392 matches found
PT-2022-2054 · Siemens · Simatic S7-1500 Software Controller +7
Name of the Vulnerable Software and Affected Versions: SIMATIC Drive Controller family versions 2.9.2 through 2.9.4 SIMATIC ET 200SP Open Controller CPU 1515SP PC2 versions 21.9 through 21.9.4 SIMATIC S7-1200 CPU family versions 4.5.0 through 4.5.2 SIMATIC S7-1500 CPU family versions 2.9.2 throug...
PT-2022-1965 · Siemens · Simatic Et 200Sp Open Controller Cpu 1515Sp Pc2 Ready4Linux +9
Name of the Vulnerable Software and Affected Versions: SIMATIC Drive Controller family versions prior to V2.9.2 SIMATIC Drive Controller family versions V2.9.2 through V2.9.4 SIMATIC ET 200SP Open Controller CPU 1515SP PC versions prior to V21.9 SIMATIC ET 200SP Open Controller CPU 1515SP PC2...
Siemens SIMATIC Industrial Products (Update A)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
PT-2022-1966 · Siemens · Simatic S7-1500 Software Controller +7
Name of the Vulnerable Software and Affected Versions: SIMATIC Drive Controller family versions 2.9.2 through 2.9.4 SIMATIC ET 200SP Open Controller CPU 1515SP PC2 versions 21.9 through 21.9.4 SIMATIC S7-1200 CPU family versions 4.5.0 through 4.5.2 SIMATIC S7-1500 CPU family versions 2.9.2 throug...
Siemens S7-300/400 PLC (CVE-2016-9159)
A vulnerability has been identified in SIMATIC S7-300 CPU family All versions, SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC S7-400 PN/DP V6 and below CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP V7 CPU family incl. SIPLUS...
Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2018-13815)
A vulnerability has been identified in SIMATIC S7-1200 All versions, SIMATIC S7-1500 All Versions V2.6. An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be abl...
Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller Uncontrolled Resource Consumption (CVE-2020-15783)
A vulnerability has been identified in SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC TDC CPU555 All versions, SINUMERIK 840D sl All versions. Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port...
Siemens SIMATIC S7-1500 Protection Mechanism Failure (CVE-2016-2201)
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network...
Siemens SIMATIC S7-1200 and S7-1500 CPU Families Missing Support For Integrity Check (CVE-2019-10943)
An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the...
Siemens SIMATIC S7-1200 CPU Family Denial of Service (CVE-2013-0700)
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service defect-mode transition and control outage via crafted packets to TCP port 102 aka the ISO-TSAP port. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for mo...
Siemens SIMATIC Products Use of a Broken or Risky Cryptographic Algorithm (CVE-2019-10929)
Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices. This plugin only work...
Siemens SIMATIC S7-1500 Improper Input Validation (CVE-2016-2200)
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service STOP mode transition via crafted packets on TCP port 102. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300...
ABB Relion 670 Series Improper Limitation of a Pathname to a Restricted Directory (CVE-2019-18253)
An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior outside the intended directory. This plugin only works with Tenable.ot. Please visit...
Microsoft Patch Tuesday for Jan. 2022 — Snort rules and prominent vulnerabilities
By Jon Munshaw and Vitor Ventura. Microsoft released its monthly security update Tuesday, disclosing 102 vulnerabilities across its large collection of hardware and software. This is the largest amount of vulnerabilities Microsoft has disclosed in a monthly security update in eight months,... Thi...
Mozilla Firefox Security Advisory (MFSA2012-102) - Linux
This host is missing a security update for Mozilla Firefox. Copyright C 2021 Greenbone Networks GmbH Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later This program is free software; y...
Siemens SINUMERIK Controllers Denial of Service Vulnerability
SINUMERIK CNCs provide automation solutions for shop floor, workshop and large volume production environments. a denial of service vulnerability exists in Siemens SINUMERIK Controllers. the vulnerability stems from the fact that the affected device fails to properly handle certain specially craft...
CVE-2021-37199
A vulnerability has been identified in SINUMERIK 808D All versions, SINUMERIK 828D All versions V4.95. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device...
Design/Logic Flaw
A vulnerability has been identified in SINUMERIK 808D All versions, SINUMERIK 828D All versions V4.95. Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device...
CVE-2021-37199
CVE-2021-37199 affects Siemens SINUMERIK 808D (all versions) and SINUMERIK 828D (all versions
Siemens Sinumerik 808D 缓冲区错误漏洞
SINUMERIK CNCs provide automation solutions for shop floor, workshop and large volume production environments. a denial of service vulnerability exists in Siemens SINUMERIK Controllers. the vulnerability stems from the fact that the affected device fails to properly handle certain specially craft...