Siemens SICAM GridEdge Authentication Error Vulnerability
SICAM GridEdge enables IoT functionality in your existing IEC 61850 devices with just a few clicks.Siemens SICAM GridEdge is vulnerable to an authentication error, which stems from the fact that the affected software does not require authenticated access to privileged functions and can be exploit...
CVE-2022-30937
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
CVE-2022-30937
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
Memory corruption
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant All versions, EN100 Ethernet module IEC 104 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO varia...
CVE-2022-30937
CVE-2022-30937 affects Siemens EN100 Ethernet Module variants: DNP3 IP, IEC 104, IEC 61850 (all versions prior to 4.37), Modbus TCP, and PROFINET IO. The issue is a memory corruption vulnerability in the HTTP parsing of the /txtrace endpoint, which could crash the affected application and cause a...
Siemens EN100 Ethernet Module
1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: EN100 Ethernet Module Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could...
PT-2022-5037 · Hitachi Energy · Hitachi Energy Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: Hitachi Energy MicroSCADA Pro SYS600 versions 9.4 FP2 Hotfix 4 and earlier Hitachi Energy MicroSCADA X SYS600 versions 10 through 10.3.1 Description: The issue is related to an Improper Input Validation vulnerability in the handling of a...
Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays Improper Input Validation (CVE-2018-16563)
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...
Hitachi Energy Relion 670, 650 and SAM600-IO Improper Input Validation (CVE-2021-27196)
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...
Siemens EN100 Ethernet Module Relative Path Traversal (CVE-2019-13944)
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
Siemens IEC 61850 System Configurator, DIGSI 5, DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, and SICAM SCC Improper Access Control (CVE-2018-4858)
A vulnerability has been identified in IEC 61850 system configurator All versions V5.80, DIGSI 5 affected as IEC 61850 system configurator is incorporated All versions V7.80, DIGSI 4 All versions V4.93, SICAM PAS/PQS All versions V8.11, SICAM PQ Analyzer All versions V3.11, SICAM SCC All versions...
ABB Relion 670 Series Improper Limitation of a Pathname to a Restricted Directory (CVE-2019-18253)
An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior outside the intended directory. This plugin only works with Tenable.ot. Please visit...
CVE-2021-27196
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...
Input validation
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...
CVE-2021-27196
CVE-2021-27196 affects Hitachi Energy Relion 670/650 series and related IEC 61850 interfaces. The issue is caused by improper input validation that allows an attacker with IEC 61850 network access to trigger a reboot, rendering affected devices inoperable for about 60 seconds. Affected products a...
CVE-2021-27196 Specially Crafted IEC 61850 Protocol Sequence Vulnerability
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...
Hitachi Energy Relion 670, 650 and SAM600-IO
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: Relion 670, 650, and SAM600-IO Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled...
CVE-2021-27196
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 TEGO1, MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce th...
Siemens En100 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
A vulnerability has been identified in EN100 Ethernet module DNP3 variant All versions, EN100 Ethernet module IEC 61850 variant All versions V4.37, EN100 Ethernet module IEC104 variant All versions, EN100 Ethernet module Modbus TCP variant All versions, EN100 Ethernet module PROFINET IO variant A...
CVE-2019-18267
An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site...