Lucene search

K

Expert Security Vulnerabilities

cve
cve

CVE-2022-41668

A CWE-704: Incorrect Project Conversion vulnerability exists that allows adversaries with local user privileges to load a project file from an adversary-controlled network share which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1....

7.8CVSS

7.5AI Score

0.0004EPSS

2022-11-04 12:15 PM
31
4
cve
cve

CVE-2022-41667

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3...

7.8CVSS

7.5AI Score

0.0005EPSS

2022-11-04 12:15 PM
28
8
cve
cve

CVE-2022-41666

A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face...

7.8CVSS

7.5AI Score

0.0004EPSS

2022-11-04 05:15 AM
26
4
cve
cve

CVE-2022-40742

Mail SQR Expert system has a Local File Inclusion vulnerability. An unauthenticated remote attacker can exploit this vulnerability to execute arbitrary PHP file with .asp file extension under specific system paths, to access and modify partial system information but does not affect service...

6.5CVSS

6.7AI Score

0.001EPSS

2022-10-31 07:15 AM
22
3
cve
cve

CVE-2022-40741

Mail SQR Expert’s specific function has insufficient filtering for special characters. An unauthenticated remote attacker can exploit this vulnerability to perform arbitrary system command and disrupt...

9.8CVSS

9.6AI Score

0.003EPSS

2022-10-31 07:15 AM
28
cve
cve

CVE-2017-8371

Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified...

6.8CVSS

6.3AI Score

0.001EPSS

2022-10-03 04:23 PM
22
cve
cve

CVE-2022-37302

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and...

5.5CVSS

5.5AI Score

0.001EPSS

2022-09-13 10:15 AM
25
cve
cve

CVE-2022-37300

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of...

9.8CVSS

9.1AI Score

0.002EPSS

2022-09-12 06:15 PM
28
5
cve
cve

CVE-2022-26507

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828,...

9.8CVSS

9AI Score

0.012EPSS

2022-04-14 01:15 PM
47
cve
cve

CVE-2021-22797

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the...

7.8CVSS

7.7AI Score

0.002EPSS

2022-04-13 04:15 PM
39
cve
cve

CVE-2021-22795

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and...

9.8CVSS

9.8AI Score

0.004EPSS

2022-04-13 04:15 PM
31
cve
cve

CVE-2021-22794

A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and...

9.8CVSS

9.6AI Score

0.007EPSS

2022-04-13 04:15 PM
36
cve
cve

CVE-2022-24322

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data....

5.9CVSS

5.7AI Score

0.001EPSS

2022-03-09 11:15 PM
59
cve
cve

CVE-2022-24323

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product:...

5.9CVSS

5.7AI Score

0.001EPSS

2022-03-09 11:15 PM
58
cve
cve

CVE-2022-24319

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo....

5.9CVSS

5.7AI Score

0.001EPSS

2022-02-09 11:15 PM
45
cve
cve

CVE-2022-24320

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions),...

5.9CVSS

5.7AI Score

0.001EPSS

2022-02-09 11:15 PM
51
cve
cve

CVE-2022-24318

A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA...

7.5CVSS

7.5AI Score

0.001EPSS

2022-02-09 11:15 PM
58
cve
cve

CVE-2022-24321

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure...

7.5CVSS

7.5AI Score

0.001EPSS

2022-02-09 11:15 PM
69
cve
cve

CVE-2022-22807

A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert...

7.4CVSS

7.3AI Score

0.001EPSS

2022-02-09 11:15 PM
83
4
cve
cve

CVE-2022-22808

A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert...

8.8CVSS

8.8AI Score

0.001EPSS

2022-02-09 11:15 PM
63
2
cve
cve

CVE-2022-22804

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected....

5.4CVSS

5.3AI Score

0.001EPSS

2022-02-04 11:15 PM
159
cve
cve

CVE-2022-22727

A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power.....

8.8CVSS

8.4AI Score

0.002EPSS

2022-02-04 11:15 PM
53
5
cve
cve

CVE-2022-22726

A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and...

6.5CVSS

6.3AI Score

0.001EPSS

2022-02-04 11:15 PM
30
cve
cve

CVE-2021-22827

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior...

8.8CVSS

8.8AI Score

0.003EPSS

2022-01-28 08:15 PM
37
2
cve
cve

CVE-2021-22826

A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior...

8.8CVSS

8.8AI Score

0.003EPSS

2022-01-28 08:15 PM
39
cve
cve

CVE-2021-22790

A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP and BMEH, all versions), Modicon M340 CPU (part...

