Lucene search
+L

151 matches found

Exploit DB
Exploit DB
added 2019/05/16 12:00 a.m.147 views

SEL AcSELerator Architect 2.2.24 - CPU Exhaustion Denial of Service

!/usr/bin/env python coding: utf8 SEL AcSELerator Architect 2.2.24 Remote CPU Exhaustion Denial of Service Vendor: Schweitzer Engineering Laboratories, Inc. Product web page: https://www.selinc.com Affected version: 2.2.24.0 ICD package version: 2.38.0 Summary: Substation communications networks...

7.8CVSS7.5AI score0.07819EPSS
SaveExploits3
exploitpack
exploitpack
added 2019/05/16 12:00 a.m.49 views

SEL AcSELerator Architect 2.2.24 - CPU Exhaustion Denial of Service

SEL AcSELerator Architect 2.2.24 - CPU Exhaustion Denial of Service !/usr/bin/env python coding: utf8 SEL AcSELerator Architect 2.2.24 Remote CPU Exhaustion Denial of Service Vendor: Schweitzer Engineering Laboratories, Inc. Product web page: https://www.selinc.com Affected version: 2.2.24.0 ICD...

7.3AI score
SaveExploits0
zdt
zdt
added 2019/05/16 12:00 a.m.239 views

SEL AcSELerator Architect 2.2.24 - CPU Exhaustion Denial of Service Exploit

!/usr/bin/env python coding: utf8 SEL AcSELerator Architect 2.2.24 Remote CPU Exhaustion Denial of Service Vendor: Schweitzer Engineering Laboratories, Inc. Product web page: https://www.selinc.com Affected version: 2.2.24.0 ICD package version: 2.38.0 Summary: Substation communications networks...

7.5CVSS7.6AI score0.07819EPSS
SaveExploits3
NVD
NVD
added 2019/03/21 4:00 p.m.26 views

CVE-2018-16563

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...

5.9CVSS5.5AI score0.01155EPSS
SaveExploits0References1
CVE
CVE
added 2019/03/21 2:57 p.m.74 views

CVE-2018-16563

Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays are affected by CVE-2018-16563 due to improper input validation. Specially crafted packets sent to TCP port 102 can cause a denial-of-service, requiring a manual restart to restore EN100 module functionality. Exploitation requires ...

5.9CVSS5.5AI score0.01155EPSS
SaveExploits0References1Affected Software3
Positive Technologies
Positive Technologies
added 2019/01/23 12:00 a.m.11 views

PT-2019-18283 · Unknown +1 · Libiec61850 +1

Name of the Vulnerable Software and Affected Versions: libIEC61850 version 1.3.1 Description: The issue is related to a use-after-free in the getState function, located in the file mms/iso server/iso server.c. This is demonstrated by examples in server example goose.c and server example 61400 25....

10CVSS7.6AI score0.02036EPSS
SaveExploits9References35
ICS
ICS
added 2019/01/08 12:00 a.m.110 views

ICSA-19-038-02 Siemens EN100 Ethernet Module

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION : Exploitable remotely/low skill level to exploit Vendor : Siemens Equipment : EN100 Ethernet module Vulnerabilities : Improper Input Validation 2. RISK EVALUATION The EN100 Ethernet module for the SWT 3000 management platform is affected by security...

7.8CVSS8.1AI score0.02389EPSS
SaveExploits0References9
Prion
Prion
added 2018/07/23 9:29 p.m.24 views

Design/Logic Flaw

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.3AI score0.02389EPSS
SaveExploits0References3Affected Software3
NVD
NVD
added 2018/07/23 9:29 p.m.33 views

CVE-2018-11451

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.3AI score0.02389EPSS
SaveExploits0References3
NVD
NVD
added 2018/07/23 9:29 p.m.38 views

CVE-2018-11452

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.3AI score0.02389EPSS
SaveExploits0References3
Prion
Prion
added 2018/07/23 9:29 p.m.27 views

