Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408)
| Reporter | Title | Published | Views | Family All 13 |
|---|---|---|---|---|
| The vulnerabilities of the microprogramming software for Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58*S, and M580 CPU Safety BMEH58*S, as well as the programming tools EcoStruxure Control Expert and EcoStruxure Process Expert, allow a attacker to execute a “man-in-the-middle” attack. | 13 Feb 202400:00 | – | bdu_fstec | |
| CVE-2023-6408 | 6 Mar 202417:16 | – | circl | |
| Schneider Electric Modicon M340 Security Breach | 14 Feb 202400:00 | – | cnnvd | |
| CVE-2023-6408 | 14 Feb 202416:52 | – | cve | |
| CVE-2023-6408 | 14 Feb 202416:52 | – | cvelist | |
| EUVD-2023-58645 | 3 Oct 202520:07 | – | euvd | |
| Vulnerabilities fixed in Scheider Electric EcoStruxture and Modicon | 15 Feb 202400:00 | – | ncsc | |
| CVE-2023-6408 | 14 Feb 202417:15 | – | nvd | |
| CVE-2023-6408 | 14 Feb 202417:15 | – | osv | |
| Design/Logic Flaw | 14 Feb 202417:15 | – | prion |
10
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(502835);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/02/25");
script_cve_id("CVE-2023-6408");
script_xref(name:"ICSA", value:"24-331-03");
script_name(english:"Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, and Modicon M340, M580 and M580 Safety PLCs Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2023-6408)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"CWE-924: Improper Enforcement of Message Integrity During Transmission
in a Communication Channel vulnerability exists that could cause a
denial of service and loss of confidentiality, integrity of
controllers when conducting a Man in the Middle attack.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
# https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?5e696d1f");
# https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?5e696d1f");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-24-331-03");
script_set_attribute(attribute:"solution", value:
'The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Schneider Electric has identified the following remediations and mitigations users can apply to reduce risk:
Modicon M340 CPU (part numbers BMXP34*):
- Firmware Version SV3.60 includes a fix for this vulnerability and is available for download.
- Set up an application password in the project properties.
- Set up network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP.
- Configure the access control list following the recommendations of the user manuals: "Modicon M340 for Ethernet
Communications Modules and Processors User Manual" in chapter "Messaging Configuration Parameters":
- Set up a secure communication according to the following guideline "Modicon Controllers Platform Cyber Security
Reference Manual," in chapter "Set up secured communications":
- Consider use of external firewall devices such as EAGLE40-07 from Belden to establish VPN connections for M340 & M580
architectures. For more details refer to the chapter "How to protect M580 and M340 architectures with EAGLE40 using VPN"
- Ensure the M340 CPU is running with the memory protection activated by configuring the input bit to a physical input,
for more details refer to the following guideline "Modicon Controllers Platform Cyber Security Reference Manual", "CPU
Memory Protection section".
Modicon M580 CPU (part numbers BMEP* and BMEH* excluding M580 CPU Safety):
- Firmware Versions SV4.20 includes a fix for this vulnerability and is available for download.
- Set up an application password in the project properties
- Setup network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP.
- Configure the access control list following the recommendations of the user manuals: "Modicon M580, Hardware,
Reference Manual".
- Set up a secure communication according to the following guideline "Modicon Controllers Platform Cyber Security
Reference Manual," in chapter "Set up secured communications":
- Use a BMENOC module and follow the instructions to configure IPSEC feature as described in the guideline "Modicon M580
- BMENOC03.1 Ethernet Communications Schneider Electric Security Notification Module, Installation and Configuration
Guide" in the chapter "Configuring IPSEC communications":
- Use a BMENUA0100 module and follow the instructions to configure IPSEC feature as described in the chapter
"Configuring the BMENUA0100 Cybersecurity Settings".
- Consider use of external firewall devices such as EAGLE40-07 from Belden to establish VPN connections for M340 & M580
architectures. For more details refer to the chapter "How to protect M580 and M340 architectures with EAGLE40 using
VPN".
- Ensure the M580 CPU is running with the memory protection activated by configuring the input bit to a physical input,
for more details refer to the following guideline "Modicon Controllers Platform Cyber Security Reference Manual", "CPU
Memory Protection section".
- The CPU memory protection cannot be configured with M580 Hot Standby CPUs. In such cases, use IPsec encrypted
communication .
Modicon M580 CPU Safety (part numbers BMEP58S and BMEH58S):
- Firmware SV4.21 includes a fix for CVE-2023-6408 and is available for download. Important: users needs to use version
of EcoStruxure Control Expert v16.0 HF001 minimum to connect with the latest version of M580 CPU Safety.
- If users choose not to apply the remediation, they are encouraged to immediately apply the following mitigations to
reduce the risk of exploit:
- Set up an application password in the project properties.
- Setup network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP.
- Configure the Access Control List following the recommendations of "Modicon M580, Hardware, Reference Manual"
- Set up a secure communication according to the following guideline "Modicon Controllers Platform Cyber Security
Reference Manual," in chapter "Set up secured communications".
- Use a BMENOC module and follow the instructions to configure IPSEC feature as described in the guideline "Modicon M580
- BMENOC03.1 Ethernet Communications Schneider Electric Security Notification Module, Installation and Configuration
Guide" in the chapter "Configuring IPSEC communications": https://www.se.com/ww/en/download/document/HRB62665/
- Use a BMENUA0100 module and follow the instructions to configure IPSEC feature as described in the chapter
"Configuring the BMENUA0100 Cybersecurity Settings"
- Consider use of external firewall devices such as EAGLE40-07 from Belden to establish VPN connections for M340 & M580
architectures. For more details refer to the chapter "How to protect M580 and M340 architectures with EAGLE40 using VPN"
- Ensure the M580 CPU is running with the memory protection activated by configuring the input bit to a physical input,
for more details refer to the following guideline "Modicon Controllers Platform Cyber Security Reference Manual", "CPU
Memory Protection section"
- NOTE: The CPU memory protection cannot be configured with M580 Hot Standby CPUs. In such cases, use IPsec encrypted
communication.
