Lucene search
+L

5342 matches found

CVE
CVE
added 2021/08/10 1:25 p.m.58 views

CVE-2021-37152

CVE-2021-37152 affects Sonatype Nexus Repository Manager 3.x prior to 3.33.0. An authenticated attacker who can add HTML files to a repository could cause cross-site scripting by redirecting users to Nexus pages with modified code. Root cause: improper handling/delivery of HTML content uploaded t...

5.4CVSS5.1AI score0.24389EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
added 2021/08/09 12:0 a.m.6 views

Sonatype Nexus Repository Manager 跨站脚本漏洞

Sonatype Nexus Repository Manager NXRM is a repository manager from Sonatype, Inc. that is used to manage, store, and distribute software, among other things. Sonatype Nexus Repository Manager suffers from a cross-site scripting vulnerability that stems from the ability to run JavaScript code in...

5.4CVSS5.7AI score0.24389EPSS
SaveExploits0References4
CNVD
CNVD
added 2021/08/04 12:0 a.m.58 views

Nexus Control Panel Elevation of Privilege Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An elevation of privilege vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to gain root access to the device, which would allow access to all device...

10CVSS5.1AI score0.01737EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.33 views

Nexus Control Panel Buffer Overflow Vulnerability (CNVD-2021-62180)

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability can be exploited to override the internal queue data structure, allowing for remote code execution...

9.8CVSS5AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.25 views

Nexus Control Panel Buffer Overflow Vulnerability (CNVD-2021-62179)

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A buffer overflow vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. An attacker can exploit this vulnerability by sending a specially crafted message to the HMI to enable remote code execution...

9.8CVSS9.8AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.32 views

Nexus Control Panel Licensing Issue Vulnerability

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, has a security vulnerability in versions prior to Nexus Control Panel 7.2.5.7. The vulnerability stems from an improper method used to bind a local service to a port on the device interface. An attacker could use this...

7.8CVSS2.8AI score0.02062EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.54 views

Nexus Control Panel Buffer Overflow Vulnerability

Swisslog Healthcare Nexus Panel, a medical device from Swisslog Healthcare, is vulnerable to an integer underflow vulnerability in versions prior to Nexus Control Panel 7.2.5.7. An attacker could use this vulnerability to override the internal queue data structure, which could enable remote code...

9.8CVSS4.6AI score0.03264EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.80 views

HMI3 Control Panel Trust Management Issue Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.A security vulnerability exists in the HMI3 Control Panel, which stems from an insecure privilege issue in the HMI3 Control Panel of the Swisslog Healthcare Nexus. No details of the vulnerability are currently available...

7.5CVSS2.1AI score0.01439EPSS
SaveExploits0Affected Software1
CNVD
CNVD
added 2021/08/04 12:0 a.m.84 views

Nexus Control Panel Out-of-Bounds Writing Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare.An out-of-bounds write vulnerability exists in versions prior to Nexus Control Panel 7.2.5.7. An attacker could exploit this vulnerability to cause a stack buffer overflow...

9.8CVSS4AI score0.03396EPSS
SaveExploits0References1
CNVD
CNVD
added 2021/08/04 12:0 a.m.53 views

Nexus Control Panel Code Issue Vulnerability

Swisslog Healthcare Nexus Panel is a medical device from Swisslog Healthcare. A code download without integrity check vulnerability exists in Nexus Control Panel versions prior to 7.2.5.7. The vulnerability stems from no file validation during the upload of an update. No details of the...

9.8CVSS9.5AI score0.08227EPSS
SaveExploits0References1
hivepro
hivepro
added 2021/08/03 1:5 p.m.40 views

Major Hospitals affected by PwnedPiper Vulnerabilities

THREAT LEVEL: White. For a detailed advisory, download the pdf file here. Multiple Zero-day vulnerabilities PwnedPiper have been found affecting the HMI-3 Control Panel of Swisslog Healthcare’s TransLogic Pneumatic Tube Systems PTS. PTS is a specialized system that uses compressor to transport...

7.5CVSS9.8AI score0.03396EPSS
SaveExploits0
ICS
ICS
added 2021/08/03 12:0 a.m.63 views

Swisslog Healthcare Translogic PTS

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Swisslog Healthcare Equipment: Translogic PTS Pneumatic Tube Systems Vulnerabilities: Use of Hard-coded Password, Execution with Unnecessary Privileges, Improper Authentication, Download of Code without...

10CVSS10AI score0.08227EPSS
SaveExploits0References5
OSV
OSV
added 2021/08/02 1:15 p.m.4 views

CVE-2021-37163

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...

9.8CVSS7.5AI score0.03396EPSS
SaveExploits0References4
OSV
OSV
added 2021/08/02 1:15 p.m.5 views

CVE-2021-37164

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a...

9.8CVSS7.8AI score0.03396EPSS
SaveExploits0References4
OSV
OSV
added 2021/08/02 1:15 p.m.7 views

CVE-2021-37162

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

9.8CVSS7.8AI score0.03264EPSS
SaveExploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.32 views

CVE-2021-37163

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded...

9.8CVSS0.03396EPSS
SaveExploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.30 views

CVE-2021-37162

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote co...

9.8CVSS0.03396EPSS
SaveExploits0References4
OSV
OSV
added 2021/08/02 1:15 p.m.6 views

CVE-2021-37161

A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote...

9.8CVSS7.8AI score0.03396EPSS
SaveExploits0References4
NVD
NVD
added 2021/08/02 1:15 p.m.46 views

CVE-2021-37160

A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation e.g., cryptographic signature validation during a File Upload for a firmware update...

9.8CVSS0.08227EPSS
SaveExploits0References4
OSV
OSV
added 2021/08/02 1:15 p.m.4 views

CVE-2021-37167

An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. A user logged in using the default credentials can gain root access to the device, which provides permissions for all of t...

9.8CVSS7.3AI score0.01737EPSS
SaveExploits0References4
Rows per page
Query Builder