added 2024/04/11 12:0 a.m.15 views

Schneider Electric Modicon M340 GoAhead Webserver Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2015-7937)

Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data. This plugin only works with Tenable.ot. Please visit...

10CVSS6.3AI score0.07351EPSS
SaveExploits1References4
NCSC
NCSC
added 2024/02/15 12:0 a.m.5 views

Vulnerabilities fixed in Scheider Electric EcoStruxture and Modicon

Schneider Electric has fixed vulnerabilities in EcoStruxture and Modicon systems. A malicious party could exploit the vulnerabilities to cause a denial-of-service, or to bypass security measures, allowing the malicious party to affect the operation of PLC components. For successful misuse, the...

8.1CVSS6.9AI score0.00317EPSS
SaveExploits0
CNNVD
CNNVD
added 2024/02/14 12:0 a.m.8 views

Schneider Electric Modicon M340 Security Breach

The Schneider Electric Modicon M340 is a medium-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric, France. A security vulnerability exists in the Schneider Electric Modicon M340 that arises from improper message integrity enforcement durin...

8.1CVSS6.6AI score0.00317EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/02/14 12:0 a.m.7 views

Schneider Electric Modicon M340 Trust Management Issue Vulnerability

The Schneider Electric Modicon M340 is a mid-range PLC Programmable Logic Controller for industrial processes and infrastructure from Schneider Electric France. The Schneider Electric Modicon M340 is vulnerable to a trust management issue that arises from the use of hard-coded credentials, which...

7.7CVSS6.7AI score0.00232EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2024/02/14 12:0 a.m.7 views

Schneider Electric Modicon M340 Security Breach

The Schneider Electric Modicon M340 is a mid-range PLC programmable logic controller for industrial processes and infrastructure from Schneider Electric France. A security vulnerability exists in the Schneider Electric Modicon M340 that stems from insufficient credential protection and could lead...

7.1CVSS6.7AI score0.0015EPSS
SaveExploits0References3
BDU FSTEC
BDU FSTEC
added 2024/02/13 12:0 a.m.8 views

The vulnerabilities of the microprogramming software for Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58*S, and M580 CPU Safety BMEH58*S, as well as the programming tools EcoStruxure Control Expert and EcoStruxure Process Expert, allow a attacker to execute a “man-in-the-middle” attack.

The vulnerability of microprogrammed logic controllers PLCs from Schneider Electric, such as the Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, and M580 CPU Safety BMEH58S, as well as the PLC programming software EcoStruxure Control Expert and EcoStruxure Process...

8.1CVSS7.4AI score0.00317EPSS
SaveExploits0References2Affected Software4
Positive Technologies
Positive Technologies
added 2024/02/13 12:0 a.m.12 views

PT-2024-1606 · Schneider Electric · M580 Cpu Bmeh +4

Name of the Vulnerable Software and Affected Versions: Schneider Electric Modicon M340 CPU BMXP34, M580 CPU BMEP, M580 CPU BMEH, M580 CPU Safety BMEP58S, M580 CPU Safety BMEH58S versions affected versions not specified EcoStruxure Control Expert versions affected versions not specified EcoStruxur...

8.1CVSS7.3AI score0.00317EPSS
SaveExploits0References7
CISA
CISA
added 2023/07/20 12:0 p.m.11 views

CISA Releases One Industrial Control Systems Advisory

CISA released one Industrial Control Systems ICS advisory on July 20, 2023. This advisory provides timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-23-201-01 Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation...

7AI score
SaveExploits0References1
ICS
ICS
added 2023/07/20 6:0 a.m.51 views

Schneider Electric EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: EcoStruxure Products, Modicon PLCs, and Programmable Automation Controllers Vulnerabilities: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION...

9.8CVSS9.6AI score0.01163EPSS
SaveExploits0References10
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.18 views

Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7549)

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules see security notification for affected versions, that could cause denial of HTTP and FTP...

7.5CVSS5.7AI score0.01065EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.22 views

Schneider Electric Modicon Out-of-bounds Write (CVE-2021-22788)

A CWE-787: Out-of-bounds Write vulnerability exists that could cause denial of service when an attacker sends a specially crafted HTTP request to the web server of the device. Affected Product: Modicon M340 CPUs: BMXP34 Versions prior to V3.40, Modicon M340 X80 Ethernet Communication Modules:...

7.5CVSS7.4AI score0.01037EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.24 views

Schneider Electric Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200 Use of a Broken or Risky Cryptographic Algorithm (CVE-2018-7242)

Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks. This plugin only works with...

9.8CVSS8.4AI score0.01946EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.23 views

Schneider Electric Modicon M340 PLC Uncontrolled Resource Consumption (CVE-2017-6017)

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker...

7.8CVSS7.4AI score0.04807EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.22 views

Schneider Electric Modicon Cross-Site Request Forgery (CVE-2020-7534)

A CWE-352: Cross-Site Request Forgery CSRF vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in. Affected Products: Modicon M340 CPUs: BMXP34 All Versions, Modicon Quantum CPUs with...

8.8CVSS8AI score0.00358EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.20 views

Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7539)

A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules see security notification for affected versions, that could cause a denial of service...

7.5CVSS7.5AI score0.01181EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.26 views

Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7536)

A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs BMXP34 versions prior to V3.30 Modicon M340 Communication Ethernet modules BMXNOE0100 H versions prior to V3.4 BMXNOE0110 H versions prior to V6.6 BMXNOR0200H all versions, that could cause th...

7.8CVSS7.4AI score0.01155EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.17 views

Schneider Electric Modicon Exposure of Sensitive Information to an Unauthorized Actor (CVE-2019-6852)

A CWE-200: Information Exposure vulnerability exists in Modicon Controllers M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions, which could cause the disclosure of FTP...

7.5CVSS7.4AI score0.01379EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.15 views

Schneider Electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2018-7762)

A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-o...

7.5CVSS7.6AI score0.01315EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.15 views

Schneider Electric Modicon Improper Input Validation (CVE-2015-6461)

Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will resul...

5.5CVSS5.7AI score0.00871EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:0 a.m.21 views

Schneider Electric Modicon Use of Hard-coded Credentials (CVE-2019-6859)

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers All versions of the following CPUs and Communication Module product references listed in the Security Notifications, which could cause the disclosure of FTP hardcoded credentials when using the Web server of the...

7.5CVSS7.3AI score0.0115EPSS
SaveExploits0References2