Lucene search

K
cve[email protected]CVE-2021-22780
HistoryJul 14, 2021 - 3:15 p.m.

CVE-2021-22780

2021-07-1415:15:08
CWE-522
web.nvd.nist.gov
23
5
cve-2021-22780
insufficiently protected credentials
ecostruxure control expert
ecostruxure process expert
scadapack remoteconnect
unauthorized access
password protection

3.6 Low

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:L/AC:L/Au:N/C:P/I:P/A:N

7.1 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

6.8 Medium

AI Score

Confidence

High

0.0005 Low

EPSS

Percentile

17.3%

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.

Affected configurations

NVD
Node
schneider-electricecostruxure_control_expertRange<15.0
OR
schneider-electricecostruxure_control_expertMatch15.0-
OR
schneider-electricecostruxure_process_expert
OR
schneider-electricremoteconnectscadapack_x70

CNA Affected

[
  {
    "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions",
    "vendor": "n/a",
    "versions": [
      {
        "status": "affected",
        "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions"
      }
    ]
  }
]

Social References

More

3.6 Low

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:L/AC:L/Au:N/C:P/I:P/A:N

7.1 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

6.8 Medium

AI Score

Confidence

High

0.0005 Low

EPSS

Percentile

17.3%

Related for CVE-2021-22780