CVE-2023-6409: Use of Hard-coded Credentials

CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert...

7.7CVSS5.8AI score0.0023EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2024/02/13 12:00 a.m.•25 views

PT-2024-2808 · Schneider Electric · Ecostruxure Process Expert +1

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert affected versions not specified EcoStruxure Process Expert affected versions not specified Description: A Use of Hard-coded Credentials issue exists that could cause unauthorized access to a project file protected...

7.7CVSS7.4AI score0.0023EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2024/02/13 12:00 a.m.•15 views

PT-2024-2809 · Schneider Electric · Ecostruxure Process Expert +1

Name of the Vulnerable Software and Affected Versions: EcoStruxure Control Expert affected versions not specified EcoStruxure Process Expert affected versions not specified Description: A vulnerability exists that could cause unauthorized access to the project file when a local user tampers with...

7.1CVSS6.6AI score0.00149EPSS
SaveExploits0References8
BDU FSTEC
BDU FSTEC
•added 2024/02/13 12:00 a.m.•22 views

Schneider Electric Modicon M340 CPU Man-in-the-Middle

The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, and M580 CPU Safety BMEH58S, as well as the PLC programming software EcoStruxure Control Expert and EcoStruxure Process...

8.1CVSS7.4AI score0.00317EPSS
SaveExploits0References2Affected Software4
Positive Technologies
Positive Technologies
•added 2024/02/13 12:00 a.m.•24 views

PT-2024-1606 · Schneider Electric · M580 Cpu Bmeh +4

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, M580 CPU Safety BMEH58S versions affected versions not specified EcoStruxure Control Expert versions affected versions not specified EcoStruxur...

8.1CVSS7.3AI score0.00317EPSS
SaveExploits0References7
BDU FSTEC
BDU FSTEC
•added 2023/07/04 12:00 a.m.•21 views

EcoStruxure Control Expert RemoteConnect Unauthenticated Access

The vulnerabilities of the PLC programming software EcoStruxure Control Expert, the automation system ProcessExpert, and the configuration software SCADAPack RemoteConnect are related to insufficient protection for registration data. Exploiting these vulnerabilities can allow attackers to gain...

5.5CVSS6AI score0.00109EPSS
SaveExploits0References2Affected Software1
BDU FSTEC
BDU FSTEC
•added 2023/06/28 12:00 a.m.•24 views

Modicon Logic Controller Malfunction

The vulnerability of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—is related to the...

7.8CVSS7.2AI score0.00937EPSS
SaveExploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
•added 2023/06/28 12:00 a.m.•20 views

Modicon Logic Controller Malfunction

The vulnerability of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—is related to reading...

6.8CVSS7.2AI score0.00839EPSS
SaveExploits0References3Affected Software2
BDU FSTEC
BDU FSTEC
•added 2023/06/28 12:00 a.m.•21 views

Modicon Logic Controller Malfunction

The vulnerability of microprogrammed logic controllers such as Modicon M580, Modicon M340, Modicon MC80, Modicon Momentum Ethernet, Modicon Quantum, Modicon Premium, and the programming software for these controllers—EcoStruxure Control Expert and EcoStruxure Process Expert—is related to the...

6.8CVSS7.3AI score0.00839EPSS
SaveExploits0References3Affected Software3
BDU FSTEC
BDU FSTEC
•added 2023/05/31 12:00 a.m.•20 views

EcoStruxure Control Exper Unauthorized Maintenance

The vulnerability of the EcoStruxure Control Exper programming tool for programmable logic controllers is related to deficiencies in the separation of the controlled system area. Exploiting this vulnerability could allow a malicious actor to perform a service failure remotely...

5.5CVSS5.9AI score0.00146EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
•added 2023/05/22 12:00 a.m.•23 views

EcoStruxure Control Expert Unauthorized Access SMTP

The vulnerability of the programming software for PLCs programmable logic controllers, as well as the EcoStruxure Process Expert automation system, is related to insufficient protection for registration data. Exploiting this vulnerability could allow attackers to gain unauthorized access to SMTP...

6.2CVSS5.9AI score0.00236EPSS
SaveExploits0References5Affected Software1
BDU FSTEC
BDU FSTEC
•added 2023/05/22 12:00 a.m.•24 views

Modicon PAC Controllers Maintenance Failure

The vulnerability of the microprogramming software of Modicon PAC controllers and PLCs included in EcoStruxure Control Expert and EcoStruxure Process Expert lies in the storage of data beyond the buffer boundaries. Exploiting this vulnerability could allow a malicious actor to trigger service...

6.8CVSS7.1AI score0.00839EPSS
SaveExploits0References3Affected Software3
BDU FSTEC
BDU FSTEC
•added 2023/05/04 12:00 a.m.•17 views

EcoStruxure Control Exper Code Execution

The vulnerability of the EcoStruxure Control Exper programming tool for programmable logic controllers is related to deficiencies in the separation of the controlled system area. Exploiting this vulnerability could allow a remote attacker to execute arbitrary code...

10CVSS8AI score0.00845EPSS
SaveExploits0References3
CNVD
CNVD
•added 2023/04/21 12:00 a.m.•48 views

Schneider Electric EcoStruxure Control Expert Denial of Service Vulnerability

Schneider Electric EcoStruxure Control Expert is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A denial of service vulnerability exists in Schneider Electric EcoStruxure Control Expert V15.1 and prior versions, which stems from...

5.5CVSS6.6AI score0.00146EPSS
SaveExploits0References1
CNVD
CNVD
•added 2023/04/21 12:00 a.m.•68 views

Schneider Electric EcoStruxure Control Expert Code Execution Vulnerability

Schneider Electric EcoStruxure Control Expert is a suite of programming software for Schneider Electric logic controller products from Schneider Electric, France. A code execution vulnerability exists in Schneider Electric EcoStruxure Control Expert V15.1 and prior versions, which arises from the...

8.8CVSS7.6AI score0.00845EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2023/04/18 5:15 p.m.•23 views

CVE-2023-1548

A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert V15.1 and above...

5.5CVSS6.1AI score0.00146EPSS
SaveExploits0References1
NVD
NVD
•added 2023/04/18 5:15 p.m.•28 views

CVE-2023-1548

A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert V15.1 and above...

5.5CVSS5.4AI score0.00146EPSS
SaveExploits0References1
NVD
NVD
•added 2023/04/18 5:15 p.m.•44 views

CVE-2023-27976

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert V15.1 and above...

8.8CVSS8.9AI score0.00845EPSS
SaveExploits0References1
Prion
Prion
•added 2023/04/18 5:15 p.m.•30 views

Remote code execution

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert V15.1 and above...

6.8CVSS8.8AI score0.00845EPSS
SaveExploits0References1Affected Software1
Prion
Prion
•added 2023/04/18 5:15 p.m.•31 views

Privilege escalation

A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert V15.1 and above...

1.7CVSS5.4AI score0.00146EPSS