Lucene search
+L

392 matches found

zdt
zdt
added 2020/02/06 12:00 a.m.205 views

Cisco Data Center Network Manager 11.2.1 - (LanFabricImpl) Command Injection Exploit

Exploit for java platform in category web applications !/usr/bin/python """ Cisco Data Center Network Manager LanFabricImpl createLanFabric Command Injection Remote Code Execution Vulnerability Tested on: Cisco DCNM 11.2.1 ISO Virtual Appliance for VMWare, KVM and Bare-metal servers - Release:...

9CVSS7.3AI score0.3811EPSS
SaveExploits6
Prion
Prion
added 2019/12/11 10:15 p.m.16 views

Information disclosure

SAP Portfolio and Project Management, before versions S4CORE 102, 103, EPPM 100 and CPRXRPM 500702, 600740, 610740; unintentionally allows a user to discover accounting information of the Projects in Project dashboard, leading to Information Disclosure...

4CVSS6.3AI score0.00882EPSS
SaveExploits0References2Affected Software1
ICS
ICS
added 2019/12/10 12:00 a.m.95 views

Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)

1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC S7-1200 and S7-1500 CPU families Vulnerabilities: Use of a Broken or Risky Cryptographic Algorithm, Missing Support for Integrity Check 2. UPDATE INFORMATION This updated...

7.5CVSS6.7AI score0.00978EPSS
SaveExploits0References5
ICS
ICS
added 2019/12/10 12:00 a.m.112 views

Siemens SIMATIC Products (Update C)

1. EXECUTIVE SUMMARY CVSS v3 3.7 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SIMATIC CP 1626; HMI Panel incl. SIPLUS variants; NET PC software; STEP 7 TIA Portal; WinCC TIA Portal; WinCC OA; WinCC Runtime Pro and Advanced; TIM 1531 IRC incl. SIPLUS variant Vulnerability: Exposed...

5.9CVSS5.9AI score0.00978EPSS
SaveExploits0References11
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.24 views

Siemens Simatic Uncontrolled Resource Consumption

A vulnerability has been identified in SIMATIC S7-1200 All versions, SIMATIC S7-1500 All Versions V2.6. An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be abl...

5CVSS3.6AI score0.01799EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.26 views

Siemens Simatic Improper Input Validation

A vulnerability has been identified in SIMATIC S7-400 incl. F V6 and below All versions, SIMATIC S7-400 PN/DP V7 incl. F All versions, SIMATIC S7-400H V4.5 and below All versions, SIMATIC S7-400H V6 All versions V6.0.9, SIMATIC S7-410 All versions V8.2.1. Specially crafted packets sent to port...

7.8CVSS3.8AI score0.01545EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.22 views

Siemens Simatic Exposure of Sensitive Information to an Unauthorized Actor

A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...

4.3CVSS2.5AI score0.01538EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.28 views

Siemens Simatic Improper Access Control

A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions = 20.8, SIMATIC ET200SP incl. SIPLUS variants Open Controller CPU 1515SP PC All versions,...

5CVSS1.9AI score0.00952EPSS
SaveExploits0References2
CNVD
CNVD
added 2019/08/14 12:00 a.m.11 views

SIMATICS7-1200 and SIMATICS7-1500CPU families Man-in-the-Middle Attack Vulnerability

The Simatic S7-1200 CPU and Simatic S7-1500 CPU families are used for discrete and continuous control in industrial environments, such as manufacturing, food and beverage, and the chemical industry. A man-in-the-middle attack vulnerability exists in the SIMATICS7-1200 and SIMATICS7-1500 CPU...

5.9CVSS6.8AI score0.00978EPSS
SaveExploits0References1
OSV
OSV
added 2019/08/13 7:15 p.m.10 views

CVE-2019-10929

A vulnerability has been identified in SIMATIC CP 1626 All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V20.8, SIMATIC HMI Panel incl. SIPLUS variants All versions,...

