CVE-2021-37152
CVE-2021-37152 affects Sonatype Nexus Repository Manager 3.x prior to 3.33.0. An authenticated attacker who can add HTML files to a repository could cause cross-site scripting by redirecting users to Nexus pages with modified code. Root cause: improper handling/delivery of HTML content uploaded t...
Sonatype Nexus Repository Manager 跨站脚本漏洞
Sonatype Nexus Repository Manager NXRM is a repository manager from Sonatype, Inc. that is used to manage, store, and distribute software, among other things. Sonatype Nexus Repository Manager suffers from a cross-site scripting vulnerability that stems from the ability to run JavaScript code in...
Nexus Control Panel Elevation of Privilege Vulnerability
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An elevation of privilege vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to gain root access to the device, which would allow access to all device...
Nexus Control Panel Buffer Overflow Vulnerability (CNVD-2021-62180)
Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability can be exploited to override the internal queue data structure, allowing for remote code execution...
Nexus Control Panel Buffer Overflow Vulnerability (CNVD-2021-62179)
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A buffer overflow vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. An attacker can exploit this vulnerability by sending a specially crafted message to the HMI to enable remote code execution...
Nexus Control Panel Licensing Issue Vulnerability
Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability stems from an improper method used to bind a local service to a port on the device interface. An attacker could use this...
Nexus Control Panel Buffer Overflow Vulnerability
Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, is vulnerable to an integer underflow vulnerability in versions prior to Nexus Control Panel 7.2.5.7. An attacker could use this vulnerability to override the internal queue data structure, which could enable remote code...
HMI3 Control Panel Trust Management Issue Vulnerability
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.A security vulnerability exists in the HMI3 Control Panel, which stems from an insecure privilege issue in the HMI3 Control Panel of the Swisslog Healthcare Nexus. No details of the vulnerability are currently available...
Nexus Control Panel Out-of-Bounds Writing Vulnerability
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An out-of-bounds write vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to cause a stack buffer overflow...
Nexus Control Panel Code Issue Vulnerability
Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A code download without integrity check vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. The vulnerability stems from no file validation during the upload of an update. No details of the...
Major Hospitals affected by PwnedPiper Vulnerabilities
THREAT LEVEL: White. For a detailed advisory, download the pdf file here. Multiple Zero-day vulnerabilities PwnedPiper have been found affecting the HMI-3 Control Panel of Swisslog Healthcare’s TransLogic Pneumatic Tube Systems PTS. PTS is a specialized system that uses compressor to transport...
Swisslog Healthcare Translogic PTS
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Swisslog Healthcare Equipment: Translogic PTS Pneumatic Tube Systems Vulnerabilities: Use of Hard-coded Password, Execution with Unnecessary Privileges, Improper Authentication, Download of Code without...
CVE-2021-37163
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...
CVE-2021-37164
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...
CVE-2021-37162
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...
CVE-2021-37163
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...
CVE-2021-37162
A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...
CVE-2021-37161
A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...
CVE-2021-37160
A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...
CVE-2021-37167
An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...