Design/Logic Flaw

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References3Affected Software3
CVE
CVE
added 2018/07/23 9:00 p.m.82 views

CVE-2018-11451

CVE-2018-11451 affects Siemens EN100 Ethernet Module and SIPROTEC 5 relays and is due to improper input validation. A specially crafted packet sent to port 102/tcp can cause a denial-of-service condition, affecting network availability. A manual restart is required to restore EN100 module functio...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References3Affected Software5
CVE
CVE
added 2018/07/23 9:00 p.m.78 views

CVE-2018-11452

CVE-2018-11452 affects Siemens EN100 Ethernet Module firmware variants (IEC 61850, PROFINET IO, Modbus TCP, DNP3 TCP, IEC104). The root cause is an improper handling of crafted packets to port 102/TCP that can trigger a Denial-of-Service condition when oscillographs are running, compromising avai...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References3Affected Software5
Cvelist
Cvelist
added 2018/07/23 9:00 p.m.38 views

CVE-2018-11451

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...

7.3AI score0.02389EPSS
SaveExploits0References3
ICS
ICS
added 2018/07/11 12:00 a.m.103 views

ICSA-18-347-02 Siemens EN100 Ethernet Communication Module and SIPROTEC 5 Relays (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: EN100 Ethernet Communication Module and SIPROTEC 5 relays Vulnerabilities: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original...

7.8CVSS8.2AI score0.02389EPSS
SaveExploits0References9
Prion
Prion
added 2018/07/09 7:29 p.m.24 views

Design/Logic Flaw

A vulnerability has been identified in IEC 61850 system configurator All versions V5.80, DIGSI 5 affected as IEC 61850 system configurator is incorporated All versions V7.80, DIGSI 4 All versions V4.93, SICAM PAS/PQS All versions V8.11, SICAM PQ Analyzer All versions V3.11, SICAM SCC All versions...

9.3CVSS7.6AI score0.01817EPSS
SaveExploits0References3Affected Software4
OSV
OSV
added 2018/07/09 7:29 p.m.12 views

CVE-2018-4858

A vulnerability has been identified in IEC 61850 system configurator All versions V5.80, DIGSI 5 affected as IEC 61850 system configurator is incorporated All versions V7.80, DIGSI 4 All versions V4.93, SICAM PAS/PQS All versions V8.11, SICAM PQ Analyzer All versions V3.11, SICAM SCC All versions...

7.8CVSS6.1AI score0.01817EPSS
SaveExploits0References3
CVE
CVE
added 2018/07/09 7:00 p.m.94 views

CVE-2018-4858

Siemens CVE-2018-4858 affects IEC 61850 system configurator family (IEC 61850 system configurator < v5.80; DIGSI 5 < v7.80; DIGSI 4 < v4.93; SICAM PAS/PQS < v8.11; SICAM PQ Analyzer < v3.11; SICAM SCC

9.3CVSS7.5AI score0.01817EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/07/09 7:00 p.m.38 views

CVE-2018-4858

A vulnerability has been identified in IEC 61850 system configurator All versions V5.80, DIGSI 5 affected as IEC 61850 system configurator is incorporated All versions V7.80, DIGSI 4 All versions V4.93, SICAM PAS/PQS All versions V8.11, SICAM PQ Analyzer All versions V3.11, SICAM SCC All versions...

7.5AI score0.01817EPSS
SaveExploits0References3
ICS
ICS
added 2018/06/26 12:00 a.m.617 views

ICSA-18-317-01 Siemens IEC 61850 System Configurator, DIGSI 5, DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, and SICAM SCC

1. EXECUTIVE SUMMARY CVSS v3 4.2 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: IEC 61850 system configurator, DIGSI 5, DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, and SICAM SCC Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability...

9.3CVSS7.8AI score0.01817EPSS
SaveExploits0References9
Rows per page
Query Builder