6.5CVSS

6.4AI Score

0.001EPSS

2021-09-02 05:15 PM
24
cve
cve

CVE-2021-22704

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that...

9.1CVSS

8.7AI Score

0.003EPSS

2021-09-02 05:15 PM
19
cve
cve

CVE-2021-22791

A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP and BMEH, all versions), Modicon M340 CPU (part...

6.5CVSS

6.4AI Score

0.001EPSS

2021-09-02 05:15 PM
20
cve
cve

CVE-2021-22792

A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP and BMEH, all versions), Modicon M340 CPU...

7.5CVSS

7.4AI Score

0.001EPSS

2021-09-02 05:15 PM
31
cve
cve

CVE-2021-22789

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers...

6.5CVSS

6.4AI Score

0.001EPSS

2021-09-02 05:15 PM
19
cve
cve

CVE-2021-22778

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

7.1CVSS

6.7AI Score

0.0005EPSS

2021-07-14 03:15 PM
31
3
cve
cve

CVE-2021-22781

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

5.5CVSS

5.5AI Score

0.0005EPSS

2021-07-14 03:15 PM
27
2
cve
cve

CVE-2021-22782

Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

5.5CVSS

5.3AI Score

0.0005EPSS

2021-07-14 03:15 PM
35
3
cve
cve

CVE-2021-22780

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all...

7.1CVSS

6.8AI Score

0.0005EPSS

2021-07-14 03:15 PM
24
5
cve
cve

CVE-2021-22779

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack.....

9.1CVSS

9AI Score

0.002EPSS

2021-07-14 03:15 PM
34
3
cve
cve

CVE-2021-22741

Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior), which could cause the revealing of account credentials when server database....

6.7CVSS

6.6AI Score

0.0005EPSS

2021-05-26 08:15 PM
29
4
cve
cve

CVE-2021-22705

Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine...

7.8CVSS

7.3AI Score

0.0005EPSS

2021-05-26 08:15 PM
37
4
cve
cve

CVE-2021-30176

The ZEROF Expert pro/2.0 application for mobile devices allows SQL Injection via the Authorization header to the /v2/devices/add...

9.8CVSS

9.8AI Score

0.002EPSS

2021-04-13 02:15 PM
18
cve
cve

CVE-2020-28221

A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the...

9.8CVSS

9.5AI Score

0.004EPSS

2021-01-26 06:15 PM
18
cve
cve

CVE-2018-18689

The Portable Document Format (PDF) specification does not provide any information regarding the concrete procedure of how to validate signatures. Consequently, a Signature Wrapping vulnerability exists in multiple products. An attacker can use /ByteRange and xref manipulations that are not...

5.3CVSS

5.7AI Score

0.002EPSS

2021-01-07 06:15 PM
32
cve
cve

CVE-2020-25179

GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the...

9.8CVSS

9.2AI Score

0.002EPSS

2020-12-14 05:15 PM
32
cve
cve

CVE-2020-25175

GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the...

9.8CVSS

9.3AI Score

0.002EPSS

2020-12-14 05:15 PM
25
cve
cve

CVE-2020-7560

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™...

8.6CVSS

8.7AI Score

0.001EPSS

2020-12-11 01:15 AM
40
1
cve
cve

CVE-2020-28219

A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from...

7.8CVSS

7.5AI Score

0.0005EPSS

2020-12-11 01:15 AM
35
2
cve
cve

CVE-2020-7546

A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user...

5.4CVSS

5.5AI Score

0.001EPSS

2020-12-01 03:15 PM
20
cve
cve

CVE-2020-7547

A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege...

8.8CVSS

8.6AI Score

0.001EPSS

2020-12-01 03:15 PM
20
cve
cve

CVE-2020-7545

A CWE-284:Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow for arbitrary code execution on the server when an authorized user access an affected...

7.2CVSS

7.3AI Score

0.001EPSS

2020-12-01 03:15 PM
25
cve
cve

CVE-2020-7559

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a...

7.5CVSS

7.4AI Score

0.001EPSS

2020-11-19 10:15 PM
33
cve
cve

CVE-2020-7544

A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal...

7.8CVSS

7.7AI Score

0.0005EPSS

2020-11-19 10:15 PM
42
1
cve
cve

CVE-2020-7538

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted...

7.5CVSS

7.5AI Score

0.001EPSS

2020-11-19 10:15 PM
28
Total number of security vulnerabilities186