Lucene search
+L

456 matches found

Prion
Prion
•added 2021/10/12 10:15 a.m.•28 views

Design/Logic Flaw

A vulnerability has been identified in SINUMERIK 808D All versions, SINUMERIK 828D All versions V4.95. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device...

7.8CVSS7.3AI score0.01056EPSS
SaveExploits0References1Affected Software1
attackerkb
attackerkb
•added 2021/10/12 10:15 a.m.•12 views

CVE-2021-37199

A vulnerability has been identified in SINUMERIK 808D All versions, SINUMERIK 828D All versions V4.95. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device...

7.8CVSS6.9AI score0.01056EPSS
SaveExploits0References2
CVE
CVE
•added 2021/10/12 9:49 a.m.•72 views

CVE-2021-37199

CVE-2021-37199 affects Siemens SINUMERIK 808D (all versions) and SINUMERIK 828D (all versions

7.8CVSS7.3AI score0.01056EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2021/10/12 12:00 a.m.•6 views

PT-2021-21570

Name of the Vulnerable Software and Affected Versions SINUMERIK 808D All versions SINUMERIK 828D versions prior to V4.95 Description A vulnerability has been identified where affected devices do not process certain specially crafted packets sent to port 102/tcp correctly. This could allow an...

7.8CVSS0.01056EPSS
SaveExploits0References4
CNNVD
CNNVD
•added 2021/10/12 12:00 a.m.•21 views

Siemens Sinumerik 808D 缓冲区错误漏洞

SINUMERIK CNCs provide automation solutions for shop floor, workshop and large volume production environments. a denial of service vulnerability exists in Siemens SINUMERIK Controllers. the vulnerability stems from the fact that the affected device fails to properly handle certain specially craft...

7.8CVSS5.6AI score0.01056EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/10/12 12:00 a.m.•9 views

CVE-2021-37199: Heap-based Buffer Overflow

A vulnerability has been identified in SINUMERIK 808D All versions, SINUMERIK 828D All versions V4.95. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device...

7.8CVSS5.7AI score0.01056EPSS
SaveExploits0References3
CNVD
CNVD
•added 2021/09/15 12:00 a.m.•76 views

Siemens SIMATIC NET CP Module Denial of Service Vulnerability

The Communication Processor CP modules of the SIMATIC CP 343-1 and CP 443-1 series are designed to support the SIMATIC S7-300/S7-400 CPUs for Ethernet communication.The SIPLUS Extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP,...

7.8CVSS7.4AI score0.01056EPSS
SaveExploits0References1
attackerkb
attackerkb
•added 2021/09/14 11:15 a.m.•13 views

CVE-2021-33737

A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 343-1 ERPC All versions, SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP...

7.8CVSS6.9AI score0.01056EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/09/14 12:00 a.m.•7 views

CVE-2021-33737: Improper Restriction of Operations within the Bounds of a Memory Buffer

A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 343-1 ERPC All versions, SIMATIC CP 343-1 Lean incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP...

7.8CVSS5.6AI score0.01056EPSS
SaveExploits0References2
ICS
ICS
•added 2021/09/14 12:00 a.m.•99 views

Siemens SIMATIC NET CP Modules

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...

7.8CVSS7.7AI score0.01056EPSS
SaveExploits0References12
CNNVD
CNNVD
•added 2021/09/14 12:00 a.m.•21 views

Siemens SIAMTIC CP343-1 缓冲区错误漏洞

The Communication Processor CP modules of the SIMATIC CP 343-1 and CP 443-1 series are designed to support the SIMATIC S7-300/S7-400 CPUs for Ethernet communication.The SIPLUS Extreme products are designed for reliable operation under extreme conditions and are based on SIMATIC, LOGO!, SITOP,...

7.8CVSS5.6AI score0.01056EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
•added 2021/09/01 12:00 a.m.•12 views

PT-2021-7270 · Siemens · Simatic S7-400 Cpu 416-3 Pn/Dp V7 +13

Name of the Vulnerable Software and Affected Versions: SIMATIC S7-400 CPU 412-1 DP V7 versions prior to V7.0.3 SIMATIC S7-400 CPU 412-2 DP V7 versions prior to V7.0.3 SIMATIC S7-400 CPU 412-2 PN/DP V7 versions prior to V7.0.3 SIMATIC S7-400 CPU 414-2 DP V7 versions prior to V7.0.3 SIMATIC S7-400...

7.8CVSS7.3AI score0.01004EPSS
SaveExploits0References4
CNVD
CNVD
•added 2021/08/11 12:00 a.m.•58 views

Siemens SIMATIC S7-1500 CPU and SIMATIC S7-1500 Incorrect Authorization Vulnerability

The Siemens SIMATIC S7-1500 CPU and SIMATIC S7-1500 are both products of Siemens, Germany.The SIMATIC S7-1500 CPU is a CPU central processing unit module.The SIMATIC S7-1500 is a programmable logic controller. A security vulnerability exists in the Siemens SIMATIC S7-1500 CPU and SIMATIC S7-1500...

5.3CVSS5.1AI score0.00752EPSS
SaveExploits0References1
NVD
NVD
•added 2021/08/10 11:15 a.m.•34 views

CVE-2020-28397

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2 V2.5 V2.5 V21.9, TIM 1531 IRC incl. SIPLUS NET variants Version V2.1. Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program...

5.3CVSS0.00752EPSS
SaveExploits0References1
Prion
Prion
•added 2021/08/10 11:15 a.m.•36 views

Authorization

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2 V2.5 V2.5 V21.9, TIM 1531 IRC incl. SIPLUS NET variants Version V2.1. Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program...

5CVSS5AI score0.00752EPSS
SaveExploits0References1Affected Software56
CVE
CVE
•added 2021/08/10 10:35 a.m.•204 views

CVE-2020-28397

CVE-2020-28397 affects Siemens SIMATIC products due to an incorrect authorization check that could allow an attacker to read information about access-protected PLC variables via port 102/tcp when multiple attributes are read. Affected: SIMATIC Drive Controller family (all versions < V2.9.2); S...

5.3CVSS5AI score0.00752EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2021/08/10 12:00 a.m.•8 views

PT-2021-11517

Name of the Vulnerable Software and Affected Versions: SIMATIC Drive Controller family versions prior to V2.9.2 SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants versions prior to V21.9 SIMATIC S7 PLCSIM Advanced versions prior to V4 SIMATIC S7-1200 CPU family incl. SIPLUS...

5.3CVSS5.5AI score0.00752EPSS
SaveExploits0References4
NVD
NVD
•added 2021/05/28 4:15 p.m.•31 views

CVE-2020-15782

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2.9.2, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V21.9, SIMATIC S7-1200 CPU family incl...

9.8CVSS0.05184EPSS
SaveExploits0References3
osv_cve
osv_cve
•added 2021/05/28 4:15 p.m.•20 views

CVE-2020-15782

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2.9.2, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V21.9, SIMATIC S7-1200 CPU family incl...

9.8CVSS5.9AI score0.05184EPSS
SaveExploits0References3
Prion
Prion
•added 2021/05/28 4:15 p.m.•30 views

Memory corruption

A vulnerability has been identified in SIMATIC Drive Controller family All versions V2.9.2, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V21.9, SIMATIC S7-1200 CPU family incl...

7.5CVSS9.6AI score0.05184EPSS
SaveExploits0References3Affected Software4
Rows per page
Query Builder