslog Healthcare Nexus HMI3 Control Panel (Nexus software before 7.2.5.7). The device has two hardcoded passwords and an insecure permissions issue, enabling potential unauthorized access over the network. Impact details are described as high/severe in the CVSS metrics. ...
CVE-2021-37163
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...
CVE-2021-37167
CVE-2021-37167 affects the HMI3 Control Panel in Swisslog Healthcare Nexus Panel, specifically released builds prior to Nexus Software 7.2.5.7. An insecure permissions issue allows a user who logs in with default credentials to gain root access to the device, granting full control over device fun...
CVE-2021-37167
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...
CVE-2021-37166
A buffer overflow issue leading to denial of service was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When HMI3 starts up, it binds a local service to a TCP port on all interfaces of the device, and...
CVE-2021-37166
CVE-2021-37166 affects Swisslog Healthcare Nexus Panel (HMI3 Control Panel). The issue is a buffer/connection handling vulnerability that occurs during startup when the HMI3 binds a local service to a TCP port on all interfaces and waits a long time for the GUI to connect, enabling an external at...
CVE-2021-37160
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...
CVE-2021-37160
CVE-2021-37160 impacts Swisslog Healthcare Nexus Panel firmware updates prior to Nexus Software 7.2.5.7, where there is no firmware validation (eg, cryptographic signature) during a firmware file upload. The vulnerability stems from missing validation during firmware update uploads, enabling pote...
CVE-2021-37161
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...
CVE-2021-37161
CVE-2021-37161 describes a buffer overflow in the Swisslog Healthcare Nexus Panel’s HMI3 Control Panel (pre Nexus Software 7.2.5.7) that can overwrite an internal queue data structure and lead to remote code execution. The impact is high (network, no auth, no user interaction). Remediation: upgra...
CVE-2021-37165
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...
CVE-2021-37165
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...
Buffer overflow
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...
CVE-2021-37165
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...
CVE-2021-37165
Technical details about CVE-2021-37165 are not publicly available in the provided Connected documents. The initial description notes a buffer overflow enabling remote code execution in Nexus Panel software prior to 7.2.5.7, but no confirmed exploit or remediation is documented here.
CVE-2021-37165
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead t...
Swisslog Healthcare Nexus Panel 缓冲区错误漏洞
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An out-of-bounds write vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to cause a stack buffer overflow...