- To further reduce the attack surface on Modicon M580 CPU Safety: Ensure the CPU is running in Safety mode and
maintenance input is configured to maintain this Safety mode during operation â refer to the document Modicon M580 -
Safety System Planning Guide - in the chapter "Operating Mode Transitions".
- Schneider Electric is establishing a remediation plan for all future versions of EcoStruxure Process Expert that will
include a fix for CVE-2023-6409 and CVE-2023-27975. They will update SEVD-2024-317-04 when the remediation is available.
Until then, users should immediately apply the above mitigations to reduce the risk of exploit.
Modicon MC80 (part numbers BMKC80):
- Set up an application password in the project properties.
- Set up network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP.
- Configure the access control list following the recommendations of "Modicon MC80 Programmable Logic Controller (PLC)
manual" in the chapter "Access Control List (ACL)" a secure communication according to "Modicon Controller Systems
Cybersecurity, User Guide" in chapter "Set Up Encrypted Communication".
- (CVE-2023-6408) Schneider Electric Modicon Momentum Unity M1E Processor (171CBU*) All versions: Setup an application
password in the project properties
- Setup network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP
- Setup a secure communication according to the following guideline "Modicon Controller Systems Cybersecurity, User
Guide" in chapter "Set Up Encrypted Communication":
EcoStruxure Control Expert:
- Version 16.0 includes a fix for these vulnerabilities and is available for download. Reboot the computer after
installation is completed.
- Enable encryption on application project and store application files in secure location with restricted access only
for legitimate users.
- Schneider Electric recommends using McAfee Application and Change Control software for application control. Refer to
the Cybersecurity Application Note.
- Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices.
EcoStruxure Process Expert:
- Version 15.3 HF008 includes the fix for these vulnerabilities and is available for download.
- EcoStruxure Process Expert manages application files within its database in secure way. Do not export & store them
outside the application.
- Schneider Electric recommends using McAfee Application and Change Control software for application control. Refer to
the Cybersecurity Application Note.
- Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices.
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices and the associated
Schneider Electric Security Notification SEVD-2024-044-01 in PDF and CSAF.');
script_set_cvss_base_vector("CVSS2#AV:N/AC:H/Au:N/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-6408");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(924);
script_set_attribute(attribute:"vuln_publication_date", value:"2024/02/14");
script_set_attribute(attribute:"patch_publication_date", value:"2024/02/14");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/02/05");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/h:schneider-electric:modicon_mc80_bmkc8030311");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp341000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp341000h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp342000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp3420102_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp3420102cl_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp342010_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp342020_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp342020h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp3420302_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp3420302cl_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp3420302h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp342030_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_bmxp342030h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh582040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh582040c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh582040s_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh584040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh584040c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh584040s_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh586040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh586040c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmeh586040s_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep581020_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep581020h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep582020_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep582020h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep582040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep582040h_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep582040s_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep583020_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep583040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep584020_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep584040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep584040s_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep585040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep585040c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep586040_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_bmep586040c_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_mc80_bmkc8020301_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_mc80_bmkc8020310_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_momentum_171cbu78090_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_momentum_171cbu98090_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_momentum_171cbu98091_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:modicon_m340_bmxp341000_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp341000h_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp342000_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp342010_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp3420102_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp3420102cl_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp342020_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp342020h_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp342030_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp3420302_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp3420302cl_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp3420302h_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m340_bmxp342030h_firmware" :
{"versionEndExcluding" : "3.60", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m580_bmep581020_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep581020h_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep582020_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep582020h_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep582040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep582040h_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep582040s_firmware" :
{"versionEndExcluding" : "4.21", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep583020_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep583040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep584040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep584020_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep584040s_firmware" :
{"versionEndExcluding" : "4.21", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep585040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep585040c_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep586040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmep586040c_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh582040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh582040c_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh584040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh582040s_firmware" :
{"versionEndExcluding" : "4.21", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh584040c_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh584040s_firmware" :
{"versionEndExcluding" : "4.21", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh586040_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh586040c_firmware" :
{"versionEndExcluding" : "4.20", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_m580_bmeh586040s_firmware" :
{"versionEndExcluding" : "4.21", "family" : "ModiconM580"},
"cpe:/o:schneider-electric:modicon_mc80_bmkc8020301_firmware" :
{"family" : "ModiconMC80"},
"cpe:/o:schneider-electric:modicon_mc80_bmkc8020310_firmware" :
{"family" : "ModiconMC80"},
"cpe:/h:schneider-electric:modicon_mc80_bmkc8030311" :
{"family" : "ModiconMC80"},
"cpe:/o:schneider-electric:modicon_momentum_171cbu78090_firmware" :
{"family" : "MomentumUnity"},
"cpe:/o:schneider-electric:modicon_momentum_171cbu98090_firmware" :
{"family" : "MomentumUnity"},
"cpe:/o:schneider-electric:modicon_momentum_171cbu98091_firmware" :
{"family" : "MomentumUnity"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation
25 Feb 2025 00:00Current
7.2High risk
Vulners AI Score7.2
CVSS 3.18.1
EPSS0.00317
SSVC