Lucene search
+L

Siemens SCALANCE and RUGGEDCOM Out-of-bounds Read (CVE-2025-9086)

🗓️ 10 Feb 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 5 Views

Siemens SCALANCE and Ruggedcom CVE-2025-9086 cookie handling bug may override a secure cookie via HTTP.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(505135);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/03/05");

  script_cve_id("CVE-2025-9086");
  script_xref(name:"ICSA", value:"26-043-06");

  script_name(english:"Siemens SCALANCE and RUGGEDCOM Out-of-bounds Read (CVE-2025-9086)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"1. A cookie is set using the `secure` keyword for `https://target` 2.
curl is redirected to or otherwise made to speak with `http://target`
(same    hostname, but using clear text HTTP) using the same cookie
set 3. The same cookie name is set - but with just a slash as path
(`path='/'`).    Since this site is not secure, the cookie *should*
just be ignored. 4. A bug in the path comparison logic makes curl read
outside a heap buffer    boundary  The bug either causes a crash or it
potentially makes the comparison come to the wrong conclusion and lets
the clear-text site override the contents of the secure cookie,
contrary to expectations and depending on the memory contents
immediately following the single-byte allocation that holds the path.
The presumed and correct behavior would be to plainly ignore the
second set of the cookie since it was already set as secure on a
secure host so overriding it on an insecure host should not be okay.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://cert-portal.siemens.com/productcert/html/ssa-089022.html");
  script_set_attribute(attribute:"see_also", value:"https://support.industry.siemens.com/cs/ww/en/view/109997626/");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-043-06");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-9086");

  script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"true");
  script_cwe_id(125);

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/09/12");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/01/28");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/02/10");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xch328_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm324_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm328_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xcm332_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-300_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xc-400_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500wg_series_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:siemens:scalance_xr-500_series_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Siemens");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Siemens');

var asset = tenable_ot::assets::get(vendor:'Siemens');

var vuln_cpes = {
    "cpe:/o:siemens:ruggedcom_rst2428p_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "RuggedCom", "orderNumbers" : ['6GK6242-6PA00']},
    "cpe:/o:siemens:scalance_xch328_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2EC2']},
    "cpe:/o:siemens:scalance_xcm324_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5324-8TS01-2AC2']},
    "cpe:/o:siemens:scalance_xcm328_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5328-4TS01-2AC2']},
    "cpe:/o:siemens:scalance_xrh334_%2824_v_dc%2c_8xfo%2c_cc%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2ER3']},
    "cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_12xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%28230_v_ac%2c_8xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%28230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-3AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_12xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824_v_dc%2c_8xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%2824v_dc%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-2AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_12xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-3TS01-4AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230_v_ac%2c_8xfo%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-2TS01-4AR3']},
    "cpe:/o:siemens:scalance_xrm334_%282x230v_ac%2c_2x10g%2c_24xsfp%2c_8xsfp%2b%29_firmware:3.3" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5334-5TS01-4AR3']},
    "cpe:/o:siemens:scalance_xcm332_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300", "orderNumbers" : ['6GK5332-0GA01-2AC2']},
    "cpe:/o:siemens:scalance_xc-300_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xr-300_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX300"},
    "cpe:/o:siemens:scalance_xc-400_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX400"},
    "cpe:/o:siemens:scalance_xr-500wg_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"},
    "cpe:/o:siemens:scalance_xr-500_series_firmware" :
        {"versionEndExcluding" : "3.3", "family" : "SCALANCEX500"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

05 Mar 2026 00:00Current
6.7Medium risk
Vulners AI Score6.7
CVSS 3.17.5
EPSS0.01301
SSVC
5