5.9CVSS6.2AI score0.00978EPSS
SaveExploits0References3
NVD
NVD
added 2019/08/13 7:15 p.m.57 views

CVE-2019-10929

A vulnerability has been identified in SIMATIC CP 1626 All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V20.8, SIMATIC HMI Panel incl. SIPLUS variants All versions,...

5.9CVSS5.9AI score0.00978EPSS
SaveExploits0References3
Prion
Prion
added 2019/08/13 7:15 p.m.23 views

Design/Logic Flaw

A vulnerability has been identified in SIMATIC CP 1626 All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V20.8, SIMATIC HMI Panel incl. SIPLUS variants All versions,...

4.3CVSS5.8AI score0.00978EPSS
SaveExploits0References3Affected Software10
CVE
CVE
added 2019/08/13 6:55 p.m.99 views

CVE-2019-10929

CVE-2019-10929 affects Siemens SIMATIC products (S7-1200/1500 families, ET200SP Open Controllers, HMI/WinCC/STEP 7, TIM 1531 IRC, etc.). The flaw is a message protection bypass caused by properties in the integrity-protection calculation, enabling a man-in-the-middle attacker with network access ...

5.9CVSS5.5AI score0.00978EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2019/08/13 6:55 p.m.54 views

CVE-2019-10929

A vulnerability has been identified in SIMATIC CP 1626 All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions V20.8, SIMATIC HMI Panel incl. SIPLUS variants All versions,...

5.6AI score0.00978EPSS
SaveExploits0References3
NVD
NVD
added 2019/08/01 5:15 p.m.16 views

CVE-2016-10832

cPanel before 55.9999.141 allows FTP cPHulk bypass via account name munging SEC-102...

6.5CVSS6.6AI score0.00985EPSS
SaveExploits0References1
CVE
CVE
added 2019/08/01 4:12 p.m.55 views

CVE-2016-10832

CVE-2016-10832 affects cPanel prior to 55.9999.141. The vulnerability is an FTP cPHulk bypass via account name munging (SEC-102), enabling bypass of FTP authentication checks. Root cause: improper handling during the cPHulk workflow allows bypass when munging the account name. Impact: potential u...

6.5CVSS6.5AI score0.00985EPSS
SaveExploits0References1Affected Software1
OSV
OSV
added 2019/03/21 4:00 p.m.5 views

CVE-2018-16563

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.35, Firmware variant MODBUS TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet module All versions, Firmware variant IEC104 for EN100 Ethernet module A...

5.9CVSS5.7AI score0.01155EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
added 2019/03/12 12:00 a.m.13 views

The vulnerability of microprogrammed software in Siemens Simatic S7-400 programmable logic controllers is related to errors in checking input data by Ethernet, PROFIBUS, and MPI interfaces. This allows a malicious actor to trigger a service failure.

The vulnerability of microprogrammed programmable logic controllers from Siemens Simatic S7-400 is related to errors in the validation of input data by Ethernet, PROFIBUS, and MPI interfaces. Exploiting this vulnerability can allow an attacker to cause malfunctions in the system by sending a...

7.8CVSS7.2AI score0.01545EPSS
SaveExploits0References3Affected Software4
BDU FSTEC
BDU FSTEC
added 2019/03/06 12:00 a.m.12 views

The vulnerability of Siemens’ communication module software, related to insufficient validation of input data, allows a perpetrator to trigger a service failure of the module.

The vulnerability of Siemens’ communication module’s microprogramming software is related to insufficient verification of input data. Exploiting this vulnerability can allow attackers to cause malfunctions in the module by sending specially crafted packets to port 102/TCP...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References4Affected Software1
BDU FSTEC
BDU FSTEC
added 2019/03/06 12:00 a.m.13 views

The vulnerability of Siemens’ communication module software, related to insufficient validation of input data, allows a perpetrator to trigger a service failure of the module.

The vulnerability of Siemens’ communication module’s microprogramming software is related to insufficient verification of input data. Exploiting this vulnerability can allow attackers to cause malfunctions in the module by sending specially crafted packets to port 102/TCP...

7.8CVSS7.2AI score0.02389EPSS
SaveExploits0References4Affected Software1
Rows per page
Query Builder