1688 matches found
CISA Releases Nine Industrial Control Systems Advisories
CISA released nine Industrial Control Systems ICS advisories on February 4, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-035-01 Western Telematic Inc NPS Series, DSM Series, CPM Series ICSA-25-035-02 Rockwe...
The vulnerability of the microprogrammed software used in Modicon M580 programmable logic controllers and the EVLink Pro AC charging stations relates to incorrect calculations of the size of the allocated buffer. This vulnerability allows a intruder to cause malfunctions in the equipment.
The vulnerability of the microprogrammed software used in Modicon M580 programmable logic controllers and the EVLink Pro AC charging stations is related to incorrect calculations of the size of the buffer space allocated. Exploiting this vulnerability allows a malicious actor to cause service...
Schneider Electric Modicon M340 信息泄露漏洞
The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric France. An information disclosure vulnerability exists in the Schneider Electric Modicon M340, which stems from the inclusion of an Exposure of...
Schneider Electric Modicon M580 安全漏洞
The Schneider Electric Modicon M580 is a programmable automation controller from Schneider Electric France. A security vulnerability exists in the Schneider Electric Modicon M580 that stems from the inclusion of a buffer size miscalculation vulnerability that could result in a denial of service o...
Vulnerabilities fixed in Schneider Electric Modicon
Schneider Electric has fixed vulnerabilities in Modicon M340, M580 and various communication modules. A malicious party could exploit the vulnerabilities to cause a denial-of-service or gain access to system data and possibly affect the operation of the controllers. For successful abuse, the...
Schneider Electric EcoStruxure Power Monitoring Expert (PME) (Update A)
RISK EVALUATION Successful exploitation of this vulnerability could cause a denial-of-service of the product when an unauthenticated user sends a crafted HTTPS packet to the webserver. 2. RECOMMENDED PRACTICES CISA reminds organizations to perform proper impact analysis and risk assessment prior...
Schneider Electric Modicon M340 and BMXNOE0100/0110, BMXNOR0200H (Update B)
RISK EVALUATION Successful exploitation of this vulnerability could cause information disclosure of a restricted web page, modification of a web page and a denial of service when specific web pages are modified and restricted functions are invoked. 2. RECOMMENDED PRACTICES CISA reminds...
Schneider Electric Modicon Improper Input Validation (CVE-2024-11737)
An improper input validation vulnerability exists that could lead to a denial-of-service and a loss of confidentiality and integrity in the controller when an unauthenticated crafted Modbus packet is sent to the device. This plugin only works with Tenable.ot. Please visit...
Vulnerability fixed in Schneider Electric Modicon
Schneider Electric has fixed a vulnerability in devices that use the Modbus protocol. The vulnerability is in how devices using the Modbus protocol validate input. When an unauthenticated and customized Modbus packet is sent to the device, it can result in a denial-of-service, compromising both t...
Schneider Electric Modicon Controllers 输入验证错误漏洞
Schneider Electric Modicon Controllers is a Modicon family of programmable logic controllers from Schneider Electric France. An input validation error vulnerability exists in Schneider Electric Modicon Controllers that stems from incorrect input validation. When unauthenticated specially crafted...
The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers allows a perpetrator to carry out a “man-in-the-middle” attack.
The vulnerability of the Modbus protocol implementation in Schneider Electric Modicon M340 CPU BMXP34 programmable logic controllers is related to insufficient verification of input data. Exploiting this vulnerability can allow an attacker to carry out a “man-in-the-middle” attack remotely...
The vulnerability of the Diffie-Hellman algorithm in microprogrammed logic controllers (PLCs) from Schneider Electric Modicon M340 CPU BMXP34 allows a attacker to execute a “man-in-the-middle” attack.
The vulnerability of the Diffie-Hellman algorithm in microprogrammed logic controllers PLCs from Schneider Electric Modicon M340 CPU BMXP34 lies in the ability to bypass authentication through spoofing. Exploiting this vulnerability allows a malicious actor to carry out a “man-in-the-middle” atta...
The vulnerability of microprogrammed software for Schneider Electric Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the lack of checks for the integrity of messages during transmission over communication channels. This allows attackers to disclose sensitive information or cause malfunctions in the system.
The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, stems from the lack of checks for the integrity of messages during transmission over communication...
The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers (PLCs), such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, allows a attacker to execute a “man-in-the-middle” attack.
The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers PLCs such as Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the execution of operations outside the buffer in memory. Exploiting th...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Input Validation (CVE-2024-8936)
An Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory. This plugin only works with Tenable.ot. Please visit...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Enforcement of Message Integrity During Transmission in a Communication Channel (CVE-2024-8933)
A vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themselves inside the logical network while a valid user uploads or downloads a project...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Authentication Bypass By Spoofing (CVE-2024-8935)
A vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is...
Schneider Electric Modicon M340, MC80, and Momentum Unity M1E Improper Restriction of Operations Within the Bounds of a Memory Buffer (CVE-2024-8938)
Arbitrary code execution can potentially be achieved after a successful Man-In-The Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation. This plugin only works with Tenable.ot. Please visit...
The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers (PLCs), such as the Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU, allows a attacker to execute a “man-in-the-middle” attack.
The vulnerability of the Modbus protocol implementation in Schneider Electric’s programmable logic controllers PLCs such as Modicon M340 CPU BMXP34, Modicon MC80 BMKC80, and Modicon Momentum Unity M1E Processor 171CBU lies in the execution of operations outside the buffer in memory. Exploiting th...
Schneider Electric Modicon M340 输入验证错误漏洞
The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. An input validation error vulnerability exists in the Schneider Electric Modicon M340, which stems from the presence of an improper inpu...