Lucene search
+L

149 matches found

CNNVD
CNNVD
added 2025/02/13 12:0 a.m.4 views

Schneider Electric Enerlin 输入验证错误漏洞

The Schneider Electric Enerlin is a series of communication devices from Schneider Electric France. The Schneider Electric Enerlin suffers from an input validation error vulnerability that stems from the inclusion of an improper input validation vulnerability that could cause a denial of service ...

6.9CVSS6.6AI score0.00369EPSS
Exploits0References1
CNNVD
CNNVD
added 2024/11/15 12:0 a.m.6 views

MZ Automation LibIEC61850 安全漏洞

Mz Automation Libiec61850 is an open source library for the IEC 61850 protocol from Mz Automation. A security vulnerability exists in MZ Automation LibIEC61850 that stems from the presence of multiple buffer overflows that allow a malicious server to cause a stack-based buffer overflow via an MMS...

9.8CVSS7.3AI score0.00597EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2024/11/06 12:0 a.m.7 views

The vulnerability of the mmsServerHandleDeleteNamedVariableListRequest() function in the C language library libIEC61850 allows a attacker to trigger a service failure.

The vulnerability of the mmsServerHandleDeleteNamedVariableListRequest function in the libIEC61850 library, written in the C language, is related to improper cleanup or release of resources. Exploiting this vulnerability could allow an attacker to cause service failures remotely...

7.8CVSS5.4AI score0.00785EPSS
Exploits1References5Affected Software1
NVD
NVD
added 2024/09/18 7:15 p.m.32 views

CVE-2024-34057

Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service...

8.2CVSS0.00444EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2024/09/18 12:0 a.m.16 views

CVE-2024-34057

Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service...

7.8AI score0.00444EPSS
Exploits0References2
Cvelist
Cvelist
added 2024/09/18 12:0 a.m.26 views

CVE-2024-34057

Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service...

0.00444EPSS
Exploits0References2
CVE
CVE
added 2024/09/18 12:0 a.m.53 views

CVE-2024-34057

CVE-2024-34057 affects Triangle Microworks TMW IEC 61850 Client libraries up to version 12.2.0, where a missing buffer size check during processing of MMS messages can overflow a buffer and cause a denial of service. Publicly documented impact notes reference Siemens SICAM/SITIPE product integrat...

8.2CVSS7.6AI score0.00444EPSS
Exploits0References2Affected Software1
CNVD
CNVD
added 2024/09/12 12:0 a.m.17 views

Siemens SICAM and SITIPE Products Third-Party Component Buffer Overflow Vulnerability

The SICAM 8 power automation platform is a universal, hardware and software based, all-in-one solution for all applications in the power sector. the SICAM A8000 RTUs Remote Terminal Units are modular devices for remote control and automation applications in all areas of energy supply. SICAM EGS...

8.2CVSS7.2AI score0.00444EPSS
Exploits0References1
ICS
ICS
added 2024/09/10 12:0 a.m.17 views

Siemens Third-Party Component in SICAM and SITIPE Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

8.2CVSS7AI score0.00444EPSS
Exploits0References10
Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.28 views

Hitachi Energy IEC 61850 MMS-Server Improper Resource Shutdown or Release (CVE-2022-3353)

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections...

7.5CVSS7.1AI score0.01105EPSS
Exploits0References12
Tenable Nessus
Tenable Nessus
added 2023/03/01 12:0 a.m.43 views

Siemens (CVE-2018-11452) (deprecated)

Plugin deprecated because en ethernetmodule is not detectable in this way This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. @DEPRECATED@ Disabled on 2023/05/15. Deprecated because en...

7.5AI score0.02389EPSS
Exploits0References4
F5 Networks
F5 Networks
added 2023/02/21 6:34 p.m.34 views

K45062506: Siemens Ethernet card DoS vulnerabilities CVE-2018-11451 and CVE-2018-11452

Security Advisory Description CVE-2018-11451 A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions,...

7.8CVSS7.4AI score0.02389EPSS
Exploits0
NVD
NVD
added 2023/02/21 2:15 p.m.31 views

CVE-2022-3353

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...

7.5CVSS6.4AI score0.01105EPSS
Exploits0References10
Prion
Prion
added 2023/02/21 2:15 p.m.20 views

Code injection

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...

5CVSS7.3AI score0.01105EPSS
Exploits0References10Affected Software13
Vulnrichment
Vulnrichment
added 2023/02/21 1:50 p.m.8 views

CVE-2022-3353 IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...

5.9CVSS7.4AI score0.01105EPSS
Exploits0References10
Cvelist
Cvelist
added 2023/02/21 1:50 p.m.31 views

CVE-2022-3353 IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products

A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client...

5.9CVSS7.6AI score0.01105EPSS
Exploits0References10
CVE
CVE
added 2023/02/21 1:50 p.m.60 views

CVE-2022-3353

CVE-2022-3353 affects Hitachi Energy devices operating the IEC 61850 MMS-Server across multiple product lines (FOX61x/TEGO1, GMS600, ITT600 SA Explorer, MICROSACDA X SYS600, MMS, PWC600, REB500, Relion 650/670/SAM600-IO, RTU500 CMU, TXpert Hub CoreTec 4/5, SYS600, and related variants). The vulne...

7.5CVSS6.4AI score0.01105EPSS
Exploits0References10Affected Software1
Positive Technologies
Positive Technologies
added 2023/02/21 12:0 a.m.7 views

PT-2023-13314 · Hitachi Energy · Hitachi Energy Products

Name of the Vulnerable Software and Affected Versions: Hitachi Energy products affected versions not specified fox61x tego1 versions r15b08 through r2a16 fox61x tego1 version r1e01 fox61x tego1 version r1d02 fox61x tego1 version r1c07 fox61x tego1 version r1b02 gms600 version 1.3.0 itt600 sa...

7.5CVSS7.3AI score0.01105EPSS
Exploits0References12
ICS
ICS
added 2023/02/14 1:30 p.m.43 views

Hitachi Energy IEC 61850 MMS-Server (Update B)

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: IEC 61850 MMS-Server Vulnerability: Improper Resource Shutdown or Release 2. RISK EVALUATION Successful exploitation of this vulnerability could cause products using the IEC 61850 MMS-server...

7.5CVSS7.3AI score0.01105EPSS
Exploits0References9
NVD
NVD
added 2022/10/11 9:15 p.m.29 views

CVE-2022-38138

The Triangle Microworks IEC 61850 Library Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C, or Java language library with a version number of 5.0.1 or earlier and 60870-6 ICCP/TASE.2 Library Any client or server...

7.5CVSS0.00764EPSS
Exploits0References1