327 matches found
CVE-2020-7475
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...
CVE-2019-6855
Incorrect Authorization vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20 , and Modicon M580 all versions prior to V3.10, which could cause a bypass of the authentication process between...
Schneider Electric EcoStruxure Control Expert、EcoStruxure Process Expert和OPC Factory Server 输入验证错误漏洞
Schneider Electric EcoStruxure Control Expert formerly known as Unity Pro, among others, is a product of Schneider Electric, France.Schneider Electric EcoStruxure Control Expert is a suite of programming software for Schneider Electric logic controller products. Schneider Electric EcoStruxure...
CVE-2021-22797
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the...
CVE-2022-45789
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert All Versions, EcoStruxure Process Expert All Versions...
CVE-2022-45788
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert All...
Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408)
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. This plugin only works with Tenable.ot...
EcoStruxure Control Expert Unauthorized Access
The vulnerability of the programming interfaces for PLCs programmable logic controllers, namely EcoStruxure Control Expert and EcoStruxure Process Expert, lies in the use of strictly encrypted configuration data. Exploiting this vulnerability could allow an intruder to gain unauthorized access to...
EcoStruxure Control Expert Project File Access
The vulnerability of the programming tools for programmable logic controllers PLCs, EcoStruxure Control Expert and EcoStruxure Process Expert, is related to insufficient protection of registration data. Exploiting this vulnerability can allow an intruder to gain unauthorized access to the project...
CVE-2023-6409
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert...
CVE-2023-27975
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation...
CVE-2023-27975
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation...
Design/Logic Flaw
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation...
Hardcoded credentials
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert...
CVE-2023-27975
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation...
CVE-2023-27975
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation...
CVE-2023-27975
CVE-2023-27975 affects Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340/M580 PLCs. Root cause: CWE-522 Insufficiently Protected Credentials allowing a local user to tamper memory and gain unauthorized access to a project file; CVSS v3.1 base score 7.1 (H...
CVE-2023-6409
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert...
CVE-2023-6409
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert...
CVE-2023-6409: Use of Hard-coded Credentials