Lucene search
K

CVE-2020-25175

🗓️ 14 Dec 2020 16:36:24Reported by icscertType 
cve
 cve
🔗 web.nvd.nist.gov👁 69 Views

GE Healthcare Imaging and Ultrasound Products expose credentials during network transport

Related
Detection
Affected
Refs
ReporterTitlePublishedViews
Family
Circl
CVE-2020-25175
14 Dec 202020:39
circl
CNNVD
General Electric Healthcare Imaging and General Electric Healthcare Ultrasound Security Vulnerabilities
8 Dec 202000:00
cnnvd
Cvelist
CVE-2020-25175
14 Dec 202016:36
cvelist
EUVD
EUVD-2020-17866
7 Oct 202500:30
euvd
NVD
CVE-2020-25175
14 Dec 202017:15
nvd
Prion
Code injection
14 Dec 202017:15
prion
RedhatCVE
CVE-2020-25175
22 May 202515:55
redhatcve
ThreatPost
Critical, Unpatched Bug Opens GE Radiological Devices to Remote Code Execution
8 Dec 202017:00
threatpost
NVD
Vulners
[
  {
    "product": "GE Healthcare Imaging and Ultrasound Products",
    "vendor": "n/a",
    "versions": [
      {
        "status": "affected",
        "version": "MR 3.0T Signa HDxt / 3.0T Signa HDx, versions HD 16, HD23 1.5T Brivo MR355 / Optima MR360, versions SV20.1, SV23.0 1.5T Signa HDx / 1.5T Signa HDx, Signa HDi / Signa VIBRANT, versions HD16, HD23 Ultrasound, General Imaging LOGIQ 5 [BT03], LOGIQ 7 (BT03, BT04, BT06], LOGIQ 9 [BT02, BT03, BT04, BT06] Ultrasound, Cardiovascular Vivid I [BT06], Vivid 7 {BT02-BT06], EchoPAC (Turnkey) [BT06], Image Vault (Turnkey) [4.3] Ultrasound, Women’s Health Voluson 730 [BT05, BT08] Advanced Visualization AW 4.0 to AW 4.6, AWS2.0 to AW3.0, Interventional Innova 2000, 3100, 4100, 2100-IQ, 3100-IQ, 4100-IQ, 212-IQ, 313-IQ Optima 320, CL320i, CL323i, CL320, 3100 Optima IGS 320, 330"
      },
      {
        "status": "affected",
        "version": "Innova IGS 5x0, 6x0, 7x0 Advanced Visualization AW 4.0 to AW 4.6, AWS2.0 to AW3.0 X-Ray Brivo XR118, XR383, XR515, XR575"
      },
      {
        "status": "affected",
        "version": "Definium 5000, 6000, 8000, AMX 700"
      },
      {
        "status": "affected",
        "version": "Discovery XR650, XR656, XR656+"
      },
      {
        "status": "affected",
        "version": "Optima XR640, XR646, XR220amx, XR200amx"
      },
      {
        "status": "affected",
        "version": "Precision 500D, WDR1 Mammography Seno 200D, DS, Essential"
      },
      {
        "status": "affected",
        "version": "Senographe Pristina Computed Tomography BrightSpeed Elite, Elite Select, Edge, Edge Select Brivo CT385 Discovery CT590RT, CT750HD LightSpeed VCT, Pro16, RT16 Optima Advance, CT520, CT540, CT660, CT580, CT580RT, CT580W, CT670, CT680 Quantum, Expert & Professional Revolution EVO,HD,ACT, ACTs, CT, Discovery CT, Frontier, Frontier ES Nuclear Medicine, PET/CT Brivo NM 615 Discovery NM 630, NM 750b, NM D530c, NM/CT D570c, NM/CT 670 Infinia Discovery NM830, NM/CT 860, NM/CT850, NM/CT 870,"
      }
    ]
  }
]

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

21 Nov 2024 05:17Current
9.3High risk
Vulners AI Score9.3
CVSS 25
CVSS 3.19.8
EPSS0.00235
69